DRF/HL Series
120W - 480W Single Output: 24V
180W - 720W Peak Power DIN Rail Mount
Power Supplies for Hazardous Location
DRF/HL Series 1
www.emea.tdk-lambda.com/drfhl
Specications
MODELS DRF120-24-1/HL DRF240-24-1/HL DRF480-24-1/HL
AC Input voltage range VAC 85 - 264 (withstand 300VAC surge for 5s)
Input frequency Hz 47 - 63
Inrush current @ cold start (typ) A 20
Power factor (typ) (115/230) - 0.98/0.95 0.98/0.95 0.98/0.92
Input current (typ) (2) A 1.2/0.6 2.4/1.2 4.7/2.5
Output voltage V 24
Output current A 5 10 20
Peak output current (1) A 7.5 15 30
Peak output power (1) W 180 360 720
Line regulation mV <96
Load regulation mV <240
Ripple and noise (2 & 3) mV <240
Over current protection (4) - > 105% peak output current
Over voltage protection (5) V 30 - 35.5
Hold up time (230VAC) ms 20
Efciency(typ)(230VAC) % 91 94
Averageefciency(230VAC) % 88.6 92.4 92
Standby input power (230VAC) W < 0.5 < 0.5 < 0.75
Parallel operation (6) - Possible
Series operation (6) - Possible
LED indicators -
DC OK signal - green (Vout > 80% rated output voltage): Peak power mode - red
DC OK relay - Relay contact 30V/1A (closed if Vout > 80% of rated output voltage)
Operating temperature °C -25°C to +70°C (60°C to 70°C derate to 75% load)
Storage temperature (7) °C -40°C to +85°C
Operating humidity % 5-95 RH (non condensing)
Operating altitude m Up to 3,000
Cooling - Convection
Withstand voltage - I/P to FG:1.5kVAC (20mA), I/P to O/P 3kVAC (20mA), O/P to FG: 500VAC (100mA) for 1 min
Isolationresistance MΩ I/PtoFG,IPtoO/PandO/PtoFG:>100MOhms(500VDC)at25°C&70%RH
Vibration - Non-operating,10-55Hz(sweep for 1 min.):19.6 m/s2 constant, X,Y,Z axis 1 hour each
Shock - <196m/s2
Safety agency approvals (8) - IEC/EN/UL60950-1, CE, UL508 listed, IECEN60079-0, -15(IECEX, ATEX), DNV-GL
Emissions - EN55022 Class B, CISPR22-B
Immunity - EN61000-4-2,-3,-4,-5,-6,-8,-11
Weight (typ) g 600 900 1300
Size (W x H x D) mm 36.5 x 123.4 x 115.4 49 x 123.4 x 115.4 82 x 123.4 x 115.4
Case material - Metal
Warranty yrs 5
See Page 2 for Notes
,QGXVWULDO 7HVW
Features Benets
•IECEx/ATEXApproval •UseinExplosiveAtmospheres
•DNV/GermanLloydApproval •SuitsMarine,ShipbuildingApplications
•ConformalCoatedCircuitBoards •ResistancetoHarshEnvironment
•NarrowConvectionCooledDesign •SavesSpaceonRail&CabinetCost
•RemoteOn/Off •SupportsIntelligentControls
•ErPReferencedDesign •Improves“EnvironmentalFootprint”