www.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Output Specifications (continued)
Start up time (nominal Vin and constant resistive load) 75 ms typ. (at power On or remote On)
Transient response (25% load step change) 250 µs max.
Output current limitation at 120 -150 % of Iout max.
Over voltage protection at 115 -130 % of Vout nom.
Short circuit protection hiccup, automatic recovery
Capacitive load 12 VDC models: 7‘000 µF max.
24 VDC models: 1‘750 µF max.
28 VDC models: 1‘280 µF max.
48 VDC models: 430 µF max.
General Specifications
Temperature ranges – Operating –40°C to +105°C (up to +85°C w/o derating)
– Storage –40°C to +105°C
Thermal impedance 1.45°C/W
Derating See derating graph below
Over temperature protection at 110°C typ.
Thermal shock acc. MIL-STD-810F
Shock & Vibration acc. EN61373, MIL-STD-810F
Humidity (non condensing) 5 % to 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) > 711‘000 h
Isolation voltage (60sec.) – Input/Output 2’250 VDC (basic insulation)
– Input/Case 1’600 VDC
Isolation resistance – Input/Output (500 VDC) >1 GOhm min.
Switching frequency 24 & 48 Vin models: 250 kHz typ. (puls width modulation)
110 Vin models: 300 kHz typ. (puls width modulation)
Safety standards – CB test certificate IEC/EN 60950-1 (ed. 2), EN 60950-1:2006/
A11:2009/A1:2010/A12:2011/A2:2013
– CSA certificate of compliance UL 508, CSA C22.2 No. 107.1-01
– UL online certification E188913, QQGQ2 UL 60950-1 2nd ed. +Am1
– Railway immunity EN50155
– Certification documents www.tracopower.com/overview/teq100wir
Remote On/Off – positive logic (standard) – On: 3 to 12 VDC or open circuit
– Off: 0 to 1.2 VDC
or short circuit terminal 1 and 4
– negative logic (option -N) – On: 0 to 1.2 VDC
or short circuit terminal 1 and 4
– Off: 3 to 12 VDC or open circuit
– Off idle current: 3 mA
Environmental compliance – Reach document
www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
– Flammability identified acc. EN 45545-2
www.tracopower.com/info/en45545-declaration.pdf
DC/DC Converters
TEQ 100WIR Series 100 Watt
0
20
40
60
80
100
120
-40 -20 0 20 40 60 80 100 120
MBIENT TEMPERATURE,TA(ºC)
OUTPUT POWER(%
Natural convection (20LFM)
Temperature derating