V23826-K15-Cxx, V23826-K15-Cxxx Product Specification – August 2004
© Finisar Corporation August 27, 2004 Rev. B Page 10
Receiver Electro-Optical Characteristics
Parameter Symbol Values Unit
min. typ. max.
Sensitivity (Average Power)1) PIN –22 –20 dBm
Saturation (Average Power) PSAT –3 dBm
Signal Detect Assert Level2) PSDA –20 dBm
Signal Detect Deassert Level3) PSDD –30 dBm
Signal Detect Hysteresis PSDA
–PSDD
1.5 dB
Signal Detect Assert Time tASS 100 µs
Signal Detect Deassert Time tDAS 350 µs
Output Low Voltage4) VOL–VCC –1950 –1600 mV
Output High Voltage4) VOH–VCC –1025 –720 mV
Signal Detect Output Low
Voltage AC/AC TTL5) VSDL 0.5 V
Signal Detect Output High
Voltage AC/AC TTL5) VSDH 2V
Data Output
Differential Voltage6) VDIFF 0.5 0.9 V
Output Data Rise/Fall Time,
20% - 80%
tR, tF375 ps
Return Loss of Receiver ORL 12 dB
Notes:
1) Minimum average optical power at which the BER is less than 1x10E–12 or lower. Measured with a 27–1 NRZ
PRBS and ER = 9 dB. Output of single mode fiber 9 µm diameter.
2) An increase in optical power above the specified level will cause the Signal Detect output to switch from a low
state to a high state.
3) A decrease in optical power below the specified level will cause the Signal Detect to change from a high state
to a low state.
4) DC/DC, AC/DC for data. DC/DC, AC/DC, AC/AC PECL for Signal Detect. PECL compatible. Load is 50 Ω into
VCC–2 V for data, 500 Ω to VEE for Signal Detect. Measured under DC conditions. For dynamic measurements
a tolerance of 50 mV should be added. VCC = 3.3 V/5 V. TAMB = 25°C.
5) Max. output current high: –0.4 mA (drive current), max. output current low: +2 mA (sink current).
6) AC/AC for data. Load 50 Ω to GND or 100 Ω differential. For dynamic measurement a tolerance of 50 mV
should be added.