Nov 7, 2006 Page 1 of 4 www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
HP6 Multi-Output AC-DC Front End
RACK-HP600
HP6 and RACK-HP600 Features
Compact 1U design
N+1 redundancy with hot plug capability
Up to four individually regulated outputs
I
2C interface with interrupt capability
Hot swap with low insertion/extraction f orce connector
Power factor corrected
No minimum load required
5 V @ 1 A standby output
Single-wire current sharing
Self-contained ORing Diodes
Current limit and over-voltage protection
Full power up to 50º C
TUV, cTUVus & CB report
600 watts per module
Ac input with PFC
Description
The HP6 provides up to 600 Watts total output power with one to four outputs ranging from 0.8 to 12 Volts. HP600
RACKS offer hot-plug capability for up to 1200 Watts total at low line (2 +1) or 1800 Watts total at high line. Three
separate multi output power supplies are internally paralleled and will automatically current share for load
distribution. Hot-swap modules can b e replaced with no system downtime.
V1 V2 V3 V4
HP6 Front End Models Volts Amps Volts Amps Volts Amps Volts Amps
HP6-X8X8D2D-O X 80 X 80 12 20 -12 3
HP6-X4X8D4D-O X 40 X 80 12 40 -12 3
HP6-X8X4D4D-O X 80 X 40 12 40 -12 3
HP6-X8X4D2D-O X 80 X 40 12 20 -12 3
HP6-X4X8D2D-O X 40 X 80 12 20 -12 3
HP6-X4X4D4D-O X 40 X 40 12 40 -12 3
RACK-HP600 Designations
RACK-HP600 X 240 X 120 12 120 -12 9
Output Voltage X = A (2.0V); B (3.3V); C (5V); T (2.5V); V (1.8V); W (1.5V); X (1.2V); Y (1V); Z (0.8V)
Options O = B (I2C); M (Output power good – TTL high); N (Power fail – TTL high); R (Reverse airflow)
Please contact Power-One for additional model combinations.
Nov 7, 2006 Page 2 of 4 www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
Input Specifications
Input voltage range: 85 to 264 Vac, 47 to 63 Hz
Power Factor: 0.99 at full load and nominal line
Inrush Current: 40 A peak hot and cold start
Input Protection: Internal 15 A line fuse
Output Specifications
Output Power: 600 W maximum
Overshoot/Undershoot: Less than 1% at turn-on or turn-
off. Less than 3% for 50% to 100% load step.
Start-Up Time: Less than 2 seconds
Efficiency: 78% typical measured at full load, nominal input
Hold-up Time: 20 ms minimum at full load and low line
Single Wire Current Share (V1, V2 and +12V): 10% full
load rating.
Load Regulation: 0.5% with remote sense, 2% without
Line Regulation: 0.1% over entire operating range
Cross Regulation: Less than 0.5%
Minimum Load: No minimum load required
Overcurrent Protection: All outputs set to 115-135% of full
rated load with automatic recovery
Overtemperature Prot ection: Automatic shutdown with
auto recovery.
Remote Sense: Compensates for voltage drop of up to 0.5
V to the load (V1, V2, and +12V). Shorted sense lead
protection.
Overvoltage Protection: All outputs set at 115%-135% of
nominal. Reset by cycling input power.
Output Noise and Ripple: PARD: 1% or 50 mV p-p,
whichever is greater, measured at 20 Mhz bandwidth.
Mechanical Specifications
Size: 1.6” H x 5” W x 11.5” D
Input Connector: Front panel IEC
Output Connector: FCI power blade
MTBF: 250,000 hours calculated at 25 °C, Bellcore
Standard
Warranty: Two years from date of shipment, standard
product only.
Specifications are subject to change without prior notice.
Signals and Controls
LED Output Good Indicator: Front panel green LED indicates
power supply is good; amber indic ates fau lt.
LED AC Good Indicator: Front panel green LED indicates
Ac input voltage is present and above minimum level.
Output Good Signal*: TTL compatible signal, normally high.
Goes low when power supply is out of specified range.
Power Fail Signal*: TTL compatible signal, normally high
(indicating Vin is present and above minimum level).
Enable*: Normally TTL High, drive low to enable.
*All interface signals are TTL compatible
I2C Interface
Event Driven Messag es:
• Notification of fan speed abnormality
• Output voltage under specified ‘g ood’ range
• Output voltage over specified ‘good’ ra nge (software OVP)
• Temperature abnormalities
Sensor Device Commands:
• Get voltage readings
• Get temperature readings
• Get fan speed readings
FRU (Field Replaceable Unit) Information Storage:
• Manufacturer’s name
• Product name
• Product part/model number
• Product version/revision
• Product serial number
Safety & Environm ental
Operating Temperature: 0 to 50°C
Storage Temperatur e: -40°C to +85°C
Operating Humidity: Maximum 95% RH non-condensing
Operating Altitude: 10,000 feet
Non-operating Altitude: 40,000 feet
Temperature Coefficient: 0.02% per °C within rated load
Safety Agency Compliance: TUV, cTUVus & CB report
EMI: Meets EN55022, Class B
Harmonic Suppression: Meets EN6100-3-2
Input Transient Protection:
Electrostatic Discharge: EN61000-4-2, Criteria B
Radiated, Radio-Frequency, Electromagnetic Field:
EN61000-4-3, Criteria A
Electrical Fast Transients/Burst: EN61000-4-4, Criteria B
Voltage Fluctuations and Flic kers: EN61000-3-3, Criteria B
Surge Test: EN61000-4-5, Cr iteria B
Conducted Immunity: EN61000-4- 6, Criteria A
Dielectric Withstand:
Input-to-ground: 2200 Vdc
Input-to-output: 4300 Vdc
Output-to-case: 25 Vdc
Ac Leakage Current: 1.2mA maximum at 240 Vac, 50 Hz
Nov 7, 2006 Page 3 of 4 www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
HP6 Outline Drawings and Dimension s
HP6 Connector Pin Descriptions
HP6 PIN Numbers and Signal Names
1 Ground 18 Share V2
2 Ground 19 +Sense V2
3 V2 Output 20 SDA
4 V2 Output 21 SCL
5 V2 Output 22 Share V3
6 Ground 23 Power Fail OK
7 Ground 24 5V Standby
8 Ground 25 5V Standby
9 V1 Output 26 +Sense V3
10 V1 Output 27 Power OK
11 V1 Output 28 Present
12 Dc Enable 29 A0
13 A1 30 Interrupt
14 -Sense 31 Share V1
15 +Sense V1 32 Ground
16 V4 Output (-12V) 33 V3 Output (+12V)
17 V4 Output (-12V) 34 V3 Output (+12V)
HP6 J5 Connector Detail
Nov 7, 2006 Page 4 of 4 www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
RACK-HP600 Outline Dra wings and Dimensions
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.