100 Watt Single Output Half Brick DC/DC Converter
VKA100xS
18-36V and 33 - 75V Input Range
High Efficiency: 87% Typical at
5V
100µS Transient Response 50-
100% Load Step
420 kHz Fixed-Frequency
Operation
Remote Sense
Operation to +100°C Baseplate
Temperature
Primary Remote On/Off, Choice of
Pos/Neg Logic
Adjustable Output Voltage
Continuout Short-Circuit Protection
Thermal Shutdown
Case Ground Pin
Corporate: www.cdtechno.com
Product: www.cdpowerelectronics.com
The VKA100xS Series DC/DC
converters present an economical
and practical solution for distrib-
uted power system architectures
which require high power density
and efficiency while maintaining
system modularity and
upgradeability. With the ability to
operate over a wide input voltage
range of 18 to 36 and 33 to 75
volts, these modules are ideal for
use in battery backup applications
common in todays' telecommuni-
cation and electronic data process-
ing applications. The output is
fully isolated from the input,
allowing for a variety of polarity
and grounding configurations.
The VKA100xS's proprietary
control circuitry responds to 50-
100% load steps in 100µSeconds
to within 1% nominal Vout.
The patented fixed frequency
architecture combined with sur-
face mount technology results in a
compact, efficient and reliable
solution to DC/DC conversion
requirements. Safety Per UL1950,
EN 60950 and CSA 22.2 #234
MODEL INPUT VOUT IOUT EFFICIENCY
VOLTAGE (VDC) (A) MIN TYP
VKA100LS02 2.0V 20.0 75 76
VKA100LS02F 2.0V 30.0 73 74
VKA100LS2V5F 2.5V 30.0 75 76
VKA100LS03 3.3V 20.0 80 81
VKA100LS03F 3.3V 30.0 80 81
VKA100LS05 24VDC 5.0V 20.0 85 86
VKA100LS12 12.0V 8.3 87 88
VKA100LS15 (18-36) 15.0V 6.7 88 89
VKA100LS24 24.0V 4.2 89 90
VKA100MS02 2.0V 20.0 76 77
VKA100MS02F 2.0V 30.0 74 75
VKA100MS2V5F 2.5V 30.0 77 78
VKA100MS03 3.3V 20.0 81 82
VKA100MS03F 3.3V 30.0 81 82
VKA100MS05 48VDC 5.0V 20.0 86 87
VKA100MS12 12.0V 8.3 88 89
VKA100MS15 (33-75) 15.0V 6.7 89 90
VKA100MS24 24.0V 4.2 89 90
PRODUCT SELECTION CHART
2
VKA100xs Rev C 3/2001
Product: www.cdpowerelectronics.com
SPECIFICATIONS, ALL MODELS
Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified.
INPUT
PARAMETER CONDITIONS MIN TYP MAX UNITS
INPUT
Voltage Range
VKA100LS 18 24 36 VDC
VKA100MS 33 48 75 VDC
Maximum Input Current
VKA100LS VIN = 16VDC 7.4 A
VKA100MS VIN = 27VDC 4.4 A
Reflected Ripple Current Peak - Peak 20 mA
Input Ripple Rejection DC to 1KHz 50 60 dB
No Load Input Current LS/MS 50/100 mA
Power Dissipation LS/MS
No Load 3.6/4.8 W
Standby, Primary On/Off
Disabled LS/MS 0.18/0.4 W
Inrush Charge VIN = VINmax.
VKA100LS 0.520 mC
VKA100MS 0.360 mC
Quiescent Operating Current
Primary On/Off Disabled 8 12 mA
OUTPUT
PARAMETER CONDITIONS MIN TYP MAX UNITS
Rated Power 0 100 W
Set point Accuracy 1%
Line Regulation High Line to Low Line 0.02 0.05 %
Load Regulation No Load to Rated Load 0.02 0.05 %
Output Temperature Drift ±.02 %/°C
Output Ripple, p-p DC to 20MHz BW 1% VOUT, Nom
Output Current Limit Inception 130% lOUT, Nom
Output Short-Circuit Current (2) test 110% lOUT, Nom
Output Overvoltage Limit 125% 135% V
Transient Response 50 to 100% Load Step
Peak Deviation di/dt = 0.1A/µSec 2% VOUT, Nom
Settling Time VOUT, 1% of Nominal Output 100 µSec
GENERAL
PARAMETER CONDITIONS MIN TYP MAX UNITS
ISOLATION
Input to Output Peak Test for 2 Seconds 1500 VDC
Input to Baseplate 1500 VDC
Output to Baseplate 500 VDC
Resistance 10 M
Capacitance 2000 pF
Leakage Current VISO = 240VAC, 60Hz 180 µA, rms
GENERAL
Efficiency, Line, Load, Temp. (3)
Switching Frequency 400 420 440 KHz
Remote Sense Compensation 0.5 V
Output Voltage Adjust Range 12 V & higher(4) -50% / +25% VOUT, Nom
Remote On/Off Control Inputs
Primary Open Collector/Drain
Sink Current-Logic Low 1.0 mA
Vlow 0.4 V
Vhigh0 Open Collector
Turn-on Time Within 1% of Rated Output 10.0 12.5 mSec
Weight 85 (3.0) g (oz.)
TEMPERATURE
Operation/Specification Case Temperature -40 +25 +100 °C
Storage Case Temperature -55 +25 +125 °C
Shutdown Temperature Case Temperature +100 +115 °C
Thermal Impedance, case-ambient 7.1 °C/W
Lead Solder Temperature 10 Seconds max +300 °C
NOTES: (1) See Typical Performance Curves, page 3
(2) Continuous Mode
(3) See graphs for Efficiency vs. Output Load, VIN, TCASE
(4) 3.3V Models Limited in Trim Down Range
(5) Consult Factory for Details
3
Product: www.cdpowerelectronics.com VKA100xs Rev C 3/2001
TYPICAL PERFORMANCE CURVES
TCASE = +40°C nominal input voltage unless otherwise specified.
VKA100 xSzz -
Device Family
Indicates 100 Watt Regulated Unit
Model Number
Selected from Table of Electrical Characteristics
Where:
x = Input Voltage (L = 24VDC; M = 48VDC)
zz = Output Voltage (03=3.3V, 05=5V, etc.)
Lead Length
0.200" - No Number
0.145" - (6)
0.110" - (8)
Remote On-Off Logic:
Positive - No Number
Negative - (1)
ORDERING
INFORMATION
4
VKA100xs Rev C 3/2001
Product: www.cdpowerelectronics.com
1.000
[25.40]
1.400
[35.56]
2.000
[50.80]
0.19 [4.8]
0.20 [5.1]
0.50 [12.7]
0.40 [10.16]
0.530 MAX
[13.46]
0.20 [5.1] .040 [1.02] DIA.
7 PLACES
.081 [2.06] DIA.
2 PLACES
1.400
[35.56]
1.000
[25.40]
0.700
[17.78]
.400 [10.16]
1.900
[48.26]
2.28
[57.91]
MAX
MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES
MAX. TORQUE, 8 IN/LBS
2.40
[61.0]
MAX
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.770.9369
C&D Technologies (Power Electronics) Ltd.
Shannon, Co. Clare, Ireland
Tel: +353.61.474.133 Fax:+353.61.474.141
C&D Technologies, (NCL)
Milton Keynes MK14 5BU UK
Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545
MECHANICAL
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be
accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or
completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby
disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from
any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in
user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.
Special attention should be given to the peak voltage
deviation during a dynamic load step when trimming
the output above the original set point to avoid
tripping the overvoltage protection circuit. Should an
OVP condition occur, the converter will go into a
latch condition and must be externally reset before it
will return to normal operation.
This feature allows the user to accurately adjust the
module's output voltage set point to a specified level.
This is achieved by connecting a resistor or potentiometer
from the TRIM terminal to either the +Vout terminal (for
increased Vout) or the -Vout terminal (for decreased
Vout). The formulae below describe the trim resistor
value to obtain a Vout change of %. VO is output
voltage prior to adjustment (3.3V, 5V, 12V, 15V, or 24V).
Radj - up = ( Vo(100 + %) _ (100 + 2%) ) k
1.225% %
Radj - down = (100 - 2) k
%
NOTES:
All dimensions are in inches (millimeters).
PIN PLACEMENT TOLERANCE: ± 0.005"
MECHANICAL TOLERANCE: ± 0.015"
Marked with: specific modeL ordered, date code, job code.
MATERIAL: Units are encapsulated in a low thermal
resistance molding compound which has excellent chemical
resistance and electrical properties in high humidity
environments and over a wide operating temperature range.
The encapsulant and outer shell of the unit have UL94V-0
ratings. Lead material is solder plated to allow ease of
solderability.
OUTPUT ADJUST VOLTAGE OVP NOTE