建 準 電 機
SUNONWEALTH
Page 4 of 14
3. PERFORMANCE CHARACTERISTIC
RATED SPEED 2900 RPM ± 10% at rated voltage
AIR FLOW 37 CFM
STATIC PRESSURE 0.15 Inch-H2O
ACOUSTIC NOISE 30 dB(A)
AIR FLOW V.S. PRESSURE See Page 5
INSULATION CLASS UL Class A
INSULATION RESISTANCE
PLASTIC HOUSING 10M ohm at 500 VDC between internal stator and
lead wire (+)
DIELECTRIC STRENGTH Applied AC 500 V for one minute or AC 600 V for 2
Seconds between housing and lead wire (+)
LIFE EXPECTANCY 60,000 Hours at 40 deg. C, 65% humidity, 90% CL
;Automatic Restart
Note: In a situation where the fan is locked by an external
force while the electricity is on, an increase in coil
temperature will be prevented by temporarily turning off the
electrical power to the motor. The fan will automatically
restart when the locked rotor cond ition is released.
PROTECTION
Polarity Protection
4. SAFETY
SAFETY UL CUR TUV
NO. 3 3 3