NUMBER
GS-12-625 TYPE Product Specification
TITLE PAGE REVISION
Terminal block- Plug and Socket, Fixed Plug 4 of 8 D
AUTHORIZED BY DATE
Jason Hsu Nov. 11
, 2009
CLASSIFICATION Unrestricted
This document is the property of and embodies CONFIDENTIAL and PROPRIETARY information of FCI. No part of the information shown on the document may be used in any way or
disclosed to others without the written consent of FCI. Copyright FCI.
Form E-3005
Rev F
GS-01-001
3.5.1.5
Temperature rise
VS current
UL 1059
Measurements are made when the specimen had reached
thermal equilibrium at the rated current specified on
individual drawing.
+30 ℃ Maximum
3.5.2
MECHANICAL REQUIREMENTS
DESCRIPTION TEST CONDITION REQUIREMENT Applicable
3.5.2.1
Mating force Mate connector and measure the force
required. 5.5N Maximum.
(Per mating pole.)
Plug/socket
3.5.2.2
Unmating force Unmate connector and measure the force
required. 1.0N Minimum.
(Per unmating pole.) Plug/socket
3.5.2.3
Durability
(mate/unmate)
After durability cycles, low level contact
resistance shall be less than 20millionohm. 200 Cycles
Plug/socket
3.5.2.4
Wire Pull Strength
IEC 60998-2-1 paragraph 10.105,
Subject connector to a pull force for 1 minute
in the axis of tapping connector.
Connector shall not slip out of the connecting
device.
10AWG: Min 80N
12AWG: Min 60N
16AWG: Min 30N
24AWG: Min 13N
Plug/Fixed
plug
3.5.2.5
Torque UL1059
Apply the rated torque (refer to drawings) for
wire attachment.
No visible crack Plug/Fixed
Plug
3.5.2.6
Pin Retention Force required to unload pin from the housing
in the direction of plug entry. Min 20N. Socket
3.5.2.7
Solder ability Soldering time 5 second. (flux is applied)
Soldering temperature: 250±10℃ 95% min of solder area and
the plastics have not been
melted
Fixed
plug/Socket
3.5.3
ENVIRONMENT REQUIREMENTS
DESCRIPTION TEST CONDITION REQUIREMENT
3.5.3.1
Heat Resistance IEC 60998-2-1, paragraph 12.1
Subject specimens to 115±2℃ for 168 hours and shall be
left alone for 1 to 2 hours in a room ambient for next
examination/testing.
No cracks visible.
No material becomes sticky.
No material becomes greasy.
Specimen shall not undergo
any change impairing their
further use.
3.5.3.2
Cold resistance IEC 60998-2-1, paragraph 12.1
Subject specimens to -40±2℃ for 168 hours and shall be
left alone for 1 to 2 hours in a room ambient for next
examination/testing..
3.5.3.3
Humidity IEC 60998-1, paragraph 12.2.
Subject specimens to 30±2℃, relative humidity 91%~95%
for 48 hours and shall be left alone for 1 to 2 hours in a
room ambient for next examination/testing...
3.5.3.4
Salt Spray EIA-364-26B, condition A
Salt concentration: 5%, temperature 32±2℃, 48hours.
PDS: Rev :E STATUS:Released Printed: Mar 05, 2012