USA 858 674 8100
Germany 49 7032 7806 0
Singapore 65 6287 8998
Shanghai
86 21 54643211 / 2
China 86 755 33966678
Taiwan 886 3 4641811
www.pulseeng.com
109 SPM2007 (11/07)
SMT CURRENT SENSE
TRANSFORMERS
PA0368NL Series
Mechanical Schematic
.090
2,28
.016
0,40
.006/0,15
4 SURFACES
.053
1,35
.124
3,15
.236
6,00
.236
6,00 .040 ± .002
1,00 ± 0,05
Ø
PA0368.XXX
Date Code
Cntry of Origin
.128
3,25
.285
7,25
.325
8,25
21
34
Isecondary
Vref
RT
N
1
Iprimary
APPLICATION CIRCUIT
3
1
4
2
1T
Weight . . . . . . . . . . . . . .0.3 grams
Tape & Reel . . . . . . . . . . .1100/reel
Dimensions: Inches
mm
Unless otherwise specified, all tolerances are ± .010
0,25
Electrical Specifications @ 25°C — Operating Temperature -40°C to 130°C 6
Secondary DCR (mΩMAX) Hipot
Part Number
4,5
Turns ratio Current Rating
1
Inductance Primary Secondary (V
RMS
)
(mH MIN)
PA0368.050NL 1:50 4 1.7 4 900 500
PA0368.070NL 1:70 4 3.3 4 1200 500
PA0368.080NL 1:80 4 4.3 4 1400 500
PA0368.100NL 1:100 4 6.7 4 1600 500
PA0368.125NL 1:125 4 10.4 4 1900 500
Height: 3.3mm Max
Footprint: 8.4mm x 8.4mm Max
Current Rating: up to 4A
Frequency Range: 50kHz to 1MHz
NOTES:
1. The maximum current rating is based on temperature rise of the component
and represents the DC current which will cause a typical temperature rise
of 40°C with no airflow.
2. To calculate the value of the terminating resistor (Rt) use the following
formula: Rt (Ω) = V
REF
* N / (Ipeak primary)
3.
The peak flux density of device must remain below 2000 Gauss.
To calculate the peak flux density for a uni-polar current, use the following
formula:
Bpk = 64.9 * V
REF
* (Duty Cycle Max) * 10
5
/ (N * Freq kHz)
*for bi-polar current applications divide Bpk (as calculated above) by 2.
4. Optional Tape & Reel packaging can be ordered by adding
a "T" suffix to the part number (i.e. PA0368.050NL becomes
PA0368.050NLT). Pulse complies to industry standard tape and
reel specification EIA481.
5. The "NL" suffix indicates an RoHS-compliant part number. Non-NL
suffixed parts are not necessarily RoHS compliant, but are electri-
cally and mechanically equivalent to NL versions. If a part number
does not have the "NL" suffix, but an RoHS compliant version is
required, please contact Pulse for availability.
6. The temperature of the component (ambient plus temperature rise)
must be within the stated operating temperature range.