3
INDUSTRIAL TEMPERATURE RANGE
IDT74CBTLVR3384
LOW-VOLTAGE 10-BIT BUS SWITCH
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Condition: TA = –40°C to +85°C
NOTES:
1. Typical values are at 3.3V, +25°C ambient.
2. The increase in supply current is attributable to each input that is at the specified voltage level rather than VCC or GND.
3. This is measured by the voltage drop between the A and B terminals at the indicated current through the switch. On-state resistance is determined by the lower of the voltages
of the two (A or B) terminals.
Symbol Parameter Test Conditions Min. Typ.(1) Max. Unit
VIK Control Inputs, Data I/O VCC = 3V, II = –18mA — — –1.2 V
IIControl Inputs VCC = 3.6V, VI = VCC or GND — — ±1 µA
IOZ Data I/O VCC = 3.6V, VO = 0V or 3.6V switch disabled — — 5 µA
IOFF VCC = 0V, VI or VO = 0V to 3.6V — — 50 µA
ICC VCC = 3.6V, IO = 0, VI = VCC or GND — — 10 µA
∆ICC(2) Control Inputs VCC = 3.6V, one input at 3V, other inputs at VCC or GND — — 3 0 0 µA
CIControl Inputs VI = 3V or 0 — 4 — pF
CIO(OFF) VO = 3V or 0, OE = VCC —7—pF
Max. at VCC = 2.3V VI = 0 IO = 64mA — 30 47
Typ. at VCC = 2.5V IO = 24mA — 30 47
RON(3) VI = 1.7V IO = 15mA — 36 80 Ω
VI = 0 IO = 64mA — 30 42
VCC = 3V IO = 24mA — 30 42
VI = 2.4V IO = 15mA — 32 47
VCC = 2.5V ± 0.2V VCC = 3.3V ± 0.3V
Symbol Parameter Min. Max. Min. Max. Unit
tPD(1) Propagation Delay —0.9 —1.5 ns
A to B or B to A
tEN Output Enable Time 1 6 1 5.3 ns
OE to A or B
tDIS Output DisableTime 1 5.5 1 5.5 ns
OE to A or B
NOTE:
1 . The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and the specified load capacitance when driven by an ideal voltage source
(zero output impededance).
SWITCHING CHARACTERISTICS