I Timers I 02 I www.crouzet-control.com
Output specication
Maximum breaking current 8 AAC 250 VAC resistive
8 ADC 30 VDC resistive
Minimum breaking current 10 mA / 5 VDC
Voltage breaking capacity 250 VAC / 8 AAC resistive
250 VDC / 0,3 A resistive
Electrical life (operations) 10⁵
8 A 250 VAC resistive
Mechanical life (operations) 10 x 10⁶
Breakdown voltage acc. to IEC/EN 61812-1 2,5 kV / 1 min / 1 mA / 50 Hz
Impulse voltage acc. to IEC/EN 60664-1, IEC/EN 61812-1 5 kV
wave 1.2 / 50 μs
1 or 2 changeover relays, AgNi (cadmium-free) 1 C/O
General characteristics
Conformity to standards IEC/EN 61812-1
IEC/EN 61000-6-1
IEC/EN 61000-6-2
IEC/EN 61000-6-3
IEC/EN 61000-6-4
Certications CE, UL, cUL, CSA, GL
Temperature limits use (°C) -20 →+60
Temperature limits stored (°C) -30 →+60
Installation category (acc. to IEC/EN 60664-1) Voltage surge category III
Creepage distance and clearance acc. to IEC/EN 60664-1 4 kV / 3 mm
Protection (IEC/EN 60529) IP20
IP40
Degree of protection acc. to IEC/EN 60529 Front face IP50
Vibration resistance acc. to IEC/EN 60068-2-6 20 m/s² 10 Hz →150 Hz
Relative humidity no condensation acc. to IEC/EN 60068-2-30 93 % non-condensing
Electromagnetic compatibility - Immunity to electrostatic discharges
acc to IEC/EN 61000-4-2
Level III (Air 8 kV / Contact 6 kV)
Immunity to radiated, radio-frequency, electromagnetic eld acc. IEC/
EN 61000-4-3
Level I (1 V/m : 2,0 G Hz →2,7 G Hz)
Level II (3 V/m : 1,4 G Hz →2,0 G Hz)
Level III (10 V/m : 80 M Hz →1 G Hz)
Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4 Level III (direct 2 kV / Capacitive coupling clamp 1 kV)
Immunity to shock waves on power supply acc. to IEC/EN 61000-4-5 Level III (2 kV / common mode 2 kV/residual current mode 1 kV)
Immunity to radio frequency in common mode acc. to
IEC/EN 61000-4-6
Level III (10V rms : 0.15 M Hz to 80 M Hz)
Immunity to voltage dips and breaks acc. to IEC/EN 61000-4-11 0 % residual voltage, 1 cycle
70 % residual voltage, 25/30 cycles
Mains-borne and radiated emissions acc. to EN 55022 (CISPR22),
EN55011 (CISPR11)
Class B
Fixing : Symmetrical DIN rail 35 mm
Terminal capacity Single-wire without ferrule 1 x 0,5 →3,3 mm² (AWG 20 →AWG 12)
2 x 0,5 →2,5 mm² (AWG 20 →AWG 14)
Terminal capacity Multi-wire with ferrule 1 x 0,5 →2,5 mm² (AWG 20 →AWG 14)
2 x 0,5 →1,5 mm² (AWG 20 →AWG 16)
Housing material Self-extinguishing
Shock test IEC/EN 60068-2-27 15 g - 11 ms
Short interruption on power line acc to IEC/EN 61000-4-11 0 % residual voltage, 250/300 cycles
Spring terminals, 2 terminals per connection point - exible wire 2 x 0,5 →1,5 mm² (AWG 20 →AWG 16)
Spring terminals, 2 terminals per connection point - rigid wire 2 x 0,5 →1,5 mm² (AWG 20 →AWG 16)