BIAS 1 Watt Power Supply BPW 1 Series Data Sheet Single (Vo) or Dual (Vo & Vr) output BPW 1-08-00, -08-33, -08-50 BPW 1-14-00, -14-33, -14-50 The BPS Power Supply Module is an ideal solution for numerous control applications in lighting, sensing, smart building/home and power distribution where operation from 277VAC mains is required. This low-cost supply provides up to one watt of output power at 8 or 14 VDC (Vo) and an optional 3.3 or 5 VDC (Vr) output for microprocessors, logic, timing circuits, transceivers, sensors or other control functions. A patented design incorporating a custom integrated circuit into a small package (0.55 in3 [9.0 cm3]) the BIAS Module provides an immediate "drop-in" solution, requiring no additional external components. (@120VAC / 60 Hz / 25C unless otherwise specified) Electrical Input Voltage Range 90 - 308 VAC (50/60Hz) Input Surge Withstand 345V, < 30 sec Output Power (Pmax) 1.0 W min. (60Hz) 0.83 W min. (50Hz) Efficiency 70% nom. Output Vo (Peak) 8 or 14 VDC nom. +/- 5% Line / Load Regulation Vo (Peak) +/- 1% Po < Pmax Temperature Regulation Vo (Peak) +/- 2% Po < Pmax Ripple Vo (@120 Hz) (@ 100 kHz) 1.00 V p:p 0.25 V p:p Output Vr, 3.3 volt (+/- 5%) For Vo = 8V, Ir out 53mA max, Io+Ir 125mA* For Vo = 14V, Ir out 23mA max, Io+Ir 71mA* Output Vr, 5.0 volt (+/- 5%) For Vo = 8V, Ir out 83mA max, Io+Ir 125mA* For Vo = 14V, Ir out 28mA max, Io+Ir 71mA* No-load Consumption 30 mW typical @ Vin=120 VAC Isolation 3000 VAC (meets UL / CSA & EN Product Safety) < 10 uA Continuous, Pin 0.6 w @ Vin = 120 VAC Reliability @ 25 C, MIL HDBK-217F > 500 Khr MTBF Thermal Operating Temperature -30 to +70o C Operating Relative Humidity 0 - 95%, non-condensing Storage Temperature -40 to +105o C Mechanical 1.10 x 0.92 x 0.55 inches [27.94 x 23.24 x 13.97 mm] Safety Safety Compliance UL / EN 60950-1 2nd Ed. (CB Report Available) EMI Emissions EN 55022, Class B, FCC Part 15, Class B BIAS Power * * * * * * * * Universal Input (90-308 VAC, 50/60Hz) Small Size--0.55in3 [9.0cm3] Low no-load input power <30mW Constant power mode, not current limit 3000 VAC Isolation Up to 75% efficiency EN 55022, Class B; FCC Part 15, Class B Meets UL/CSA and EN Product Safety Require- Auxiliary, where the Bias supply is one of two or more supplies and provides power for standby, housekeeping, biasing or other requirements. Generally, these supply 3.3V or 5.0V requirements from the Vr output. In some cases a small amount of Vo power is used. Second is as a main or utility supply where Bias is the only supply and provides all power necessary for the product or system. Both Vr and Vo supplies are often utilized for optimum system performance. The characteristics of the Vo and Vr outputs are different and each has application-specific benefits which can provide high value to the system designer. Short Circuit Protection Package Size (L x W x H) Features Bias Power AC/DC power supplies are designed to be applied in two major categories of applications... Operating Specifications Earth Leakage @ 120 VAC Actual Size Vo is a voltage-regulated output which has a constant power mode instead of a conventional current limit. This output is best suited to drive mechanical relays, solenoids, SSRs, capacitive loads, indicating lights, LEDs and as a source for isolated DC utility power which may be used directly or post-regulated with either a linear regulator or a DC/DC converter. Vo is self protecting, cannot be overloaded and can be shorted indefinitely. The graceful transition from voltage regulation to constant power along with the wide range of product ratings, allows the designer to select a supply tightly matched to the design load. There is no need to oversize a Bias Power supply. Unlike designyour-own, or partially complete modules where significant design margin is required, to stay far away from current limit, Bias's constant power alternative requires no such over-spec'ing. Vr is also a voltage-regulated output and is thermally protected from overload. It has very low output ripple capable of driving microprocessors , logic, transceivers, sensors and other elements which require a low-noise, tightly-regulated supply. In addition, Vr is supplied internally by Vo. This means that any capacitance added to Vo can increase the hold-up time of Vr as well. *Note: maximum currents specified for constant voltage range only. See V-I curve on page 2 for Vo in constant power range. BPW 1 Series Data Sheet, Page 1 of 5 Revised 01/26/2011 Specifications subject to change www.biaspower.com BIAS 1 Watt Power Supply BPW 1 Series Data Sheet Single (Vo) or Dual (Vo & Vr) output BPW 1-08-00, -08-33, -08-50 BPW 1-14-00, -14-33, -14-50 No Load Pow e r VS Input Voltage V-I, typical 130 110 90 Vo, volts Input Power (mW) 150 70 50 30 10 85 110 135 160 185 210 235 260 10 9 8 7 6 5 4 3 2 1 0 Constant Power Region 0 Input Voltage (Vac) 100 200 Io, mA 300 400 500 EMI, Conducted, dBV EMI, Radiated Signal Strength, typical, dBV/m Output Current(mA) 2000 1750 1500 1250 8V M ax Ipk 1000 14V m ax Ipk 750 500 250 0 0.000 2.083 4.165 6.248 Tim e(m S) BIAS Power 8.330 Vo, volts for 8, 14 volt ratings P eak R epetitive P ulse Lo ading Output Regulation, Vo 15 14 13 12 11 10 9 8 7 6 100% Load 50% Load 25% Load 0 8.3 BPW 1 Series Data Sheet, Page 2 of 5 Revised 01/26/2011 Specifications subject to change 16.6 24.9 Time, mSec 33.2 www.biaspower.com 41.5 49.8 BIAS 1 Watt Power Supply BPW 1 Series Data Sheet Single (Vo) or Dual (Vo & Vr) output BPW 1-08-00, -08-33, -08-50 BPW 1-14-00, -14-33, -14-50 Minim um Output Pow er VS Tem perature 60Hz 8V Model 1.15 1.30 85Vac 1.20 120Vac 1.10 240Vac 1.00 265Vac 0.90 0.80 Output Power (W) Output Power (W) 1.40 Typical Output Pow er VS Tem perature 60Hz 8V Model 85Vac 1.05 120Vac 240Vac 0.95 265Vac 0.85 0.75 0 10 20 30 40 50 60 70 0 10 Tem p (C) Typical Output Pow er VS Tem perature 50Hz 8V Model 20 30 40 50 60 Tem p (C) 70 Minim um Output Pow er VS Tem perature 50Hz 8V Model 85Vac 1.05 120Vac 0.95 240Vac 265Vac 0.85 0.75 Output Power (W) Output Power (W) 1.15 0.95 85Vac 120Vac 0.85 240Vac 265Vac 0.75 0.65 0 10 20 30 40 50 60 Tem p (C) BIAS Power 70 0 10 20 BPW 1 Series Data Sheet, Page 3 of 5 Revised 01/26/2011 Specifications subject to change 30 40 50 60 Tem p (C) 70 www.biaspower.com BIAS 1 Watt Power Supply BPW 1 Series Data Sheet Single (Vo) or Dual (Vo & Vr) output BPW 1-08-00, -08-33, -08-50 BPW 1-14-00, -14-33, -14-50 Minim um Output Pow er VS Tem perature 60Hz 14V Model 85Vac 1.30 120Vac 1.20 240Vac 1.10 265Vac 1.00 1.15 Output Power (W) Output Power (W) 1.40 Typical Output Pow er VS Tem perature 60Hz 14V Model 0.90 85Vac 120Vac 1.05 240Vac 0.95 265Vac 0.85 0.75 0 10 20 30 40 50 60 70 0 10 20 30 40 50 Tem p (C) Tem p (C) Minim um Output Pow er VS Tem perature 50Hz 14V Model Typical Output Pow er VS Tem perature 50Hz 14V Model 1.15 0.95 85Vac 1.05 120Vac 0.95 240Vac 0.85 265Vac Output Power (W) Output Power (W) 60 70 85Vac 0.85 120Vac 240Vac 0.75 265Vac 0.65 0.75 0 10 20 30 40 50 Tem p (C) BIAS Power 60 70 0 10 BPW 1 Series Data Sheet, Page 4 of 5 Revised 01/26/2011 Specifications subject to change 20 30 40 50 Tem p (C) 60 70 www.biaspower.com BIAS 1 Watt Power Supply BPW 1 Series Data Sheet Single (Vo) or Dual (Vo & Vr) output BPW 1-08-00, -08-33, -08-50 BPW 1-14-00, -14-33, -14-50 Part Number Designation Part Number Output Configuration Vo Vr BPW 1-08-00 Single output 8 VDC N/A BPW 1-14-00 Single output 14 VDC N/A BPW 1-08-33 Dual Output 8 VDC 3.3 VDC BPW 1-08-50 Dual Output 8 VDC 5 VDC BPW 1-14-33 Dual Output 14 VDC 3.3 VDC BPW 1-14-50 Dual Output 14 VDC 5 VDC For custom configurations, contact BIAS Power. PIN DESCRIPTION L1 Input High L2 Input Low N/C No Connection Vo Output GND Ground Vr Vr Output N/C No Connection Isolation, Bottom View Recommended Land Pattern, top view NOTES 1. Pins 0.031" [0.787 mm] round 2. Pins extend 0.125" [3.175 mm] below stand-offs BIAS Power BPW 1 Series Data Sheet, Page 5 of 5 Revised 01/26/2011 Specifications subject to change www.biaspower.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: BIAS Power: BPW 1-05-00 BPW 1-05-33 BPW 1-08-00 BPW 1-08-33 BPW 1-08-50 BPW 1-12-00 BPW 1-12-33 BPW 1-12-50 BPW 1-14-00 BPW 1-14-33 BPW 1-14-50 BPW 1-24-00 BPW 1-24-33 BPW 1-24-50