G-18
FLOW SWITCHES
Visit www.GemsSensors.com for most current information.
Model Port Size
NPT
A
inch (mm)
B
inch (mm)
C Hex
inch (mm)
FS-200
and
FS-200
Adjustable
1˝ 3-1/4 (82.6) 3 (76.2) 1-25/32 (45.2)
1-1/4˝ 4 (101.6) 3-3/16 (80.9) 2-3/16 (55.5)
1-1/4˝ ss 4-1/2 (114.3) 3-3/16 (80.9) 2-3/16 (55.5)
1-1/2˝ 4-1/2 (114.3) 3-1/2 (88.9) 2-1/2 (63.5)
2˝ 5-3/8 (136.5) 4 (101.6) 3-3/32 (78.5)
UL Approved
Explosion-Proof
A
B
1/2" -NPT
BONNET
SWITCH
HOUSING
NPT PORT
INLET PORT
C
#18 AWG., 24" L.,
POLYMERIC JACKET
G-4 ill
FS-200 Series – General Purpose,
Straight-Through Flow Path
Flow Rate Settings: Fixed: 0.5 GPM to 100.0 GPM
Adjustable: 1.0 GPM to 15.0 GPM
Port Size: 1˝ NPT to 2˝ NPT
Primary Construction Material: Bronze or Stainless Steel
Setting Type: Fixed or Adjustable
The FS-200 Series offers accurate flow detection, with 1% repeatability, over a broad
range of flow settings and port sizes. Its durable construction delivers long-life
reliability in either water or oil. Generous flow paths keep pressure drop low. These
switches are ideal for detection of improper flow rates in high volume lubrication,
cooling or process systems.
FS-200 Adjustable Series switches offer the same accuracy and are as rugged as those
with fixed settings, but provide one additional feature: external adjustability. With these
versatile switches your choice of flow settings is diverse within a given range. An
ordinary, flat-blade screwdriver is all that’s required for the actuation adjustment.
Specifications
Wetted Materials
Housing
FS-200 Bronze or 316 Stainless Steel
FS-200 Adjustable Bronze
Shuttle Teflon®
Bonnet Bronze or Stainless Steel
Spring 316 Stainless Steel
Other Wetted Parts Viton®, Ceramic
Pressure Rating
Operating 400 PSIG (27.6 bar) @ 100°F (37.8°C)
Proof 800 PSIG (55.2 bar) @ 100°F (37.8°C)
Operating Temperature
FS-200 -20°F to +300°F (-29°C to +148.9°C)
FS-200 Adjustable -20°F to +200°F (-29°C to +93.3°C)
Repeatability 1% Maximum Deviation
Set Point Accuracy ±10%
Set Point Differential 15% Maximum
Switch* SPDT, 20 VA
Electrical Termination No. 18 AWG, 24˝ L., Polymeric Lead Wires
Red NC, Black Common, Orange NO
*See “Electrical Data” on Page X-5 for more information.
FS-200 Series
U.L. Recognized
File No. E31926
CSA Listed —
File No. LR30200
and LR22666
FM Approved —
File No. 0A8A3.AE
and 1H3A2.AX
FS-200 Adjustable
U.L. Recognized
File No. E31926
CSA Listed —
File No. LR22666
FM Approved —
File No. 0Q2A8.AE
Dimensions
Notes:
1. Adjustable versions available in 1 inch port sizes only.
2. Standard calibration is in water with units in a horizontal position.
3. Viscosity changes will affect setpoints. Typically, as viscosity
increases setpoints will decrease.
4. Consult Gems for special applications.