ECE60 Series AC-DC Power Supplies 60 Watts * Ultra Compact Size * Single Outputs from 3.3 to 48 V * Encapsulated * PCB & Chassis Mount Versions * <0.3 W No Load Input Power * Peak Load Capability * 3 Year Warranty Dimensions: ECE60: 3.60 x 1.50 x 1.10" (91.4 x 38.1 x 28.0 mm) ECE60S: 4.09 x 1.57 x 1.12" (104.0 x 40.0 x 28.5 mm) Models & Ratings Output Power Output Current Output Voltage Nominal Peak (1) Efficiency (4) Model Number 400 W 3.3 V 10.00 A 13.00 A 79% ECE60US03 400 W 5.0 V 10.00 A 13.00 A 83% ECE60US05 400 W 9.0 V 6.67 A 8.67 A 87% ECE60US09 400 W 12.0 V 5.00 A 6.50 A 87% ECE60US12 400 W 15.0 V 4.00 A 5.20 A 88% ECE60US15 400 W 24.0 V 2.50 A 3.25 A 89% ECE60US24 400 W 36.0 V 1.67 A 2.17 A 88% ECE60US36 400 W 48.0 V 1.25 A 1.63 A 86% ECE60US48 Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal power. 2. Add suffix -S to model number to denote chassis mount with screw terminal type, e.g. ECE60US12-S. Only available with ECE40 models. 3. A screw terminal versions (-S) is available with DIN Clip attached. Add suffix `D', e.g. ECE60US24-SD. DIN Rail mounting clip is available as a separate item, order code ECL25/30 DIN CLIP. 4. Average of efficiencies measured at 25%, 50%, 75% & 100% load with 230 VAC input. 5. 3.3 & 5 V ECE60-S versions meet 75 mV pk-pk with 20 MHz bandwidth and 0.1 F capacitor across output terminals. Summary Characteristic Input Range Minimum Maximum Units 85 264 VAC 120 370 VDC No Load Input Power Efficiency Operating Temperature 1 Typical Notes & Conditions Derate load from 100% at 90 VAC to 90% at 85 VAC <0.3 W 12-36 V versions <0.5 W 3.3-9 V & 48 V versions 79 89 % -25 +70 C EMC EN55022 Level B Conducted & Radiated, EN61000-4, EN61000-3 Safety Approvals EN60950-1, UL60950-1, CSA22.2 No. 234 per cUL www.xppower.com Derate linearly from 100% at +50 C to 50% at +70 C (2,3) ECE60 Series AC-DC Power Supplies Input Characteristic Input Voltage - Operating Input Frequency Minimum Maximum Units 85 Typical 264 VAC 120 370 VDC 63 Hz 47 Notes & Conditions Derate load from 100% at 90 VAC to 90% at 85 VAC Power Factor >0.95 Input Current 0.3 A rms <0.3 W <0.5 W 3.3-9 V & 48 V versions 20/40 A 115/230 VAC cold start at 25 C No Load Input Power Inrush Current EN61000-3-2 class A compliant Earth Leakage Current Input Protection At 230 VAC 12-36 V versions Class II construction no earth Internal T1 A/250 VAC fuse Output Characteristic Output Voltage - V1 Minimum Typical 3.3 Initial Set Accuracy Minimum Load Maximum Units Notes & Conditions 48 VDC See Models and Ratings table 1 (V1) % 0 A Start Up Delay 2 s Start Up Rise Time 16 ms Hold Up Time 18 ms Line Regulation % 2 % 1 % All other models 4 % Recovery within 1% in less than 500 s for a 25% load change 60 mV pk-pk 3.3-5 V versions, 20 MHz bandwidth 75 mV pk-pk 3.3-5 V `-S' versions, 20 MHz bandwidth (see note 5) 1 % pk-pk 20 MHz bandwidth 216 % Vnom ECE60US03 model 115 140 % Vnom All other models 110 180 % 0.05 %/C Maximum Units 89 % Load Regulation Transient Response Ripple & Noise Overvoltage Protection Overload Protection At full load and 115 VAC 0.5 195 Short Circuit Protection ECE60US03/05-S Trip & restart (hiccup mode) Temperature Coefficient General Characteristic Minimum Efficiency 79 Isolation 3000 Typical VAC 70 Switching Frequency Power Density Notes & Conditions See Models & Ratings table Input to Output kHz 10.1 W/in3 Mean Time Between Failure >300 kHrs Weight TBA lb (kg) MIL-HDBK-217F, +25 C GB Environmental Characteristic Maximum Units Operating Temperature Minimum -25 Typical +70 C Storage Temperature -40 +85 C 95 %RH 3048 m Cooling Humidity Operating Altitude Vibration Notes & Conditions Derate linearly from 100% at +50 C to 50% at +70 C Convection-cooled Non-condensing 2 g, 10 Hz to 500 Hz, 10 mins/cycle, 60 mins each cycle www.xppower.com 2 ECE60 Series AC-DC Power Supplies EMC: Emissions Phenomenon Standard Test Level Criteria Notes & Conditions Test Level Criteria Notes & Conditions A Conducted EN55022 Class B Radiated EN55022 Class B EMC: Immunity Phenomenon Standard Harmonic Current EN61000-3-2 / -3-3 ESD EN61000-4-2 3 Radiated EN61000-4-3 10 V/m 80% mod A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Dips and Interruptions EN61000-4-11 DIP: 100% 10 ms DIP: 30% 500 ms INT: 100% 5000 ms A A B Safety Approvals Safety Agency Safety Standard UL UL60950-1, CSA 22.2 No.234 per cUL Notes & Conditions TUV EN60950-1 Mechanical Details ECE60 ECE60 Screw Terminal (S) 3.60 (91.4) 0.50 (12.7) 0.13 (3.2) ACL 1.50 (38.1) 1.18 (30.0) 0.18 (4.5) 4x o0.14 (4x o3.5) 0.44 (11.2) +Vo TOP VIEW 4.09 (104.0) ACN -Vo 1.57 (40.0) 0.14 (3.5) TOP VIEW ACL -Vo 0.84 (21.3) 1.20 +Vo (30.5) ACN 3.50 (89.7) 3.32 (84.3) 0.19 (4.8) 0.54 (13.8) 1 1.12 (28.5) 1.10 (28.0) 4x o 0.06 (o1.5) 0.24 (6.2) 0.39 (10.0) 0.10 (2.5) 3.78 (96.0) Optional DIN clip Notes 1. All dimensions in inches (mm). 2. Weight: ECE60: 0.?? lbs (??? g) ECE60-S: 0.?? lbs (170 g) 3. Tolerances: x.xx = 0.02 (x.x = 0.5), x.xxx = 0.01 (x.xx = 0.25) 3 www.xppower.com 10Mar14