Series IAC, (S)MIAC, X4IAC AC Input Modules * Status Indicating LED on X4 Series * UL, CSA, and CE Solid state I/O switching modules deliver an electrically clean, photo-isolated, noise-free "output" interface from logic level control systems to external loads such as motors, valves, solenoids, etc. -- or an "input" interface from the load or sensors to microprocessor or computer-based logic level systems. Designed for long, reliable service in demanding industrial environments. INPUT SPECIFICATIONS IAC5 (S)M IAC5 X4IAC5 IAC15 (S)M IAC15 X4IAC15 IAC24 (S)M IAC24 X4IAC24 IAC5A (S)M IAC5A X4IAC5A Nominal input voltage [Vrms/Vdc] 120 120 120 240 240 240 Minimum Input Voltage [Vrms/Vdc] 90 90 90 180 180 180 Maximum Input Voltage [Vrms/Vdc] 140 140 140 280 280 280 Maximum Input Current [mA rms] 10 10 10 8 8 8 Drop Out Current [mA rms] 2.5 2.5 2.5 1.5 1.5 1.5 Allowable Off-state Current [mA rms] 3.0 3.0 3.0 2.0 2.0 2.0 50.0 50.0 50.0 120 120 120 5 15 24 5 15 24 Allowable Off-state Voltage [Vrms/Vdc] IAC15A (S)M IAC15A X4IAC15A IAC24A (S)M IAC24A X4IAC24A OUTPUT SPECIFICATIONS Nominal Logic Voltage [Vdc] Minimum Logic Voltage [Vdc] (X4 Series) 1.5 (3) 8.5 (10) 16.5 (18) 1.5 (3) 8.5 (10) 16.5 (18) Maximum Logic Voltage [Vdc] (X4 Series) 6.0 (7) 18.5 (20) 30.5 (32) 6.0 (7) 18.5 (20) 30.5 (32) Typical Logic Supply Current [mAdc] 10 10 10 10 10 10 Max. Logic Supply Current [mAdc] 18.5 16 14 18.5 16 14 Max. Logic Sup. Leak. Current [Adc] 10 10 10 10 10 10 Maximum Output Voltage [Vdc] 30 30 30 30 30 30 Maximum Output Current [mAdc] 50 50 50 50 50 50 Max. Output Leakage Current [Adc] 10 10 10 10 10 10 Max. Output Voltage Drop [mVdc] 200 200 200 200 200 Maximum Turn-on Time [msec] 20 20 20 20 20 20 Maximum Turn-off Time [msec] 30 30 30 30 30 30 200 (c) 2003 CRYDOM CORP Specifications subject to change without notice. FastFax Document No. 302 SERIES IDC. Rev. 111803 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 * FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series IAC, (S)MIAC, X4IAC AC Input Modules GENERAL SPECIFICATIONS Operating temperatue ranger -30 to +80C Storage temperature range -40 to +100C Isolation 4,000 V rms 8 pF Capacitance input to output 47 to 63 Hz Line frequency range Package Color Yellow W IRING & M ECHANICAL DIAGRAM S Standard and M ini Pack Standard Series, IAC BOTTOM VIEW 1 .30 (7.6) CAPTIVE #4-40. PHILLIPS HEAD HOLD DOWN SCREW 1.70 (43.1) .60 (15.2) 1.00 (25.4) Vac/dc + 3 2 1 Schmitt Trigger OUT 4 - GND .030 (0.8) LOGIC 3 OUT 4 2 2 LOGIC 5 1 Vac/dc .100 (2.5) 1.25 (31.7) .25 (6.3) X4 Series GND + 3 Schmitt Trigger 4 5 5 .30 (7.6) .040 (1.0) DIA. (5 PLACES) .70 (17.8) X4 Series, X4IAC 1.20 (30.5) 1.40 (35.5) 1.60 (40.6) M INI-PACK Series, (S)M IAC SM Prefix M Prefix 0.81 (20.6) 0.20 (5.1) CAPTIVE #4-40. PHILLIPS HEAD HOLD DOWN SCREW APPLICATION NOTES Do not install or remove modules in live (electrically hot) circuits. CAPTIVE #4-40. PHILLIPS HEAD HOLD DOWN SCREW 1.00 (25.4) High voltage may be present. An externally located 1.70 (43.1) 1.70 (43.1) 1.78 (45.2) 1.00 (25.4) 1.00 (25.4) commutating diode must be installed across inductive loads .25 (6.35) 5 4 3+ 2 .25 (6.35) 1 I/O module boards also available 5 4 3+ 2 1 .30 (7.6) .30 (7.6) .200 (5.1) .700 (17.8) 1.100 (27.9) 1.30 (43.1) 1.70 (43.1) BOTTOM VIEW .040 (1.0) DIA. (5 PLACES) .100 (2.5) 1.82 (46.2) .200 (5.1) .700 (17.8) 1.100 (27.9) 1.30 (43.1) 1.70 (43.1) .040 (1.0) DIA. (5 PLACES) .040 (1.0) DIA. (5 PLACES) 0.15 (3.8) BOTTOM VIEW 0.35 (8.9) .40 (10.2) .40 (10.2) All dimensions are in inches (millimeters) 0.48 (12.2) .100 (2.5) 0.55 (13.9) 0.20 (5.1) 1.3 (33.0) 1.70 (43.1) (c) 2003 CRYDOM CORP Specifications subject to change without notice. FastFax Document No. 302 SERIES IDC. Rev. 111803 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 * FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506