RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance. DS1000E series are designed with dual channels and 1 external trigger channel. DS1000D series are designed with dual channels and 1 external trigger channel as well as 16 channels logic analyzer. Applications Easy to Use Design Electronic Circuit Test Circuit Functional Test Logical Relation Between Singals Verification Circuit of Mixed Signal Test Education & Training Main Features Dual analog channels and 16 channels logic analyzer, 100MHz maximum bandwidth, 1GSa/s maximum real-time sample rate and 25GSa/s maximum equivalent sample rate 5.6 inch 64k TFT LCD makes the waveform displays more clear and vivid Abundant trigger types: Edge, Pulse Width, Video, Slope, Alternate, Pattern and Duration Unique adjustable trigger sensitivity enables to meet different demands Enable to measure 22 types of wave parameters and track measurements via cursor automatically Unique waveform record and replay Built-in help menu enables information acquisition more convenient Multiple language menu and Chinese & English input Can store files in USB storage device or local the internal memory Analog waveform intensity can be adjusted To display a signal automatically by AUTO Pop-up menu makes it easy to read and use function Fine delayed scan function Built-in FFT function, hold practical digital filters Pass/Fail detection function enables to output testing results Multiple math operations for waveforms Powerful PC application software UltraScope Standard configuration interface: USB Device, USB Host , RS-232 and support USB storage device storage and PictBridge print standards The new function "Key Lock" can meet the needs of industrial production Support for remote command control Dec. 2015 RIGOL TECHNOLOGIES, INC. Automatically Measure 22 Waveform Parameters Cursor Measure DS1000E, DS1000D series oscilloscopes can measure 20 types of waveform parameters automatically, which contains 10 voltage and 12 time parameters. Automatic measure Multiple Trigger Pattern trigger In cursor mode, users can easily measure by moving cursor. 3 types of cursor measurement are optional: Manual, Track and Auto. FFT cursor measure Both DS1000E and DS1000D series contain abundant triggers: Edge trigger, Pulse Width trigger, Video trigger, Slope trigger Alternate trigger, Pattern trigger (DS1000D), Duration trigger (DS1000D) Especially the duration trigger is a new type from perfect combination of patten and pulse width trigger. Unique function of adjustable trigger sensitivity is good for filtering possible noise from signal in order to avoid false triggers. 16 Channels Logic Analyzer Being equipped with 16 channels logic analyzer, DS1000D series mixed signal oscilloscopes achieve mixed signal measure coordinating with 2 analog channels. Each channel can be turned on or off independently, or in groups of 8(D7-D0 and D15-D8); also, you can set waveform size and threshold types or change the display position on screen for digital channel. Digital channels setup Waveform Recording In virtue of waveform recording function from DS1000E and DS1000D, not only the outputs from two channels could be recorded, but also the waveforms outputted by Pass/Fail test could be easily recorded. Totally, up to 1000 frames of wavefoms can be recorded. Besides, users can playback and save the waveforms to get better waveform analyzing result. Waveform recording Pass/Fail Testing The Pass/Fail function monitors the changes of signals by comparing whether the input signal is within the pre-defined mask. The testing results not only can be displayed on screen or output by isolated pass/fail port, but also can be alarmed according to turn on system sound. UltraScope Software Measurement window Pass/Fail testing RIGOL provides powerful PC application software, UltraScope, which enables to capture and measure waveforms, to perform local or remote operation, to save waves as ".bmp" format, to save files as ".txt" or ".xls" format as well as to print waveforms. Key Lock This function is widely used in productions. All keys are locked except F1 to F5 and MENU ON/OFF in this mode. To lock the keyboard, use menu; to unlock, correct password has to be input. Also, you can reset a new password if necessary. Key Lock function 1 Specifications All specifications apply to DS1000E, DS1000D Series Oscilloscopes unless otherwise noted. To come up to these specifications, two conditions must be met firstly: The instrument must have been operated continuously for 30 minutes under the specified operating temperature. Do perform Self-Calibration operation through the Utility menu if the range of operating temperature variations up to or more than 5C. NOTE: All specifications are guaranteed unless where marked "typical". Specifications Bandwidth DS1102E 100MHz Acquisition Sample Modes Sample Rate Averages Inputs Input Coupling Input Impedance Probe Attenuation Factors Maximum Input Voltage Time Delay between Channels (typical) Horizontal Sample Rate Range Waveform Interpolation Memory Depth Scanning Speed Range (Sec/div) Sample Rate and Delay Time Accuracy Vertical DS1052E 50MHz DS1102D 100MHz DS1052D 50MHz Real-Time Sample Equivalent Sample DS1102X DS1052X 1GSa/s[1], 500MSa/s 25GSa/s 10GSa/s The waveform will be displayed one time when all the channels finish N times sample. Wherein, N could be selectable from 2, 4, 8, 16, 32, 64, 128 and 256. DC, AC, GND 1M2%, the input capacity is 18pF3pF 1X, 5X, 10X, 50X, 100X, 500X,1000X 400V (DCAC Peak, 1M input impedance) 40V (DC+AC Peak) [2] 500ps Real-Time: 13.65Sa/s-1GSa/s Equivalent: 13.65Sa/s-25GSa/s Sin(x)/x Channel Memory Depth Sample rate Mode (normal) Single 1GSa/s 16kpts channel Single 500MSa/s 16kpts channel or lower Dual 500MSa/s 8kpts channel or lower Dual 250MSa/s 8kpts channel or lower 2ns/div~50s/div, DS1102X 5ns/div~50s/div, DS1052X 1-2-5 Sequence Memory Depth (long memory) N.A. 1Mpts N.A. 512kpts 50ppm (any interval 1ms) 2 A/D Converter Volts/div Range Maximum Input Offset Range Analog Bandwidth Single-shot Bandwidth Selectable Analog Bandwidth Limit (typical) Lower Frequency Response (AC, -3dB) Rise Time (typical at BNC, equivalent sample) DC Gain Accuracy DC Measurement Accuracy (Average Acquisition Mode) Delta Volts Measurement Accuracy (Average Acquisition Mode) Trigger Trigger Sensitivity Trigger Level Range Trigger Level Accuracy (typical) applicable for the signal of rising and falling time 20ns Trigger Offset 8-bit resolution, all channels sample simultaneously 2mV/div~10V/div (at the input terminal connecting to BNC) Maximum input voltage on analog channel CAT I 300Vrms, 1000Vpk; instantaneous overvoltage 1000Vpk CAT II 100Vrms, 1000Vpk RP2200 10:1CAT II 300Vrms RP3300A 10:1CAT II 300Vrms 40V (250mV/div~10V/div) 2V (2mV/div~245mV/div) 100MHz (DS1102D, DS1102E) 50MHz (DS1052D, DS1052E) 100MHz (DS1102D, DS1102E) 50MHz (DS1052D, DS1052E) 20MHz 5Hz (at input BNC) <3.5ns, <7ns, respectively at 100MHz, 50MHz 2mV/div-5mV/div: 4% (In Normal or Average acquisition mode) 10mV/div-10V/div: 3% (In Normal or Average acquisition mode) When vertical position is zero and N 16: (DC Gain Accuracyxreading+0.1div+1mV) When vertical position is not zero and N 16: [DC Gain Accuracyx(reading+vertical position)+(1% of vertical position) + 0.2div] When vertical scale is between 2mV/div and 245mV/div, add 2mV more for setting value. When vertical scale is between 250mV/div and 10V/div, add 50mV more for setting value. U nder sam e setting and condition, the voltage difference (V) between any two points in the waveforms coming from the average of more than 16 waves have been acquired: (DC Gain Accuracyxreading + 0.05 div) 0.1div~1.0div (adjustable) Internal 6 div from center of screen EXT 1.2V Internal (0.3div x V/div) (4 divisions from center of screen) EXT (6% of setting + 200 mV) In Normal mode: pre-trigger (memory depth/ 2*Sample rate), delayed trigger 1s In Slow Scan mode: pre-trigger 6div, delayed trigger 6div Trigger Holdoff Range 500ns~1.5s Set Level to 50% (typical) When input signal frequency 50Hz Edge Trigger Edge trigger slope Pulse WidthTrigger Trigger Condition Pulse Width Range Rising, Falling, Rising + Falling (, , =) Positive pulse width, (, , =) Negative pulse width 20ns ~10s 3 Video Trigger Video Standard Line Frequency Slope Trigger Trigger Condition Time Setting Alternate Trigger Trigger on CH1 Trigger on CH2 Pattern Trigger[2] Pattern Type Duration Trigger[2] Pattern Type Qualifier Time Setting Measurements Cursor Auto Measure Support for standard NTSC, PAL and SECAM broadcast systems. Line number range: 1~525 (NTSC) and 1~625 (PAL/SECAM) (, , =) Positive slope, (, , =) Negative slope 20ns~10s Edge, Pulse Width, Video, Slope Edge, Pulse Width, Video, Slope D0~D15 select H, L, X, , D0~D15 select H, L, X , , = 20ns~10s Voltage difference between cursors (V) Manual Time difference between cursors (T) Reciprocal of T in Hertz (1/T) Track Voltage value and time value of waveform point Auto Cursors are visible for Automatic Measurement Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay12 , Delay12 Remarks: [1] Only one channel is available when the Sample rate is 1GSa/s. [2] For DS1000D Series. 4 General Specifications Display Display Type Display Resolution Display Color Display Contrast (typical) Backlight Brightness (typical) Probe Compensator Output Output Voltage (typical) Frequency (typical) Power Supply Supply Voltage Power Consumption Fuse Environmental Ambient Temperature Cooling Method Humidity Altitude 145mm (5.6 inch) diagonal TFT Liquid Crystal Display 320 horizontal xRGBx234 vertical pixels 64k color 150:1 300 nit Approximately 3Vpp (peak to peak value) 1kHz 100 ~ 240VACRMS, 45~440Hz, CAT II Less than 50W 2A, T level, 250 V Operating 10~ 40 Non-operating -20~ +60 fan cooling below +35: 90% relative humidity +35~ +40: 60% relative humidity Operating at 3,000 m or below Non-operating at 15,000 m or below Mechanical Dimensions Weight Width Height Depth Without package Packaged 303mm 154mm 133mm 2.3kg 3.5kg IP Protection IP2X Calibration Interval The recommended calibration interval is one year 5 Ordering Information Warranty Name of Product Thank you for choosing RIGOL products! RIGOL DS1000E, DS1000D series oscilloscopes RIGOL warrants that the product mainframe and product accessories will be free from defects in materials and workmanship within the warranty period. Standard Accessories Probex2 (1.5m), (1:1 or 10:1 adjustable) Passive Probes A Power Cord that fits the standard of destination country A Data Cable (DS1000D series) An Active Logic Head (DS1000D series) 20 Logic Testing Nips (DS1000D series) 20 Logic Testing leads (DS1000D series) A Quick Guide Optional Accessories BNC Cable USB Data Cable RS232 Cable USB-GPIB Adapter DS1000E, DS1000D soft carrying case If a product proves defective within the respective period, RIGOL guarantees free replacement or repair of any defective products within a reasonable period of time. To get repair service, please contact with your nearest RIGOL sales or service office. There is no other warranty, expressed or implied, except such as is expressly set forth herein or other applicable warranty card. There is no implied warranty of merchantability or fitness for a particular purpose. Under no circumstances shall RIGOL be liable for any consequential, indirect, ensuing or special damages for any breach of warranty in any case. Contact Us If you have any problem or requirement when using our products or this manual, please contact RIGOL. E-mail: service@rigol.com Website: www.rigol.com 6