SINGLE-POLE SINGLE-THROW SWITCHES
FEATURES
• Multioctave bands 0.2 to 18 GHz
• Current or TTL control
• Low insertion loss
• High isolation
• Ultra high speed models (5 ns) available
• Drop-in models available
Frequency
Insertion Rise/Fall On/Off On/Off DC Power
Range Model Loss Isolation VSWR* Time Time Time Positive Negative
(GHz) Number (dB, Max.) (dB, Min.) (Max.) Type (ns, Typ.) (ns, Typ.) (ns, Max.) (mA, Max.) (mA, Min.)
STANDARD, MULTIOCTAVE BAND MODELS
SW1-002020RN1NF 1.7 70 1.6:1 Reflective 10/10 20 35 35 70
0.2–2 SW1-002020AN1NF 1.8 75 1.6:1 Absorptive 10/10 20 35 35 70
0.5–2 SW1-005020RN1NF 1.5 80 1.6:1 Reflective 10/10 20 35 35 70
SW1-005020AN1NF 1.7 75 1.6:1 Absorptive 10/10 20 35 35 70
SW1-020080RN1NF 2 80 1.7:1 Reflective 10/10 20 35 35 70
2–8 SW1-020080AN1NF 2.2 70 1.7:1 Absorptive 10/10 20 35 35 70
4–12 SW1-040120RN1NF 2.2 80 1.7:1 Reflective 10/10 20 35 35 70
SW1-040120AN1NF 2.6 65 1.7:1 Absorptive 10/10 20 35 35 70
2–18 SW1-020180RN1NF 3 80 2:1 Reflective 10/10 20 35 35 70
SW1-020180AN1NF 3 60 2:1 Absorptive 10/10 20 35 35 70
1–18 SW1-010180RN1NF 3 70 2:1 Reflective 10/10 20 35 35 70
SW1-010180AN1NF 3.2 60 2:1 Absorptive 10/10 20 35 35 70
0.8–18 SW1-008180RN1NF 4 70 2:1 Reflective 5 35 40 35 35
0.1–20 SW1-001200RN1NF 5 80 2:1 Reflective 10 35 40 35 35
0.5–2 SW1-005020AN1NF 1.8 75 1.6:1 Absorptive 8 35 40 35 35
0.5–18 SW1-005180RN1NF 3 70 2:1 Reflective 10 35 40 35 70
2–2.2 SW1-020022RN1NF 1 40 1.7:1 Reflective 20 35 40 70 70
2–8 SW1-020080AN1NF 2 55 1.7:1 Absorptive 5 35 40 35 35
3–3.4 SW1-030034AN1NF 1 60 1.5:1 Absorptive 10 35 40 35 70
3–9 SW1-030090RN1NF 1.7 60 1.7:1 Reflective 10 35 40 35 70
3.5–4.5 SW1-035045AN1NF 2 80 1.7:1 Absorptive 20 35 40 60 60
9–9.2 SW1-090092RN1NF 1 70 1.7:1 Reflective 20 35 40 35 70
9.1–9.7 SW1-091097AI2NF 2.6 65 1.7:1 Absorptive 10 30 35 35 70
Electrical performance of multioctave models can be optimized over narrower bandwidths, or for a particular parameter. Electrical options include: Lower
insertion loss, lower VSWR, higher isolation, high power and flat amplitude response. Mechanical/Control options include: Custom packaging, single
supply operation, and ultra-fast on/off time. Consult MITEQ for options.
*For reflective models, VSWR is not specified in the “Off” state. For absorptive models, VSWR in the “Off” state is defined for port J2 only.
OPTIMIZED PERFORMANCE MODELS
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 436-7400 • FAX: (631) 436-7430 • www.miteq.com