cui.com
date 06/21/2018 │ page 3 of 10CUI Inc │ SERIES: PDQE10 │ DESCRIPTION: DC-DC CONVERTER
OUTPUT (CONTINUED)
parameter conditions/description min typ max units
cross regulation
dual output models:
main output 50% load
secondary output from 10~100% load
±5 %
switching frequency11 PWM mode 350 kHz
transient recovery time 25% load step change, nominal input voltage 300 500 μs
transient response deviation 25% load step change, nominal input voltage ±3 ±5 %
temperature coecient at full load ±0.03 %/°C
Note: 11. Value is based on full load. At loads <10%, the switching frequency decreases with decreasing load
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection 110 160 %
over current protection 110 140 190 %
short circuit protection continuous, self recovery
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output for 1 minute at 1 mA 1,500 Vdc
isolation resistance input to output at 500 Vdc 1,000 MΩ
isolation capacitance input to output, 100 kHz / 0.1 V 1,000 pF
safety approvals12 UL 60950-1
conducted emissions CISPR22/EN55022, class A (no external circuit); class B (external circuit required, see Figure 3-b)
radiated emissions CISPR22/EN55022, class A (no external circuit); class B (external circuit required, see Figure 3-b)
ESD IEC/EN61000-4-2, contact ± 4kV, class B
radiated immunity IEC/EN61000-4-3, 10V/m, class A
EFT/burst IEC/EN61000-4-4, ± 2kV, class B (external circuit required, see Figure 3-a)
surge IEC/EN61000-4-5, line-line ± 2kV, class B (external circuit required, see Figure 3-a)
conducted immunity IEC/EN61000-4-6, 3 Vr.m.s, class A
voltage dips & interruptions IEC/EN61000-4-29, 0%-70%, class B
MTBF as per MIL-HDBK-217F, 25°C 1,000,000 hours
RoHS yes
Note: 12. See specic chassis mount and DIN-rail mount versions with UL approval on page 1.