NJU7261 Series
-1-
Ver.2003-07-18
PRELIMINAR
Y
C-MOS STEP-UP SWITCHING REGULATOR
GENERAL DESCRIPTION PACKAGE OUTLINE
The NJU7261 series is a C-MOS step-up switching regulator
which contains accurate voltage reference, error amplifier, CR
oscillator, control circuit, switching transistor, diode and resistor.
The stand-by function is effective for low power consumption.
The regulation voltage is fixed by internal circuits and the following
line-up of different output voltages version are available.
This series is suitable for portable equipment's or battery operated
items because of its small packaged outline, low operating voltage
and current.
FEATURES PIN CONFIGULATION
Low Operating Voltage (1.0V min.)
Low Operating Current (5.0µA typ. / VOUT = 3.0V)
Low Stand-by Current (0.2µA max. / VOUT = 3.0V)
High Precision Output Voltage (±3% max.)
Wide Operating Voltage Range
Stand-by Function
CR Oscillator On-chip
Diode On-chip
Package Outline SOT89-5
C-MOS Technology
LINE-UP EQUIVALENT CIRCUIT
Output Voltage (V) Line-Up
3.0 NJU7261U30
3.3 NJU7261U33
4.5 NJU7261U45
5.0 NJU7261U50
TERMINAL DESCRIPTION
No. Term. Name I/O FUNCTION
1 CONT I External Inductor Connect Terminal
2 GND POWER Power Source (GND)
3 STB I
Strobe Terminal : "H" or OPEN···Normal Operation (step-up)
" L" ···Standp-By Operation
4 VIN POWER Power Source (+)
5 VOUT O Step-up Output Terminal
NJU7261UX
NJU7261 Series
- 2 - Ver.2003-07-18
ABSOLUTE MAXIMUM RATINGS (Ta = 25ºC)
PARAMETER SYMBOL RATINGS UNIT
Input Voltage VIN 10 V
CONT Input Voltage VCONT GND-0.3 VCONT 10 V
Strobe Input Voltage VSTB GND-0.3 VSTB VIN V
Output Voltage VOUT GND-0.3 VOUT 10 V
Power Dissipation PD 300 mW
Operating Temperature Range Topr -25 to + 75 ºC
Storage Temperature Range Tstg -40 to +125 ºC
Note1) When a coil used. This IC of VCONT possible over the absolute maximum ratings. Consequently please conduct
enough to test.
Note2) The CONT input voltage (VCONT) should be inspected at the real application circuit, as some kinds of coils make
the CONT input voltage exceed the Absolute Maximum Rating of the VCONT.
ELECTRICAL CHARACTERISTICS
+3.0V Version (T
a = 25°C)
NORM
PARAMETER SYMBOL CONDITION
MIN. TYP. MAX.
UNIT
MEASUREMENT
CIRCUIT
Input Voltage VIN - - 5.0 V 1
Start Voltage VSTART NO LOAD - - 1.0 V 1
Oscillator Freq. fOSC V
IN = 1.5V 20 30 50 kHz 2
Output Voltage VOUT V
IN = 1.5V, IOUT = 20mA 2.91 3.0 3.09 V 1
Input Stability VOUT1 VIN = 1.5V to 2.0V
IOUT = 20mA - 30 100 mV 1
Load Stability VOUT2 VIN = 1.5V
IOUT = 10µA to 25mA - 30 100 mV 1
Operating Current ISS V
IN = VSTB = 1.5V, NO LOAD - 5.0 10 µA 3
Stand-by Current IQ VIN = 1.5V
VSTB = 0V, NO LOAD - - 0.2 µA 4
Switching Current ISI V
DS = 0.2V - 250 - mA -
H level VSTBH V
IN = 1.5V 1.0 - - V 5
STB Terminal
Input Voltage L level VSTBL V
IN = 1.5V - - 0.4 V 5
ISTBH1 V
IN = 1.5V, VSTB = 1.0V - 15 30 µA 6
H level ISTBH2 V
IN = 1.5V, VSTB = 1.5V - 0.1 - µA 6
ISTBL1 V
IN = 1.5V, VSTB = 0.4V - 15 30 µA 6
STB Terminal
Input Current
L level ISTBL2 V
IN = 1.5V, VSTB = 0V - 0.1 - µA 6
NJU7261 Series
-
3
-
Ver.2003-07-18
+3.3V Version (T
a = 25°C)
NORM
PARAMETER SYMBOL CONDITION
MIN. TYP. MAX.
UNIT
MEASUREMENT
CIRCUIT
Input Voltage VIN - - 5.0 V 1
Start Voltage VSTART NO LOAD - - 1.0 V 1
Oscillator Freq. fOSC V
IN = 1.5V 20 30 50 kHz 2
Output Voltage VOUT V
IN = 1.5V, IOUT = 20mA 3.20 3.30 3.40 V 1
Input Stability VOUT1 VIN = 1.5V to 3.0V
IOUT = 20mA - 30 100 mV 1
Load Stability VOUT2 VIN = 1.5V
IOUT = 10µA to 25mA - 30 100 mV 1
Operating Current ISS V
IN = VSTB = 1.5V, NO LOAD - 5 10 µA 3
Stand-by Current IQ VIN = 1.5V
VSTB = 0V, NO LOAD - - 0.2 µA 4
Switching Current ISI V
DS = 0.2V - 250 - mA -
H level VSTBH V
IN = 1.5V 1.0 - - V 5
STB Terminal
Input Voltage L level VSTBL V
IN = 1.5V - - 0.4 V 5
ISTBH1 V
IN = 1.5V, VSTB = 1.0V - 15 30 µA 6
H level ISTBH2 V
IN = 1.5V, VSTB = 1.5V - 0.1 - µA 6
ISTBL1 V
IN = 1.5V, VSTB = 0.4V - 15 30 µA 6
STB Terminal
Input Current
L level ISTBL2 V
IN = 1.5V, VSTB = 0V - 0.1 - µA 6
+4.5V Version (T
a = 25°C)
NORM
PARAMETER SYMBOL CONDITION
MIN. TYP. MAX.
UNIT
MEASUREMENT
CIRCUIT
Input Voltage VIN - - 4.5 V 1
Start Voltage VSTART NO LOAD - - 1.0 V 1
Oscillator Freq. fOSC V
IN = 3.0V 20 30 50 kHz 2
Output Voltage VOUT V
IN = 3.0V, IOUT = 20mA 4.36 4.50 4.64 V 1
Input Stability VOUT1 VIN = 2.0V to 3.0V
IOUT = 20mA - 30 100 mV 1
Load Stability VOUT2 VIN = 3.0V
IOUT = 10µA to 25mA - 30 100 mV 1
Operating Current ISS V
IN = VSTB = 3.0V, NO LOAD - 5 15 µA 3
Stand-by Current IQ VIN = 3.0V
VSTB = 0V, NO LOAD - - 0.2 µA 4
Switching Current ISI V
DS = 0.2V - 250 - mA -
H level VSTBH V
IN = 3.0V 2.4 - - V 5
STB Terminal
Input Voltage L level VSTBL V
IN = 3.0V - - 0.4 V 5
ISTBH1 V
IN = 3.0V, VSTB = 2.4V - 50 100 µA 6
H level ISTBH2 V
IN = 3.0V, VSTB = 3.0V - 0.1 - µA 6
ISTBL1 V
IN = 3.0V, VSTB = 0.4V - 50 100 µA 6
STB Terminal
Input Current
L level ISTBL2 V
IN = 3.0V, VSTB = 0V - 0.1 - µA 6
NJU7261 Series
- 4 - Ver.2003-07-18
+5.0V Version (T
a = 25°C)
NORM
PARAMETER SYMBOL CONDITION
MIN. TYP. MAX.
UNIT
MEASUREMENT
CIRCUIT
Input Voltage VIN - - 5.0 V 1
Start Voltage VSTART NO LOAD - - 1.0 V 1
Oscillator Freq. fOSC V
IN = 3.0V 20 30 50 kHz 2
Output Voltage VOUT V
IN = 3.0V, IOUT = 20mA 4.85 5.0 5.15 V 1
Input Stability VOUT1 VIN = 2.0V to 3.0V
IOUT = 20mA - 30 100 mV 1
Load Stability VOUT2 VIN = 3.0V
IOUT = 10µA to 25mA - 30 100 mV 1
Operating Current ISS V
IN = VSTB = 3.0V, NO LOAD - 5 15 µA 3
Stand-by Current IQ VIN = 3.0V
VSTB = 0V, NO LOAD - - 0.2 µA 4
Switching Current ISI V
DS = 0.2V - 250 - mA -
H level VSTBH V
IN = 3.0V 2.4 - - V 5
STB Terminal
Input Voltage L level VSTBL V
IN = 3.0V - - 0.4 V 5
ISTBH1 V
IN = 3.0V, VSTB = 2.4V - 50 100 µA 6
H level ISTBH2 V
IN = 3.0V, VSTB = 3.0V - 0.1 - µA 6
ISTBL1 V
IN = 3.0V, VSTB = 0.4V - 50 100 µA 6
STB Terminal
Input Current
L level ISTBL2 V
IN = 3.0V, VSTB = 0V - 0.1 - µA 6
NJU7261 Series
-
5
-
Ver.2003-07-18
MEASUREMENT CIRCUIT 1
(1)
External Diode Type : "D1NS4" provided by SHINDENGEN
(I
F = 1A, VF = 0.55V)
(2)
(3)
I
SS = I1 + l2 x
2
OUT
V
V
Under the condition of V2 =VOUT + 1.0V
NJU7261 Series
-
6
- Ver.2003-07-18
MEASUREMENT CIRCUIT 2
(4)
(5)
(6)
NJU7261 Series
-7-
Ver.2003-07-18
APPLICATION CIRCUIT
NJU7261 Series
-
8
- Ver.2003-07-18
TYPICAL CHARACTERISTIC
Start Voltage vs. Temperature Start Voltage vs. Temperature
Internal Oscillator Operation : External D1NS4 Internal Oscillator Operation : External D1NS4
Oscillation Frequency vs. Temperature Oscillation Frequency vs. Temperature
[CAUTION]
The specifications on this databook are only
given for information , without any guarantee
as regards either mistakes or omissions. The
application circuits in this databook are
described only to show representative usages
of the product and not intended for the
guarantee or permission of any right including
the industrial rights.