© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com T2006_T492 • 6/19/2013 55
Tantalum Surface Mount Capacitors – MIL–PRF (CWR Style) Established Reliability
T492 Series CWR11 Style MIL–PRF–55365/8
42.2 A/3216-18 T492A225(1)004(2)(3)(4) CWR11C(6)225(1)(2)(5) 0.5 6.0 8.0 1
44.7 A/3216-18 T492A475(1)004(2)(3)(4) CWR11C(6)475(1)(2)(5) 0.5 6.0 8.0 1
46.8 B/3528-21 T492B685(1)004(2)(3)(4) CWR11C(6)685(1)(2)(5) 0.5 6.0 5.5 1
410 B/3528-21 T492B106(1)004(2)(3)(4) CWR11C(6)106(1)(2)(5) 0.5 6.0 4.0 1
415 B/3528-21 T492B156(1)004(2)(3)(4) CWR11C(6)156(1)(2)(5) 0.6 6.0 3.5 1
433 C/6032-28 T492C336(1)004(2)(3)(4) CWR11C(6)336(1)(2)(5) 1.3 6.0 2.2 1
468 D/7343-31 T492D686(1)004(2)(3)(4) CWR11C(6)686(1)(2)(5) 2.7 6.0 1.1 1
4100 D/7343-31 T492D107(1)004(2)(3)(4) CWR11C(6)107(1)(2)(5) 4.0 8.0 0.9 1
61.5 A/3216-18 T492A155(1)006(2)(3)(4) CWR11D(6)155(1)(2)(5) 0.5 6.0 8.0 1
62.2 A/3216-18 T492A225(1)006(2)(3)(4) CWR11D(6)225(1)(2)(5) 0.5 6.0 8.0 1
63.3 A/3216-18 T492A335(1)006(2)(3)(4) CWR11D(6)335(1)(2)(5) 0.5 6.0 8.0 1
64.7 B/3528-21 T492B475(1)006(2)(3)(4) CWR11D(6)475(1)(2)(5) 0.5 6.0 5.5 1
66.8 B/3528-21 T492B685(1)006(2)(3)(4) CWR11D(6)685(1)(2)(5) 0.5 6.0 4.5 1
610 B/3528-21 T492B106(1)006(2)(3)(4) CWR11D(6)106(1)(2)(5) 0.6 6.0 3.5 1
615 C/6032-28 T492C156(1)006(2)(3)(4) CWR11D(6)156(1)(2)(5) 0.9 6.0 3.0 1
622 C/6032-28 T492C226(1)006(2)(3)(4) CWR11D(6)226(1)(2)(5) 1.3 6.0 2.2 1
647 D/7343-31 T492D476(1)006(2)(3)(4) CWR11D(6)476(1)(2)(5) 2.8 6.0 1.1 1
668 D/7343-31 T492D686(1)006(2)(3)(4) CWR11D(6)686(1)(2)(5) 4.1 6.0 0.9 1
10 1A/3216-18 T492A105(1)010(2)(3)(4) CWR11F(6)105(1)(2)(5) 0.5 4.0 10.0 1
10 1.5 A/3216-18 T492A155(1)010(2)(3)(4) CWR11F(6)155(1)(2)(5) 0.5 6.0 8.0 1
10 2.2 A/3216-18 T492A225(1)010(2)(3)(4) CWR11F(6)225(1)(2)(5) 0.5 6.0 8.0 1
10 3.3 B/3528-21 T492B335(1)010(2)(3)(4) CWR11F(6)335(1)(2)(5) 0.5 6.0 5.5 1
10 4.7 B/3528-21 T492B475(1)010(2)(3)(4) CWR11F(6)475(1)(2)(5) 0.5 6.0 4.5 1
10 6.8 B/3528-21 T492B685(1)010(2)(3)(4) CWR11F(6)685(1)(2)(5) 0.7 6.0 3.5 1
10 15 C/6032-28 T492C156(1)010(2)(3)(4) CWR11F(6)156(1)(2)(5) 1.5 6.0 2.5 1
10 33 D/7343-31 T492D336(1)010(2)(3)(4) CWR11F(6)336(1)(2)(5) 3.3 6.0 1.1 1
10 47 D/7343-31 T492D476(1)010(2)(3)(4) CWR11F(6)476(1)(2)(5) 4.7 6.0 0.9 1
15 0.68 A/3216-18 T492A684(1)015(2)(3)(4) CWR11H(6)684(1)(2)(5) 0.5 4.0 12.0 1
15 1A/3216-18 T492A105(1)015(2)(3)(4) CWR11H(6)105(1)(2)(5) 0.5 4.0 10.0 1
15 1.5 A/3216-18 T492A155(1)015(2)(3)(4) CWR11H(6)155(1)(2)(5) 0.5 6.0 8.0 1
15 2.2 B/3528-21 T492B225(1)015(2)(3)(4) CWR11H(6)225(1)(2)(5) 0.5 6.0 5.5 1
15 3.3 B/3528-21 T492B335(1)015(2)(3)(4) CWR11H(6)335(1)(2)(5) 0.5 6.0 5.0 1
15 4.7 B/3528-21 T492B475(1)015(2)(3)(4) CWR11H(6)475(1)(2)(5) 0.7 6.0 4.0 1
15 10 C/6032-28 T492C106(1)015(2)(3)(4) CWR11H(6)106(1)(2)(5) 1.5 6.0 2.5 1
15 22 D/7343-31 T492D226(1)015(2)(3)(4) CWR11H(6)226(1)(2)(5) 3.3 6.0 1.1 1
15 33 D/7343-31 T492D336(1)015(2)(3)(4) CWR11H(1)336(1)(2)(5) 5.0 6.0 0.9 1
20 0.47 A/3216-18 T492A474(1)020(2)(3)(4) CWR11J(6)474(1)(2)(5) 0.5 4.0 14.0 1
20 0.68 A/3216-18 T492A684(1)020(2)(3)(4) CWR11J(6)684(1)(2)(5) 0.5 4.0 12.0 1
20 1A/3216-18 T492A105(1)020(2)(3)(4) CWR11J(6)105(1)(2)(5) 0.5 4.0 10.0 1
20 1.5 B/3528-21 T492B155(1)020(2)(3)(4) CWR11J(6)155(1)(2)(5) 0.5 6.0 6.0 1
20 2.2 B/3528-21 T492B225(1)020(2)(3)(4) CWR11J(6)225(1)(2)(5) 0.5 6.0 5.0 1
20 3.3 B/3528-21 T492B335(1)020(2)(3)(4) CWR11J(6)335(1)(2)(5) 0.7 6.0 4.0 1
20 4.7 C/6032-28 T492C475(1)020(2)(3)(4) CWR11J(6)475(1)(2)(5) 0.9 6.0 3.0 1
20 6.8 C/6032-28 T492C685(1)020(2)(3)(4) CWR11J(6)685(1)(2)(5) 1.4 6.0 2.4 1
20 15 D/7343-31 T492D156(1)020(2)(3)(4) CWR11J(6)156(1)(2)(5) 3.0 6.0 1.1 1
20 22 D/7343-31 T492D226(1)020(2)(3)(4) CWR11J(6)226(1)(2)(5) 4.4 6.0 0.9 1
25 0.33 A/3216-18 T492A334(1)025(2)(3)(4) CWR11K(6)334(1)(2)(5) 0.5 4.0 15.0 1
25 0.47 A/3216-18 T492A474(1)025(2)(3)(4) CWR11K(6)474(1)(2)(5) 0.5 4.0 14.0 1
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET part number, insert B = Gold Plated, C = Hot solder dipped, H or S = Solder Plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = -55°C +85°C after Weibull, or 4252 = -55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = -55°C +85°C after Weibull, C = -55°C +85°C before Weibull or Z = None. Designates Surge
current option.
(6) To complete CWR part number, insert B = Gold Plated, C = Hot Solder Dipped, H = Solder Plated or K = Solder Fused. Designates Termination Finish.
Refer to Ordering Information for additional detail.