The NFS50 series is a 50W universal input AC/DC power supply on
a 6.3 x 3.94 inch card with a maximum component height of 1.5
inches for use in 1U applications. The NFS50 series can regulate on
the auxiliary outputs down to no load making it suitable for
applications that require a heavy logic load on the main 5V output
and low nominal loads with high peak capability for drives, relays
or switches on the auxiliary outputs. The NFS50 provides 50W of
output power with free air convection cooling which can be
boosted to 60W with 20CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full
international safety approval and the CE mark, meets conducted
emissions EN55022 level A. The NFS50 series is designed for use
in low power data networking, computer, telecom and industrial
applications such as POS terminals, servers, PABX's, industrial PC's
and process automation.
Embedded Power for
Business-Critical Continuity
NFS50_7608J
Triple output
Special Features
• 6.3 x 3.94 x 1.5 inch package
(1U applications)
• Overvoltage and
short circuit protection
• 50W with free
air convection cooling
• Regulation to no load
• Isolated output option
• EN55022, EN55011
conducted emissions level A
• UL, VDE and CSA
safety approvals
• NFS50 Medical IEC601
approved
• Available RoHS compliant
• 2 year warranty
Total Power: 50 - 60W
Input Voltage: 85 - 264VAC
120 - 370VDC
# of Outputs: Triple
Safety
VDE0805/EN60950/
IEC950/IEC1010
File No. 10401-3336-1036
Licence No 1485 and 1650
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
Rev.02.16.07
NFS50_7608J
1 of 4
Rev.02.16.07
NFS50_7608J
2 of 4
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Specifications
OUTPUT SPECIFICATIONS
Voltage adjustability +5V output ±3%
+12V tracks the 5V output
Line regulation LL to HL at max. load ±0.3%
Total regulation Main output (output 1) ±2.5%
All other outputs ±5.0%
(See Notes 5, 6)
Overshoot/undershoot At turn-on 0%
Transient response 5V (2.5A to 5A) 500mV max. dev.
500μs recovery to 0.5%
12V (1A to 2A) 300mV max. dev.
500μs recovery to 0.5%
Temperature coefficient All outputs ±0.03%/°C, max.
Overvoltage protection +5V output 6.25V ±0.65V
Output power limit Primary power 90W Pin max.
limited 60W Pout min.
Short circuit protection Yes, with auto-restart
INPUT SPECIFICATIONS
Input voltage range Universal input 85 to 264VAC
120 to 370VDC
Input frequency range 47 to 440Hz
Input surge current 110VAC, cold start 10A, max.
230VAC, cold start 20A max.
Safety ground 132VAC, 60Hz 0.2mA, max.
leakage current 264VAC, 50Hz 0.4mA, max.
EMC CHARACTERISTICS
Conducted emissions EN55022, FCC part 15 Level A
Radiated emissions EN55022, FCC part 15 Level A
ESD air EN61000-4-2, level 3 Perf. criteria 1
EMC CHARACTERISTICS
ESD contact EN61000-4-2, level 4 Perf. criteria 1
Surge EN61000-4-5, level 3 Perf. criteria 1
Fast transients EN61000-4-4, level 3 Perf. criteria 2
Radiated immunity EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity EN61000-4-6, level 3 Perf. criteria 2
GENERAL SPECIFICATIONS
Hold-up time 110VAC, 50W output power 16ms
230VAC, 50W output power 100ms
Efficiency 70%, typ.
Isolation voltage Input/output 3000VAC
Input/chassis 1500VAC
Switching frequency Variable 25kHz to 250kHz
Approvals and VDE0805, EN60950, IEC950
standards IEC1010, CSA C22.2 No. 950
Weight 400g (14oz)
MTBF (See Note 7) MIL-HDBK-217E, 25°C 160,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating range 0°C to +70°C
(See derating curve)
Non-operating –40°C to +85°C
0°C to 50°C ambient temp., 50W
Convection cooled
0°C to 50°C ambient, 60W
Forced air @ 20 CFM
50°C to 70°C ambient Derate linearly
to 50% load
Peak (30 seconds) 60W
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 9) 5Hz to 500Hz 2.4G rms (approx)
Rev.02.16.07
NFS50_7608J
3 of 4
Embedded Power for
Business-Critical Continuity
Specifications Contd.
Notes
1 Convection cooled, maximum 50W output power.
2 Peak outputs lasting less than 30 seconds with duty factor less than 10%.
During peak loading output may go outside total regulation limits. Maximum
output during peak loading is 60 Watts.
3 Forced air, 20 CFM at 1 atmosphere.
4 Figure is peak-to-peak. Output noise measurements are across a 50MHz
bandwidth made using a 12” twisted pair, terminated with a 47μF capacitor.
5 Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits and output voltages adjusted
to their factory settings. Also, for stated I(2) regulation: I(1)/I(2)≤5.
6 A minimum load of 0.5 Amps is required on the +5.1V output to obtain full
current from the -12V output.
7 Derating curve is application specific for ambient temperatures > 50°C, for
optimum reliability no part of the heatsink should exceed 110oC and no
semiconductor case temperature should exceed 115oC.
8 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
9 Three orthogonal axes, random vibration, ten minute test for each axis.
10 A 5 Watt minimum load is recommended to achieve design MTBF.
11 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
12 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE
RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
OUTPUT OUTPUT CURRENTS RIPPLE (4) TOTAL MODEL
VOLTAGE MAX(1) PEAK (2) FAN (3) REGULATION(5,6) NUMBER (12)
+5.1V (I1) (6) 5.0A 7.0A 7.0A 50mV ±2.5% NFS50-7608J
+12.0V (I2) 2.0A 5.0A 2.5A 120mV ±5.0%
-12.0V 0.5A 1.0A 0.7A 120mV ±5.0%
AC mating connector
Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp
terminal.
DC mating connector
Molex 22-01-1043 or equivalent with Molex
08-50-0031 or equivalent crimp terminal.
ALL DIMENSIONS ARE IN INCHES (mm)
Maximum component height is 1.5 (38.1)
3.15
(80.0)
0.40
(10.2)
4.80
(121.9)
3.94
(100.1)
0.75
(19.0)
6.30
(160.0)
J2
J3
J4
J1 E1
OUTPUT
ADJUST
0.156 (3.96) Dia. 4 Places
MAX HEIGHT 38.1mm PIN1
PIN1
PIN1
2
1
60W
50W
20 CFM FORCED AIR COOLING
25W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
DERATING CURVE
Output Power (Watts)
5W MINIMUM LOAD REQUIRED TO ACHIEVE DESIGN MTBF
NATURAL
CONVECTION
COOLING
30W
PIN CONNECTIONS
J1 NFS50-7608J
Pin 1 AC Line
Pin 2 AC Neutral
J2, J3, J4
Pin 1 -12V
Pin 2 +12V
Pin 3 Return
Pin 4 +5.1V
E1
Pin 1 Ground
Embedded Power for
Business-Critical Continuity
Rev.02.16.07
NFS50_7608J
4 of 4
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.