A16/M16 A16/M16
77
Precautions
WARNING
Do not apply a voltage between the incandescent lamp and
the
terminal that is greater than the rated voltage.
If the incan
-
descent
lamp is broken, the operating part may pop out.
Always turn OFF the power and wait for 10 minutes before
replacing the incandescent lamp. If the lamp is replaced
immediately
after the power is turned OFF
, the remaining heat
may cause burns.
Correct Use
Mounting
Always make sure that the power is turned OFF before mounting,
removing,
or wiring the Switch, or performing maintenance.
Do not tighten the mounting nut more than necessary using tools
such as pointed-nose pliers. Doing so will damage the mounting
nut.
The tightening torque is 0.29 to 0.49 N
⋅m.
Wiring
Solder
terminals and quick-connect terminals
(#1
10) are commonly
used
for terminals.
Be sure to use electrical wires that are a size appropriate for the
applied voltage and carry current (conductor size is 0.5 to 0.75
mm2). Perform soldering according to the conditions provided
below.
If the soldering is not properly performed, the lead wires will
become
detached, resulting in short-circuits.
1. Hand soldering: 30 W
, within 5 s
2. Dip soldering: 240
°
C, within 3 s
Wait for one minute after soldering before exerting any external
force
on the solder
.
Use non-corrosive resin fluid as the flux.
Make
sure that the electric cord is wired so that it does not touch the
Unit.
If the electric cord touches the Unit,
then electric wires with a
heat
resistance of 100
°
C min. must be used.
After wiring the Switch, maintain an appropriate clearance and
creepage
distance.
Operating Environment
The
IP65 model is designed with a protective
structure so that it will
not
sustain damage if it is subjected to water from any direction
to
the front of the panel.
Using the Microload
Insert
a contact protection
circuit, if necessary
, to prevent the reduc
-
tion
of life
expectancy due to extreme wear on the contacts caused
by loads where inrush current occurs when the contact is opened
and
closed.
The
A16 allows both a standard load (125 V at 5A, 250
V at 3 A) and
a microload. If a standard load is applied, however, the microload
area
cannot be used. If the
microload area is used with a standard
load, the contact surface will become rough, and the opening and
closing
of the contact for a microload may become unreliable.
The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level
of 60% (
λ
60) (conforming to JIS C5003).
The equation, λ 60 = 0.5 x 10–4/time indicates that the estimated
malfunction rate is less than 1/2,000,000 with a reliability level of
60%.
Area of use
Invalid
area
Voltage (V)
Current (mA)
LED
The LED current-limiting resistor is built-in, so internal resistance is
not
required.
Rated voltage Internal limiting resistor
5 VDC
33
Ω
(82
Ω)
12 VDC
270
Ω
(470
Ω)
24 VDC
1600
Ω
(2400
Ω)
Note: The
values in parentheses are for models with blue Push
-
button Units.
Others
The
oil-resistant IP65 uses NBR rubber and is resistant to general
cutting
oil and cooling oil. Some particular oils cannot be used with
the
oil-resistant IP65, however
, so contact your OMRON represen
-
tative
for details.
!