SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE
RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP.
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
DC CURRENT (Typ.)
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A, EAC TP TC 020
5 ~ 95% RH non-condensing
-40 ~ +85℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
254.1K hrs min. MIL-HDBK-217F (25 )℃
161*68*36mm (L*W*H)
0.563Kg; 24pcs/14.5Kg/0.91CUFT
File Name:RSD-100-SPEC 2020-10-20
100W Railway Single Output DC-DC Converter
■ Features :
RSD-100 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
SAFETY &
EMC
(Note 5)
ENVIRONMENT
PROTECTION
1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Strongly recommended that external output capacitance should not exceed 5000uF. :(Only for RSD-100-5 / -12)
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
※ Product Liability Disclaimer For detailed information, please refer to: https://www.meanwell.com/serviceDisclaimer.aspx
RSD-100B-5
RSD-100B-12 RSD-100C-12 RSD-100D-12
RSD-100B-24 RSD-100C-24
RSD-100D-24
RSD-100C-5 RSD-100D-5
5V 12V 24V 5V 12V 24V 5V 12V 24V
20A 8.4A 4.2A 20A 8.4A 4.2A 20A 8.4A 4.2A
0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A 0 ~ 20A 0 ~ 8.4A 0 ~ 4.2A
100W 100.8W 100.8W 100W 100.8W 100.8W 100W 100.8W 100.8W
100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p 100mVp-p 120mVp-p 150mVp-p
±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
±0.5% ±0.3% ±0.2% ±0.5% ±0.3% ±0.2% ±0.5% ±0.2% ±0.2%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
800ms, 50ms at full load
16.8 ~ 31.2VDC
14.4 ~ 33.6VDC
88%
4.8A/24V
89% 89% 89%
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
67.2 ~ 143VDC
57.6 ~ 154VDC
91% 91% 89.5% 91% 90%
4.8A/24V 4.8A/24V 2.4A/48V
30A/48VDC
2.4A/48V 2.4A/48V 1.2A/110V
30A/110VDC
1.2A/110V 1.2A/110V
30A/24VDC
Compliance to EN50155 and EN45545-2 railway standard
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Input reverse polarity
4000VDC I/O isolation
Cooling by free air convection
Half encapsulated
Built-in constant current limiting circuit
1U low profile 36mm
All using 105 long life electrolytic capacitors℃
LED indicator for power on
100% full load burn-in test
3 years warranty
5.75 ~ 7V 5.75 ~ 7V 5.75 ~ 7V13.8 ~ 16.2V 13.8 ~ 16.2V 13.8 ~ 16.2V27.6 ~ 32.4V 27.6 ~ 32.4V 27.6 ~ 32.4V
EMC IMMUNITY
EMC EMISSION
HOLD UP TIME (Typ.)
CONTINUOUS
1 SEC.
RAILWAY STANDARD EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC ;EN45545-2 for fire protection
-40 ~ +55 (no derating) ; +70 @ 60% load by free air convection ; +70 no derating with external base plate, TX class compliance℃℃ ℃
Protection type : Shut down o/p voltage, re-power on to recover
Please refer to page 3 Hold up Time( Load de-rating curve )
EN50155:2007-B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load ; D-type comply with S2 level @ full load
EN50155:2017-Comply with S1 level
INTERRUPTION OF VOLTAGE SUPPLY
UL62368-1 TPTC004 IEC62368-1
AS/NZS62368-1
OPERATING ALTITUDE 5000 meters
IEC 62368-1, UL 62368-1, approvedAS/NZS 62368-1, EAC TP TC 004