Discontinued JV JV RELAYS FLAT TYPE POWER RELAY 22 .866 FEATURES 16 .630 * Flat type: 16 mm (length) x 22 mm (width) x 10.9 mm (height) (.630x.866x.429 inch) * High capacity type (16A) available * High sensitivity type (100 mW: 1 Form A) available * TUV also approved 10.9 .429 mm inch SPECIFICATIONS Contact High capacity High type sensitivity type Standard type Arrangement 1 Form A 1 Form C Initial contact resistance, max. (By voltage drop 6 V DC 1 A) 1 Form A 50 m Contact material Silver alloy Nominal switching capacity 10 A 125 V AC Max. switching power Rating (resistive) Max. switching voltage 10 A 125 V AC (N.O.) 16 A 125 V AC 10 A 125 V AC 6 A 125 V AC (N.C.) 1,250 VA 1,250 VA (N.O.) 750 VA (N.C.) 10 A 10 A (N.O.) 6 A (N.C.) 2,000 VA 1,250 V Expected life (min. ope.) Mechanical at (180 cpm) 16 A Flux-resistant type 105 105 3x104 5x104 3x105 105 105 105 Standard type Initial breakdown voltage*2 Between open contacts 1,000 Vrms for 1 min. Between contacts and coil 1,500 Vrms for 1 min. Approx. 10 ms Approx. 5 ms (100 V DC coil type) Functional*4 Shock resistance Destructive*5 400 mW (up to 48 V coil type) 600 mW (100 V coil type) 100 mW -- * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage"section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms, detection time: 10s *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10s *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (see catalog). *8 100V type: -40 to + 60C -40 to + 140F Min. 98 m/s2 {10 G} Min. 980 m/s2 {100 G} Functional*6 10 to 55 Hz at double amplitude of 1.0 mm Destructive 10 to 55 Hz at double amplitude of 1.6 mm Vibration resistance -- Approx. 4 ms Max. 65C with nominal coil voltage across coil and at nominal switching capacity 1 Form C type 200 mW (up to 48 V coil type) 600 mW (100 V coil type) Nominal operating High capacity type power High sensitivity type Remarks Min. 100 M (at 500 V DC) Temperature rise (at 50C) Coil 1 Form A type 20 cpm Initial insulation resistance*1 Release time (without diode)*3 (at nominal voltage) 10 A 107 Sealed type Max. operating speed Operate time*3 (at nominal voltage) 125 V AC Max. switching current Electrical at resistive (at 20 cpm) (at rated load) 1 Form A Characteristics Conditions for opera- Ambient -40C to +70C*8 -40F to +158F tion, transport and temp. storage*7 (Not freezing and 5 to 85%R.H. condensing at low Humidity temperature) Unit weight Approx. 8 g .282 oz TYPICAL APPLICATIONS 1. Home appliances: Air conditioners, heaters, etc. 2. Automotive: Power supply for car stereo and air conditioner ORDERING INFORMATION Ex. JV 1a P F Contact arrangement Rating Protective construction 1: 1 Form C 1a: 1 Form A Nil: Standard type P: High capacity type* Nil: Sealed type F: Flux-resistant type S Sensitivity Nil: Standard type (1 Form A: 200 mW, 1Form C: 400 mW 100 V DC coil type: 600 mW) S: High sensitivity type* (1 Form A: 100 mW) Notes: 1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs. 2. Coil voltage DC 48, 100 V types are not available for high sensitivity type. UL/CSA, TUV approved type is standard. en_ds_61139_0001: 010705D 12V Coil voltage (DC) 5, 6, 9, 12, 18, 24, 48, 100V * Only for 1 Form A type 1 JV TYPES Contact arrangement Part No. Coil voltage, V DC 1 Form A Standard type 1 Form A High capacity type 1 Form A High sensitivity type 1 Form C Sealed type Flux-resistant type 5 JV1a-5V JV1aF-5V 6 JV1a-6V JV1aF-6V 9 JV1a-9V JV1aF-9V 12 JV1a-12V JV1aF-12V 18 JV1a-18V JV1aF-18V 24 JV1a-24V JV1aF-24V 48 JV1a-48V JV1aF-48V 100 JV1a-100V JV1aF-100V 5 JV1aP-5V JV1aPF-5V 6 JV1aP-6V JV1aPF-6V 9 JV1aP-9V JV1aPF-9V 12 JV1aP-12V JV1aPF-12V 18 JV1aP-18V JV1aPF-18V 24 JV1aP-24V JV1aPF-24V 48 JV1aP-48V JV1aPF-48V 100 JV1aP-100V JV1aPF-100V 5 JV1aS-5V JV1aFS-5V 6 JV1aS-6V JV1aFS-6V 9 JV1aS-9V JV1aFS-9V 12 JV1aS-12V JV1aFS-12V 18 JV1aS-18V JV1aFS-18V 24 JV1aS-24V JV1aFS-24V 5 JV1-5V JV1F-5V 6 JV1-6V JV1F-6V 9 JV1-9V JV1F-9V 12 JV1-12V JV1F-12V 18 JV1-18V JV1F-18V 24 JV1-24V JV1F-24V 48 JV1-48V JV1F-48V 100 JV1-100V JV1F-100V COIL DATA (at 20C 68F) Part No. 1 Form A (Standard type & High capacity type) Nominal voltage, Pick-up voltage, V DC V DC (max.) 1 Form C Nominal operatNominal ing current, mA operating power, (10%) mW Max. allowable voltage, V DC 4.0 0.25 125 40 200 6 4.8 0.3 180 33.3 200 9 9 7.2 0.45 405 22.2 200 13.5 7.5 12 9.6 0.6 720 16.7 200 18 18 14.4 0.9 1,620 11.1 200 27 24 19.2 1.2 2,880 8.3 200 36 48 38.4 2.4 11,520 4.2 200 72 48 3 110 16,600 6 600 5 4.0 0.25 250 20 100 9 6 4.8 0.3 360 16.7 100 10.8 9 7.2 0.45 810 11.1 100 16.2 12 9.6 0.6 1,440 8.3 100 21.6 18 14.4 0.9 3,240 5.6 100 32.4 24 19.2 1.2 5,760 4.2 100 43.2 5 4.0 0.25 62.5 80 400 6.5 6 4.8 0.3 90 66.7 400 7.8 9 7.2 0.45 202.5 44.4 400 11.7 12 9.6 0.6 360 33.3 400 15.6 18 14.4 0.9 810 22.2 400 23.4 24 19.2 1.2 1,440 16.7 400 31.2 48 38.4 2.4 5,760 8.3 400 70 5 6 600 100 2 Coil resistance, (10%) 5 100 1 Form A (High sensitivity type) Drop-out voltage, V DC (min.) 16,600 62.4 110 en_ds_61139_0001: 010705D JV DIMENSIONS mm inch 1 Form A type 1 Form C type 22 .866 16 .630 22 .866 16 .630 10.5 0.4 .413 .016 10.5 0.4 .413 .016 4 .157 4 .157 17.78 .700 2 17.78 .700 1 COM 3 17.78 .700 PC board pattern (Copper-side view) NO 2-1.3 dia. 2-.051 dia. Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .197 inch Min. 5mm .197 inch General tolerance 0.2 .008 0.3 .012 0.4 .016 NO NC 5 4 10.16 .400 10.16 .400 17.78 .700 1 COM 3 12.7 .500 10.16 .400 PC board pattern (Copper-side view) 2 12.7 .500 NC 5 4 2-0.9 dia. 2-.035 dia. 12.7 .500 12.7 .500 7.62 .300 3-1.3 dia. 3-.051 dia. Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .197 inch Min. 5mm .197 inch Tolerance: 0.1 .004 2-0.9 dia. 2-.035 dia. 10.16 .400 General tolerance 0.2 .008 0.3 .012 0.4 .016 7.62 .300 Tolerance: 0.1 .004 REFERENCE DATA 1.-(1) Maximum value for switching capacity (1 Form A type) 1.-(2) Maximum value for switching capacity (1 Form C type) 100 16 10 Contact current, A High capacity type, AC resistive load Standard type, AC resistive load AC resistive load (NO side) 10 1 1 18 Operate/release time, ms 100 Contact current, A 2.-(1) Operate/release time (Standard 1 Form A type) 16 14 12 Operate time 10 8 6 4 Max. - x Min. Max. - x Min. Release time 2 100 10 1,000 16 14 12 10 Operate time 6 Release time 2 0 80 100 120 80 100 120 140 160 180 Coil applied voltage, %V 140 160 Max. - x Min. Max. - x Min. 180 10 8 Operate time 6 Max. - x Min. Max. - x Min. 4 Release time 2 0 80 100 Coil applied voltage, %V 3.-(1) Coil temperature rise (1 Form A type) 120 140 15 A at 26C 79F (High capacity type) 80 3.-(3) Coil temperature rise (High sensitivity type) Measured portion: Inside the coil Measured portion: Inside the coil 10 A at 15C 59F (Standad type) 15 A at 60C 140F (High capacity type) 60 10 A at 60C 140F (Standad type) 40 20 160 0 80 100 Coil applied voltage, %V 3.-(2) Coil temperature rise (1 Form C type) 120 140 160 180 Coil applied voltage, %V 4. Life curve Operation frequency: 20 times/min. (ON/OFF = 1.5s:1.5s) Ambient temperature: Room temperature 60 100 Standard 200 mW type 10 A at 25C 77F 60 40 125V AC resistive load 40 High sensitivity 100 mW type Life, x104 80 Temperature rise, C Temperature rise, C 0 Measured portion: Inside the coil 18 4 1,000 2.-(3) Operate/release time (1 Form C type) Operate/release time, ms Operate/release time, ms 2.-(2) Operate/release time (High capacity 1 Form A type) 8 100 Contact voltage, V Contact voltage, V Temperature rise, C 10 10 20 20 0 80 100 120 140 160 180 Coil applied voltage, %V en_ds_61139_0001: 010705D 0 0 100 120 140 160 180 200 Coil applied voltage, %V 1 4 6 8 10 12 14 16 18 Contact current, A 3 JV 5.-(3) Ambient temperature characteristics (1 Form C type) Contact current: 10 A Contact current: 0 A, 10 A, 13 A, 15 A Contact current: 10 A Allowable ambient temperatures against % coil voltage (max. inside the coil temperature set as 115C 239F) 300 200 Pick-up voltage with a hot-start condition of 100%V on the coil 100 0 10 200 13 A 15 A 100 Pick-up voltage 0 20 40 60 80 100 A 300 120 0 Coil applied voltage, %V Coil applied voltage, %V 5.-(2) Ambient temperature characteristics (High capacity 15 A type, 1 Form A) Coil applied voltage, %V 5.-(1) Ambient temperature characteristics (Standard 10 A type, 1 Form A) A Allowable ambient temperature against % coil voltages (max. inside the coil temperature set as 15 A 13 A 115C 239F) Pick-up voltage with a hot-start condition of 100%V on the coil 10 A Pick-up voltage 0A 20 40 60 80 100 120 200 Pick-up voltage 100 0 Ambient temperature, C Ambient temperature, C Allowable ambient temperatures against % coil voltages (max. inside the coil temperature set as 115C 239F) 20 40 60 80 Ambient temperature, C 5.-(4) Ambient temperature characteristics (High sensitivity type) Contact current: 10 A Coil applied voltage, %V 300 High sensitivity 100 mW type Standard 200 mW type 200 Allowable ambient temperature against % coil voltages (max. inside the coil temperature set as 115C 239F) 100 0 0 20 40 60 80 100 120 Temperature rise, C Types dedicated to a wider variety of automotive applications are available, upon receipt of order, with the following specifications: SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material Nominal switching capacity Rating (resistive Max. switching power load) Max. switching voltage Max. switching current Mechanical (at 300 cpm) Expected life (min. Electrical (DC 12 V motor, 6 A steady current, ope.) 20 A lock current)(at rated load) 1 Form C 100 m Nominal operating power Min. 100 M (at 500 V DC) Initial break Between open contacts down voltage Between contacts and coil 1,500 Vrms for 1 min. 10 A 125 V AC 6A 30 V DC Operate time (at nominal voltage) Approx. 5 ms 1,250 V AC 180 W 125 V (AC) 30 V (DC) 10 A (AC) 6 A (DC) Release time (at nominal voltage) Temperature rise (max.) (at nominal voltage)(at 50C) Shock resistance 5x106 4x104 5, 6, 9, 12, 18, 24 450 mW Pick-up voltage, V DC (max.) 70% of nominal voltage Drop-out voltage; V DC (min.) 5% of nominal voltage Max. allowable voltage 20 cpm Initial insulation resistance Silver alloy Coil Nominal voltage, V DC Max. operating speed Approx. 4 ms 65C with nominal coil voltage and at maximum allowable contact current Functional Min. 196 m/s2 {20 G} Destructive Min. 980 m/s2 {100 G} Functional 10 to 55 Hz at double amplitude of 1.6 mm Destructive 10 to 55 Hz at double amplitude of 2 mm Vibration resistance Conditions for operation, Ambient transport and storage temp. (Not freezing and condensHumidity ing at low temperature) Unit weight 750 Vrms for 1 min. -40C to +70C -40F to +158F 5 to 85%R.H. Approx. 8 g .282 oz 150% of nominal voltage For Cautions for Use, see Relay Technical Information (see catalog). 4 en_ds_61139_0001: 010705D