DC-DC Converters
50 to 200 Watts
VI-200
VE-200
VI-200 DC-DC Converters Rev 3.9
Page 1 of 7 08/2017
S
NRTL
CUS
CUS
®
Features & Benefits
Isolated output
Up to 50W/in3
cURus, cTÜVus
Up to 90% efficiency
Size: 4.6” x 2.4” x 0.5”
(116,8 x 61,0 x 12,7mm)
Remote sense and current limit
OVP, thermal shutdown
Logic disable
Wide range output adjust
Compatible power booster modules
ZCS power architecture
Low noise FM control
CE Marked
RoHS compliant (VE-200)
Product Highlights
The VI-200 family, with over 14 million units shipped, is Vicor’s broad series of
zero-current-switching” component-level DC-DC converters.
Operating at frequencies up to 2MHz, VI-200 family converters offer exceptional power
density, efficiency, noise performance, reliability and ease of use. Booster modules
(VI-Bxx) provide a simple, cost-effective, off-the-shelf solution for higher power output
requirements. One or more boosters may be used to create synchronous arrays capable
of supplying several kilowatts of output power.
The flexibility of Vicor’s power components is also available in half-size, half-power
VI-J00 MiniMods.
Part Numbering
Note: For additional
packaging options,
please see page 5.
VI 2 6 1 C W
Family Series Input Output Grade Power
VI = Non-RoHS 2 = 200 0 = 12V N = 48V Z = 2V M = 10V K = 40V E = –10 to 85°C ≥ 5V < 5V
VE = RoHS B = Booster V = 24V 4 = 72V Y = 3.3V 1 = 12V 4 = 48V C = –25 to 85°C U = 200W U = 40A
1 = 24V T = 110V 0 = 5V P = 13.8V H = 52V I = 40 to 85°C V = 150W V = 30A
W = 24V 5 = 150V X = 5.2V 2 = 15V F = 72V M = –55 to 85°C W = 100W W = 20A
2 = 36V 6 = 300 V W = 5.5V N = 18.5V D = 85V X = 75W X = 15A
3 = 48V 7 = 150/300V V = 5.8V 3 = 24V B = 95V Y = 50W Y = 10A
T = 6.5V L = 28V
R = 7.5V J = 36V
VI-200 DC-DC Converters Rev 3.9
Page 2 of 7 08/2017
VI-200, VE-200
Converter Specifications
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
Input Specifications
Maximum Power Available for VI-2xx-xx [a]
Input Output
Voltage
Nom. (Range)
Low
Line
75%
Max
Power
Transient [b]
VIN
Designators
VOUT Designators
2
3.3
5
5.2
5.5
5.8
6.5
7.5
10
12
13.8
15
18.5
24
28
36
40
48
52
72
85
95
Z Y 0 X W V T R M 1 P 2 N 3 L J K 4 H F D B
12 (10 – 20) n/a 22 0XXXXXXXXXXXXXXXXXXXXXX
24 (10 – 36) n/a n/a V-- X Y Y Y Y Y X X X X X X X X X X X -- -- -- --
24 (21 – 32) 18 36 1UUUUUUVVUUUUUUUUUUUUUU
24 (18 – 36) n/a n/a WVVVVVVWWVVVVVVVVVVVVVV
36 (21 – 56) 18 60 2W V WWWWWWWWWWWWWWWWW-- -- --
48 (42 – 60) 36 72 3UUUUUUUUUUUUUUUUUUUUUU
48 (36 – 76) n/a n/a NUUUUUUUUUUUUUUUUUUUUUU
72 (55 – 100) 45 110 4vUUUUUVVUUUUUUUUUUUUUU
110 (66 – 160) n/a n/a TVVVVVVWWVVVVVVVVVVVV----
150 (100 – 200) 85 [c] 215 5U U V V V V V V U U U U U U U U U U U U U U
150 (100 – 375) n/a n/a 7WW Y Y Y Y WWWWWWWWWWWWW -- -- --
300 (200 – 400) 170 [d] 425 6UUUUUUVVUUUUUUUUUUUUUU
[a] For additional output power, “booster” modules are available. (VI-Bxx-xx).
[b] Transient voltage for 1 second.
[c] 12VOUT, 13.8VOUT, 15VOUT, 200W models are limited to 90VDC.
[d] 15VOUT, 200W models are limited to 185VDC.
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test
Conditions
Inrush charge 120 x 10-6 120 x 10-6 200 x 10-6 Coulombs Nominal line
Input reflected
ripple current – pp 10% 10% IIN
Nominal line,
full load
Input ripple
rejection
25+20 Log 30+20 Log dB 120Hz,
nominal line
20+20 Log dB 2400Hz,
nominal line
No load power
dissipation 1.35 2 1.35 2 Watts
VIN
VOUT
( ) VIN
VOUT
( )
VIN
VOUT
( )
VI-200 DC-DC Converters Rev 3.9
Page 3 of 7 08/2017
VI-200, VE-200
Converter Specifications (Cont.)
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)
[a] 10V to 15V outputs, or “V” input range have standard trim range ±10%. Consult factory for wider trim range.
3.3V output trim range 2.20 to 3.63V, 95V output –50 + 0% trim range.
[b] 131% nominal for booster modules.
[c] Output voltages of 3.3V or 5V incorporate foldback current limiting; For output voltages from 5.2V to 7.5V consult factory;
All other outputs provide constant current limiting.
Output Characteristics
Control Pin Specifications
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test
Conditions
Setpoint accuracy 1% 2% 0.5% 1% VNOM
Load/line
regulation 0.5% 0.05% 0.2% VNOM
LL to HL, 10%
to Full Load
Load/line
regulation 1% 0.2% 0.5% VNOM
LL to HL, No
Load to 10%
Output
temperature drift 0.02 0.01 0.02 % / °C Over rated
temp.
Long term drift 0.02 0.02 %/1K hours
Output ripple – pp:
150 60 100 mV
20MHz
bandwidth
2V, 3.3V
5V 5% 2% 3% VNOM
20MHz
bandwidth
10 – 95V 3% 0.75% 1.5% VNOM
20MHz
bandwidth
Trim range [a] 50% 110% 50% 110% VNOM
Total
remote sense
compensation
0.5 0.5 Volts 0.25V max.
neg. leg
OVP set point 125% [b] 115% 125% [b] 135% VNOM Recycle power
Current limit 105% 135% 105% 125% IFULL LOAD
Automatic
restart
Short circuit
current [c] 20% 140% 20% 130% IFULL LOAD
Automatic
restart
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test
Conditions
Gate out
impedance 50 50 Ohms
Gate in impedance 1000 1000 Ohms
Gate in open
circuit voltage 6 6 Volts Use open
collector
Gate in low
threshold 0.65 0.65 Volts
Gate in low
current 6 6 mA
Power sharing
accuracy 0.95 1.05 0.95 1.05
Note: The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application information,
please refer to output connections on page 5.
VI-200 DC-DC Converters Rev 3.9
Page 4 of 7 08/2017
VI-200, VE-200
Dielectric Withstand Characteristics
Thermal Characteristics
Mechanical Specifications
Product Grade Temperatures
Maximum Capacitance, Rated Output Voltage <5V
Maximum Capacitance, Rated Output Voltage 5V
[d] No overtemp protection in booster modules.
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test
Conditions
Input to output 3,000 3,000 VRMS
Baseplate
earthed
Output to
baseplate 500 500 VRMS
Input to baseplate 1,500 1,500 VRMS
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test
Conditions
Efficiency 78 – 88% 80 – 90%
Baseplate to sink
thermal impedance 0.07 0.07 °C/Watt With Vicor
P/N 20266
Thermal
shutdown [d]
(Drivers only)
90 95 105 90 95 105 °C
Cool and
recycle power
to restart
VI-200 E-Grade VI-200 C-, I-, M-Grade
Parameter Min Typ Max Min Typ Max Units Test
Conditions
Weight 5.7
(160.2)
6.3
(178)
6.9
(195.8)
6.6
(187.2)
7.3
(208)
8.1
(228.8)
Ounces
(Grams)
Parameter Storage Operating Units Notes
E-20 to +100 -10 to + 85 °C
Overtemperature shutdown
95°C typical (recycle power
to restart)
C-40 to +100 -25 to + 85 °C
I-55 to +100 -40 to + 85 °C
M-65 to +100 -55 to + 85 °C
Rated VOUT (V) IOUT Rating (A) CMAX (µF) IOUT Rating (A) CMAX (µF)
2 to <3 10 1500 >10 to 40 5000
3 to <5 10 1000 >10 to 40 5000
Rated VOUT (V) POUT Rating (W) CMAX (µF) POUT Rating (W) CMAX (µF)
5 to <7.5 50 1000 >50 to 200 1500
7.5 to <10 50 400 >50 to 200 700
10 to <28 50 400 >50 to 200 500
>28 50 150 >50 to 200 250
Converter Specifications (Cont.)
(Typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified.)