™ Scotch-Weld™
Urethane Adhesive
DP608 Black
the adhesive bond line was approximately 0.005". All strengths were
measured at 73°F (23°C) except when noted.
The separation rate of the testing jaws was 0.1 in. per minute for metals, 2 in.
per minute for plastics and 20 in. per minute for rubbers. The thickness of the
substrates were: steel, 0.060 in.; other metals, 0.05-0.064 in.; rubbers,
0.125in.; plastics, 0.125 in. and samples were allowed to cure at 75°F (24°C)
and approximately 50% RH for 1 week before tested. The separation rate of the
testing jaws was 0.1 inch per minute for metals and 2 inches per minute for
plastics.
B. Floating Roller Peel (Bell Peel) (ASTM D3167)
Bell peel strengths were measured on 1 in. wide bonds at the temperatures
noted. The testing jaw separation rate was 6 in. per minute. The bonds were
made with 0.064 in. bonded to 0.025 in. thick adherends.
C. Cure Cycle
All bonds were cured 7 days at 73°F (23°C) at 50% RH before testing or
subjected to further conditioning or environmental aging.
3M™ Scotch-Weld™ Urethane Adhesive DP608 is supplied in dual syringe plastic
duo- pak cartridges as part of the 3M™ EPX™ Applicator System. The duo-pak
cartridges are supplied in 50 ml configuration. To use the EPX cartridge system
simply insert the duo-pak cartridge into the EPX applicator. Next, remove the duo-
pak cartridge cap and expel a small amount of adhesive to be sure both sides of the
duo-pak cartridge are flowing evenly and freely. If simultaneous mixing of Part A
and Part B is desired, attach the EPX mixing nozzle to the duo-pak cartridge and
begin dispensing the adhesive.
When mixing Part A and Part B manually the components must be mixed in the
ratio indicated in the typical uncured properties section of this data sheet.
Complete mixing of the two components is required to obtain optimum properties.
Two-part mixing/proportioning/dispensing equipment is available for intermittent
or production line use. These systems are ideal for line uses because of their
variable shot size and flow rate characteristics and are adaptable to most
applications.
Apply adhesive to clean, dry surfaces, joint parts and secure until adhesive sets.
The following surface preparations were used for substrates described in this
Technical Data Sheet.
A. Aluminum Etch
Optimized FPL Etch - 3M (test method C-2803)
1. Alkaline degrease – Oakite 164 solution (9-11 oz./gallon water) at 190°F ± 10°F
(88°C ± 5°C) for 10-20 minutes. Rinse immediately in large quantities of cold
Handling and
Application
Information
Directions for Use