www.saia-burgess.com
saia-burgess Switches 28 |29
F4
Operating Characteristics
Actuating Release Free Operating Movement Over
Actuator Reference Force Force Position Position Differential travel
Maximum Minimum Maximum Maximum
(N) (ozf) (N) (ozf) (mm) (in) (mm) (in) (mm) (in)
Plunger
F4T6 1,4 5,00 0,25 0,90 8,8 0,35 8,1 +0.3 0,32 +0.01 0,13 0,005 *
F4T7 –0.2 –0.008
Y1-Lever
F4T6Y1 0,6 2,20 0,07 0,25 10,0 0,39 8,2 +1.0 0,32 +0.04 0,70 0,030 *
F4T7Y1 –0.7 –0.03
Width of lever 3.0 mm/0.12 in
YC-Lever
F4T6YC 0,7 2,50 0,09 0,32 11,7 0,46 10,3 +0.8 0,41 +0.03 0,45 0,020 *
F4T7YC –0.55 –0.02
Width of lever 3.0 mm/0.12 in
Operating characteristics are specified from the mounting holes.
* Plunger can be depressed flush with housing. The housing should not be used as an end stop.
F4
Terminals
T6 Faston 2,03 0,5 6,6 long
T7 Solder 3,50 0,5 3,6 long
T8 PCB 0,8 0,5 4,0 long
Circuit
No symbol Change over
C2 Normally closed
C4 Normally open
Actuators
No symbol Without lever
Y1 Plain lever 21,0 mm
YC Cam follower lever 16,9 mm
Contacts
No symbol Fine silver
GP Gold plate on silver (GP)
Approvals
No symbol Without approval
UL UL and CSA approval
Ordering Reference
Burgess
[0.06]
1.6
[0.13]
3.4
Burgess
[0.83]
[0.3]
21.0
7.5
R2.4
Burgess
[0.09]
[0.3]
7.5
16.9
[0.67]
40621_Inhalt_029 14.10.2004 7:54 Uhr Seite 29