FEATURES
• 30VDCor120VAC,2to40Amps
• Sealedassemblies,availableinmanualandautomaticresetoptions
• Ignitionprotected
• ULRecognizedE36869
DESCRIPTION
The KLIXON® PD series thermal breakers are designed to protect wiring
and meet the harshest environmental requirements. The PD series are
weatherproof sealed for protection against moisture, dust, grease,
fuel vapors and other harsh environments. The PD series breakers
are compact, lightweight and designed to interrupt short circuits or
overloads, and combine trip-free protection with fast response time.
Typical applications are protection of wire and cable of accessory circuits,
equipment and battery protection in construction and off-road equipment,
marine, recreational vehicles (RV’s), mining, agricultural equipment and
electric (hybrid) vehicles.
The PD series is used in commercial and military applications.
ORDERING INFORMATION
Configuration
PDM = Manual, sealed
PDA = Auto, sealed
XXX
Amp Rating
(2, 3, 4, 5, 6, 8, 10, 12.5, 15
17.5, 20, 25, 30, 35, 40)
Mounting Nuts
= leave blank for none
I = include optional mounting nuts
PERFORMANCE CHARACTERISTICS
Calibration :
200% rated current, 77°F (25°C)
2 to 10 amps : 20 to 150 seconds
12.5 to 40 amps : 8 to 50 seconds
Ultimate Trip at 77°F (25°C) Must hold 110%, must trip 138%
Endurance Per SAE J553
Interrupt Current Capacity Per SAE J553 and ABYC E-11
Vibration 10G MIL-STD-202 Method 204, Condition A
Mechanical Shock MIL-STD-202 Method 213, Condition C, 100G
Salt Spray MIL-STD-202 Method 101D
Dielectric Strength MIL-STD-202 Method 301, 1500VAC min
Insulation Resistance MIL-STD-202 Method 302, Condition B,
100 MΩ min
Weight (with mounting nuts) PDM : 48 grams max
PDA : 41 grams max
Small Frame PD Series (PDA, PDM)
2 to 40 Amp Precision Thermal Circuit Breaker
PD Series (PDA/PDM)
19
ROUND HEAD SCREW
2X .250 [6.35] LONG #8-32 UNC-2A
2X (.047 [1.1938]) THK.
LOCKWASHER
.430 [10.92]
.562 [ 14.28]
MIN. PANEL HOLE DIA.
1.145 [29.08]
.380 [9.65]
2.0 [ 50.8]
SEE NOTE 1
1.586 [40.28]
1.562 [39.68]
(DOES NOT INCLUDE SEALING GASKET)
1.221 [31.01]
1.159 [29.44]
3
2
1
R
1
3
2
BOTTOM VIEW
FOR 2 AMP THRU 10 AMP
.312 [7.93]
.641
[16.28]
(45°)
BOTTOM VIEW
FOR 12½ AMP THRU 40 AMP
2X EYELET
FOR #10 SCREW
.906 [23.01]
INCHES [MM]
2X #8-32 UNC-2B
MOUNTING NUTS
FURNISHED WHEN
SPECIFIED
DERATING CURVE
DIMENSIONS - PDM
Performance characteristics are based on room
temperature (77°F, 25°C). Consult Derating curve for ambient
temperatures significantly higher or lower than standard
room temperature.
Example: At 77°F (25°C) the device is calibrated to hold
at 110% of rated current (1) and trip at 138% of rated
current (2). At 140°F (60°C), the same device will hold
at approximately 92% of rated current (3), and trip at
approximately 120% of rated current (4).
60 80 100
Ultimate Trip in % Rated Load
120 140 160 180 200
3 4
1 2
77°F, 25°C
100˚F
140˚F
160˚F
70˚F
-60˚F
-40˚F
0˚F
32˚F
38˚C
60˚C
71˚C
21˚C
-51˚C
-40˚C
-18˚C
0˚C
Ambient Temperature in °F, °C
TRIP CURVE - Approximate Time, Current Characteristics At 77°F (25°C)
Dotted Lines: 10 amps or below
Solid Lines: Above 10 amps
1000
500
100
.10 110
Trip Time in Seconds
Current in % Rated Load
100 1000 10,000
www.sensata.com 20
http://www.sensata.com/
BUSINESS CENTER
Sensata Technologies Inc.
529 Pleasant Street
Attleboro, MA 02703, USA
Phone: +1 508-236-3800
Fax: +1 508-236-2349
©2013 Sensata Technologies, Inc. All rights reserved worldwide. Printed in USA, revised April 2013.
Important Notice: Sensata Technologies reserves the right to make changes to, or to discontinue, any product or service
identified in this publication without notice. Before placing orders, users should obtain the latest version of the relevant
information to verify that the information being relied upon is current.
Sensata Technologies assumes no responsibility for customers’ product designs or applications. Users must determine the
suitability of the Sensata device described in this publication for their application, including the level of reliability required.
Many factors beyond Sensata’s control can affect the use and performance of a Sensata product in a particular application,
including the conditions under which the product is used and the time and environmental conditions in which the product
is expected to perform. As these factors are uniquely within the user’s knowledge and control, it is essential that the user
evaluate the Sensata product to determine whether it is fit for a particular purpose and suitable for the user’s application.
Sensata Technologies products are sold subject to Sensata’s Terms and Conditions of Sale which can be found at:
www.sensata.com/terms.htm