Rev.02.16.07
NFS50_7608J
2 of 4
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Specifications
OUTPUT SPECIFICATIONS
Voltage adjustability +5V output ±3%
+12V tracks the 5V output
Line regulation LL to HL at max. load ±0.3%
Total regulation Main output (output 1) ±2.5%
All other outputs ±5.0%
(See Notes 5, 6)
Overshoot/undershoot At turn-on 0%
Transient response 5V (2.5A to 5A) 500mV max. dev.
500μs recovery to 0.5%
12V (1A to 2A) 300mV max. dev.
500μs recovery to 0.5%
Temperature coefficient All outputs ±0.03%/°C, max.
Overvoltage protection +5V output 6.25V ±0.65V
Output power limit Primary power 90W Pin max.
limited 60W Pout min.
Short circuit protection Yes, with auto-restart
INPUT SPECIFICATIONS
Input voltage range Universal input 85 to 264VAC
120 to 370VDC
Input frequency range 47 to 440Hz
Input surge current 110VAC, cold start 10A, max.
230VAC, cold start 20A max.
Safety ground 132VAC, 60Hz 0.2mA, max.
leakage current 264VAC, 50Hz 0.4mA, max.
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15 Level A
Radiated emissions EN55022, FCC part 15 Level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
EMC CHARACTERISTICS
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 2
Radiated immunity EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity EN61000-4-6, level 3 Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time 110VAC, 50W output power 16ms
230VAC, 50W output power 100ms
Efficiency 70%, typ.
Isolation voltage Input/output 3000VAC
Input/chassis 1500VAC
Switching frequency Variable 25kHz to 250kHz
Approvals and VDE0805, EN60950, IEC950
standards IEC1010, CSA C22.2 No. 950
Weight 400g (14oz)
MTBF (See Note 7) MIL-HDBK-217E, 25°C 160,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating range 0°C to +70°C
(See derating curve)
Non-operating –40°C to +85°C
0°C to 50°C ambient temp., 50W
Convection cooled
0°C to 50°C ambient, 60W
Forced air @ 20 CFM
50°C to 70°C ambient Derate linearly
to 50% load
Peak (30 seconds) 60W
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 9) 5Hz to 500Hz 2.4G rms (approx)