Nov 7, 2006 Page 2 of 4 www.power-one.com
Multi-Output HP6 Front End
and RACK-HP600 Data Sheet
Input Specifications
Input voltage range: 85 to 264 Vac, 47 to 63 Hz
Power Factor: 0.99 at full load and nominal line
Inrush Current: 40 A peak hot and cold start
Input Protection: Internal 15 A line fuse
Output Specifications
Output Power: 600 W maximum
Overshoot/Undershoot: Less than 1% at turn-on or turn-
off. Less than 3% for 50% to 100% load step.
Start-Up Time: Less than 2 seconds
Efficiency: 78% typical measured at full load, nominal input
Hold-up Time: 20 ms minimum at full load and low line
Single Wire Current Share (V1, V2 and +12V): 10% full
load rating.
Load Regulation: 0.5% with remote sense, 2% without
Line Regulation: 0.1% over entire operating range
Cross Regulation: Less than 0.5%
Minimum Load: No minimum load required
Overcurrent Protection: All outputs set to 115-135% of full
rated load with automatic recovery
Overtemperature Prot ection: Automatic shutdown with
auto recovery.
Remote Sense: Compensates for voltage drop of up to 0.5
V to the load (V1, V2, and +12V). Shorted sense lead
protection.
Overvoltage Protection: All outputs set at 115%-135% of
nominal. Reset by cycling input power.
Output Noise and Ripple: PARD: 1% or 50 mV p-p,
whichever is greater, measured at 20 Mhz bandwidth.
Mechanical Specifications
Size: 1.6” H x 5” W x 11.5” D
Input Connector: Front panel IEC
Output Connector: FCI power blade
MTBF: 250,000 hours calculated at 25 °C, Bellcore
Standard
Warranty: Two years from date of shipment, standard
product only.
Specifications are subject to change without prior notice.
Signals and Controls
LED Output Good Indicator: Front panel green LED indicates
power supply is good; amber indic ates fau lt.
LED AC Good Indicator: Front panel green LED indicates
Ac input voltage is present and above minimum level.
Output Good Signal*: TTL compatible signal, normally high.
Goes low when power supply is out of specified range.
Power Fail Signal*: TTL compatible signal, normally high
(indicating Vin is present and above minimum level).
Enable*: Normally TTL High, drive low to enable.
*All interface signals are TTL compatible
I2C Interface
Event Driven Messag es:
• Notification of fan speed abnormality
• Output voltage under specified ‘g ood’ range
• Output voltage over specified ‘good’ ra nge (software OVP)
• Temperature abnormalities
Sensor Device Commands:
• Get voltage readings
• Get temperature readings
• Get fan speed readings
FRU (Field Replaceable Unit) Information Storage:
• Manufacturer’s name
• Product name
• Product part/model number
• Product version/revision
• Product serial number
Safety & Environm ental
Operating Temperature: 0 to 50°C
Storage Temperatur e: -40°C to +85°C
Operating Humidity: Maximum 95% RH non-condensing
Operating Altitude: 10,000 feet
Non-operating Altitude: 40,000 feet
Temperature Coefficient: 0.02% per °C within rated load
Safety Agency Compliance: TUV, cTUVus & CB report
EMI: Meets EN55022, Class B
Harmonic Suppression: Meets EN6100-3-2
Input Transient Protection:
Electrostatic Discharge: EN61000-4-2, Criteria B
Radiated, Radio-Frequency, Electromagnetic Field:
EN61000-4-3, Criteria A
Electrical Fast Transients/Burst: EN61000-4-4, Criteria B
Voltage Fluctuations and Flic kers: EN61000-3-3, Criteria B
Surge Test: EN61000-4-5, Cr iteria B
Conducted Immunity: EN61000-4- 6, Criteria A
Dielectric Withstand:
Input-to-ground: 2200 Vdc
Input-to-output: 4300 Vdc
Output-to-case: 25 Vdc
Ac Leakage Current: 1.2mA maximum at 240 Vac, 50 Hz