AT24C16D [DATASHEET]
Atmel-8906F-SEEPROM-AT24C16D-Datasheet_012017
4
3. Device Operation and Communication
The AT24C16D operates as a slave device and utilizes a simple I2C-compatible 2-Wire digital serial interface to
communicate with a host controller, commonly referred to as the bus Master. The Master initiates and controls
all Read and Write operations to the slave devices on the serial bus, and both the Master and the slave devices
can transmit and receive data on the bus.
The serial interface is comprised of just two signal lines: Serial Clock (SCL) and Serial Data (SDA). The SCL pin
is used to receive the clock signal from the Master, while the bidirectional SDA pin is used to receive command
and data information from the Master as well as to send data back to the Master. Data is always latched into the
AT24C16D on the rising edge of SCL and always output from the device on the falling edge of SCL. Both the
SCL and SDA pin incorporate integrated spike suppression filters and Schmitt Triggers to minimize the effects of
input spikes and bus noise.
All command and data information is transferred with the Most-Significant Bit (MSB) first. During bus
communication, one data bit is transmitted every clock cycle, and after eight bits (one byte) of data have been
transferred, the receiving device must respond with either an Acknowledge (ACK) or a No-acknowledge (NACK)
response bit during a ninth clock cycle (ACK/NACK clock cycle) generated by the Master. Therefore, nine clock
cycles are required for every one byte of data transferred. There are no unused clock cycles during any Read or
Write operation, so there must not be any interruptions or breaks in the data stream during each data byte
transfer and ACK or NACK clock cycle.
During data transfers, data on the SDA pin must only change while SCL is low, and the data must remain stable
while SCL is high. If data on the SDA pin changes while SCL is high, then either a Start or a Stop condition will
occur. Start and Stop conditions are used to initiate and end all serial bus communication between the Master
and the slave devices. The number of data bytes transferred between a Start and a Stop condition is not limited
and is determined by the Master. In order for the serial bus to be idle, both the SCL and SDA pins must be in the
logic-high state at the same time.
3.1 Clock and Data Transition Requirements
The SDA pin is an open drain terminal and therefore must be pulled high with an external pull-up resistor. Data
on the SDA pin may change only during SCL low time periods. Data changes during SCL high periods will
indicate a Start or Stop condition as defined below.
3.2 Start and Stop Conditions
3.2.1 Start Condition
A Start condition occurs when there is a high-to-low transition on the SDA pin while the SCL pin is at a stable
Logic 1 state and will bring the device out of standby mode. The Master uses a Start condition to initiate any
data transfer sequence; therefore, every command must begin with a Start condition. The device will
continuously monitor the SDA and SCL pins for a Start condition but will not respond unless one is detected.
Please refer to Figure 3-1 for more details.
3.2.2 Stop Condition
A Stop condition occurs when there is a low-to-high transition on the SDA pin while the SCL pin is stable in the
Logic 1 state. The Master can use the Stop condition to end a data transfer sequence with the AT24C16D which
will subsequently return to standby mode. The Master can also utilize a repeated Start condition instead of a
Stop condition to end the current data transfer if the Master will perform another operation. Please refer to
Figure 3-1 for more details.