Astec Industry Standard 130 Watts [vase APH Series [mmaianiinait High Efficiency PRELIMINARY Electrical Specs Input Input range 35-75 VDC Input Surge 100V / 100ms Efficiency 92% (Typ), 90% (Min) Control Voltage Adjust (Optional) 90 to 110% Enable TTL compatible (positive) Ser ease ial igs Output Regulation : . : (All Conditions; High efficiency, 92% (Typical) Line, Load, Temp) <5% down to no load e -25C to +65C operating temperature (no derating) Ripple and noise 2% typical (200mV p-p max) Positive Enable function Low output ripple and noise - Output voltage * Protection (OVP, OCP, OTP) adjust range +/-10% of nominal output Auto-recovery * Regulation to zero load Overvoltage Protection | 130% nominal output Fixed frequency switching (400 kHz) Current Limit Inception 22.5 Amps Environmental | Notes: # Nominal values apply with sense pins connected Operating temperature (ambient): : and other control pins unconnected. -25C to +65C (No Derating) Specifications subject to change without notice. -40C to +85C (Contact Factory for Derating Curve) # Storage temperature: -55C to +105C Overtemperature protection: 125C PCB MTTF: >1.5 million hours UL 60950: 2000, Recognized CSA (22.2 No. 60950 Certified TUV EN60950 12 Americas (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662 ASTECAMERICAS EUROPE ASIA 5810 Van Allen Way Astec House, Waterfront Business Park Units 2141-2116, Level 21 Carisbad, CA 92008 Merry Hill, Dudley Tower1, Metroplaza Telephone: 760-930-4600 West Midlands, DY5 1LX, UK 223, Hing Fong Road Facsimile: 760-930-0698 Telephone: 44 (1384) 842-211 Fwai Fong, New Territories ASTEC Facsimile: 44 (1384) 843-355 Hong Kong Telephone: $52-2437-9662 Facsimile: 852-2402-4426 > u , = Ordering Information > Input Output Efficiency Model Number Package Voltage Voltage 48V 7.25V @ 18A 92% APH18E48 Open frame, half brick 48V 12V @ 10A 92% APH10E48 Open frame, half brick : Note: Efficiency is measured at full load and Ta = 25 Deg C -9 Suffix added for Trim Option Maas Tolerances: x.xx +/- 0.02 in (x.x +/- 0.5mm) X.xxx +/- 0.010 in (x.xx +/- 0.25mm Single Output Height: 0.43 1. -Vin 2. No Connect 3. Enable (on/off) 4. +Vin 5. -QOutput 6. No Connect 7. No Connect (Optional Trim -9) 8. No Connect _ 9. + Output 0.43 (see Notes: 1. 20 mHz bandwidth. An external 2.2 mf ceramic capacitor is recommended to be placed from +V out to -V out. # 2. Requires a 2.2 mf, 100V film capacitor connected between +V in : and -V in to meet FCC class A and ETS300-386-1 requirements for r+ conducted noise. Consult Factory for filtering information to 2.30 [58.43] | 1.000 j meet FCC class B, VDE or EIC specifications. 240 2000 1.400 asoa_| iM 3. All specifications are typical at nominal line, full load, and 25C [61.00] [50.800] [35.560] rao) +~ T+ unless otherwise noted. a 4. All specifications subject to change without notice. Mechanical L 94 drawings are for reference only. 1 5. Please refer to the Technical Reference Notes for more information. 6 Mounting Inserts . Warranty: lyr M3 X 2.5 (4 places) p4ippupjs Aijsnpuy 3a3sy EMERSON www.astec.com Network Power 13