1 Hour (R1) Max. Time Tripped
Ihold Itrip Initial Post-Trip To Trip Power
Resistance Resistance Dissipation
Model Amperes Ohms Ohms Amperes Seconds Watts
V max. I max.
at 23°C at 23°C at 23°C at 23°C at 23°C at 23°C
Volts Amps
Hold Trip Min. Max. Max.
MF-RG300 16 100 3.00 5.10 0.032 —0.105 15.0 2.0 2.3
MF-RG500 16 100 5.00 8.50 0.015 —0.044 25.0 3.6 2.6
MF-RG700 16 100 7.00 11.90 0.008 —0.021 35.0 8.0 3.0
MF-RG900 16 100 9.00 15.30 0.004 —0.015 45.0 12.0 3.3
MF-RG1100 16 100 11.00 18.70 0.003 —0.010 55.0 15.2 3.7
Electrical Characteristics
Features
■Radial Leaded Devices
■Smaller size for similar Ihold rating
■Faster tripping
■Tighter trip-to-hold ratios
■Bulk packaging, tape and reel and Ammo-
Pak available on most models
■Patents pending
■Agency recognition:
(pending)
Applications
■Automotive
■Computers and peripherals
■General electronics
■Wire harnesses
Operating/Storage Temperature ........................-40°C to +85°C
Maximum Device Surface Temperature
in Tripped State ................................................125°C
Passive Aging......................................................+85°C, 1000 hours ......................................±5% typical resistance change
Humidity Aging....................................................+85°C, 85% R.H. 1000 hours......................±5% typical resistance change
Thermal Shock ....................................................+125°C to -55°C, 10 times..........................±10% typical resistance change
Solvent Resistance ............................................MIL-STD-202, Method 215 ........................No change
Vibration ..............................................................MIL-STD-883C, Method 2007.1, ................No change
Condition A
Environmental Characteristics
Test Test Conditions Accept/Reject Criteria
Visual/Mech. ......................................................Verify dimensions and materials..................Per MF physical description
Resistance ..........................................................In still air @ 23°C ........................................Rmin ≤R ≤Rmax
Time to Trip ........................................................5 times Ihold, Vmax, 23°C ..........................T ≤max. time to trip (seconds)
Hold Current ......................................................30 min. at Ihold............................................No trip
Trip Cycle Life ....................................................Vmax, Imax, 100 cycles ..............................No arcing or burning
Trip Endurance....................................................Vmax, 48 hours ..........................................No arcing or burning
UL File Number ..................................................E 174545S*
CSA File Number ................................................CA 110338
TÜV File Number ................................................R2057213
Test Procedures And Requirements For Model MF-RG Series
Thermal Derating Chart - Ihold (Amps)
Ambient Operating Temperature
Model -40˚C -20˚C0˚C23˚C40˚C50˚C60˚C70˚C85˚C
MF-RG300 4.4 4.0 3.6 3.0 2.6 2.4 2.1 1.9 1.4
MF-RG500 7.3 6.6 6.0 5.0 4.4 4.0 3.6 3.1 2.4
MF-RG700 10.3 9.3 8.4 7.0 6.2 5.6 5.0 4.4 3.3
MF-RG900 13.2 11.9 10.7 9.0 7.9 7.2 6.4 5.6 4.2
MF-RG1100 14.7 13.3 12.0 10.0 8.7 8.0 7.0 6.3 4.7
*Itrip is approximately two times Ihold.
PRELIMINARY