SCP1000 Series
VTI Technologies Oy Subject to changes 1/6
www.vti.fi
SCP1000 SERIES (120 kPa) ABSOLUTE PRESSURE SENSOR
Features
30 kPa - 120 kPa measurin g range
Single +2.4 … 3.3 V supply
Four measuring modes plu s power
down mode
On-chip temperature meas urement
Fully calibrated and comp ensated
component
Standard digital output: SPI or I2C (1
Small package size with optional (2 sealing
gasket. Diameter 6.1 mm, height 1.7 mm
Proof pressure 2.0 MPa
Pb-free solderable component & RoHS-
compatible
Applications
Barometric pressure measurement and
altimeter applications
Home weather stations
Advanced medical applications
Level gauging
Benefits
1.5 Pa ( 10cm at sea level) resolution with
< 10 µA current consumption
Altimeter/barometer function can be
realized with minimum use of MCU
Chemically and mechanically robust
package
Ordering Information
Product Description
SCP1000-D01 30 kPa - 120 kPa, SPI interface
SCP1000-D11 30 kPa - 120 kPa, I2C interface
Absolute Maximum Ratings
Parameter
Value Unit
Supply voltage (Vdd) -0.3 to +3.6 V
Voltage at input / output pins (3 -0.3 to (Vdd + 0.3) V
ESD (Human Body Model) ±2.0 kV
ESD (Charged Device Mode) ±0.5 kV
Storage temperature -30 ... +85 °C
Proof pressure 2.0 MPa
Note 1) I2C compatible TWI (Two Wire Interface)
Note 2) VTI's I-seal gasket
Note 3) Referred to DVDD
Data Sheet
SCP1000 Series
VTI Technologies Oy Subject to changes 2/7
www.vti.fi
Electrical Characteristics
Vdd = 2.7 V and ambient temperature unless otherwise specified
Parameter Condition Min. Typ Max. Units
Supply voltage Vdd 2.4 3.3 V
High resolution mode 25 µA
High speed mode 25 µA
Ultra low power mode 3.5 µA
Current Consumption
Power down 200 500 nA
Output Load @ 500 kHz 50 pF
Digital Pins Input Capacitance 1.6 pF
SPI Clock Frequency 500 kHz
I2C Clock Frequency 400 kHz
Data Transfer Time @ 500 kHz 120 µs
Performance Characteristics(4
Parameter Condition Min. Typ Max. Units
Operating Pressure Range Nominal 30 120 kPa
Operating Temperature -20 +70 °C
Resolution (5 High resolution mode 1.5 3 Pa
High speed mode 3 6 Pa
Relative Pressure Accuracy (5 600 hPa...1200 hPa
+10 °C ... +40 °C -50 +50 Pa
Absolute Pressure Accuracy (5 600 hPa...1200 hPa
+10 °C ... +40 °C -150 +150 Pa
Absolute Pressure Accuracy (5 300 hPa...1200 hPa
-20 °C ... +70 °C -200 +400 Pa
Long-term Stability 12 months +100 Pa
Digital pressure output data
word length 19 bits
Digital temperature output data
word length 14 bits
Pressure Data Output Refresh
Rate High resolution mode 1.8 Hz
High speed mode 9 Hz
Temp. Resolution 0.2 0.5 °C
Temp. Accuracy -2 ±1 +2 °C
Note 4 Soldered components. Detailed information about the effect of soldering and mounting can be found in SCP1000 Pressure
Sensor Assembly Instructions (Technical Note 51)
Note 5 Typical = Median, Min. /Max. = 95% of the components within the population
SCP1000 Series
VTI Technologies Oy Subject to changes 3/7
www.vti.fi
Interface Options
Communication interface is pre-programmed in the factory and it can be either SPI (Serial Peripheral
Interface) or I2C (Inter-Integrated Circuit). The SPI interface is a full duplex 4 wire interface and the
connection between the MCU and SCP1000 is achieved using MOSI, MISO, SCK and CSB. The I2C
interface is slave-only half duplex two-wire interfa ce a v ailable on SDA and SCL pins.
Interface Options
The SCP1000 Pressure sensor has 4 normal operation modes plus power down mode.
Mode Pressure measurement Resolution Output data refresh rate
High resolution Continues 17 bits 1.8 Hz
High speed Continues 15 bits 9 Hz
Ultra low power Periodical 15 bits Approximately 1 Hz
Low power External trigger 17 bits or 15 bits
Power Down Activated thro ugh PD pin
Electrical Connections
The SCP1000 pressure sensor supports two communication interfaces, SPI and I2C. Appropri ate
communication interfa ce i s pre -programmed in the factory.
SCP1000- D01 (SPI Interface)
Pin # Name Function Characteristics
1 ATST Connect to analog ground For factory use only
2 TRIG(6 Trigger input, connect to GND if
not used Digital input
3 DRDY Interrupt signal (data ready) Digital output
4 CLK Connect to digital GND
5 DVDD Digital supply voltage Powe r line
6 DVSS Digital ground Power line
7 DVDDS Digital supply filter Digital power supply filter
8 PD(6 Power down, connect to GND if
not used Input to force the chip in power down
mode
9 SCK(6 SPI clock input Interface clo ck
10 MOSI(6 SPI data input Digital data input
11 MISO(6 SPI data output Digital data output
12 CSB(6 SPI chip select Digital input
13 AVDD Analog supply voltage Power line
14 AVSS Analog ground Power line
15 AVSS Analog ground Power line
16 ATST Connect to analog g rou nd For factory use only
Note 6 The MCU has to actively drive the signal in high and low states
SCP1000 Series
VTI Technologies Oy Subject to changes 4/7
www.vti.fi
SCP1000- D11 (I2C Interface)
Pin # Name Function Characteristics
1 ATST Connect to analog ground For factory use only
2 TRIG(6 Trigger input, connect to GND if
not used Digital input
3 DRDY Interrupt signal (data ready) Digital output
4 CLK Connect to digital GND
5 DVDD Digital supply voltage Powe r line
6 DVSS Digital ground Power line
7 DVDDS Digital supply filter Digital power supply filter
8 PD(6 Power down, connect to GND if
not used Input to force the chip in power down
mode
9 SCL(6 I
2C serial clock Interface clock
10 SDA(6 I2C data I2C data input/output
11 MISO n/c n/c
12 CSB Connect to analog supply
voltage
13 AVDD Analog supply voltage Power line
14 AVSS Analog ground Power line
15 AVSS Analog ground Power line
16 ATST Connect to analog g rou nd For factory use only
Note 6 The MCU has to actively drive the signal in high and low states
Figure 1 Pin arrangement of SCP1000
Note: In order to ensure the contact reliability, both pins in the pin pairs 1,16 and 14,15 (which are internally
connected together) should be sol dered.
Pressure element location
SCP1000 Series
VTI Technologies Oy Subject to changes 5/7
www.vti.fi
PWB Pad Layout
Dimensions
SCP1000 Series
VTI Technologies Oy Subject to changes 6/7
www.vti.fi
Typical Performance characteristics
SCP1000 Series
VTI Technologies Oy Subject to changes 7/7
www.vti.fi
Resolution distribution in high re solution measurement mode [Pa], N=534
Number of samples
Resolution
[
Pa
]