853 FIBER SENSORS Leak Detection Sensor Amplifier Built-in EX-F70 SERIES EX-F60 SERIES Related Information General terms and conditions............ F-17 General precautions...................... P.1405 Sensor selection guide.................. P.831~ Korea's S-mark.............................. P.1410 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive MICRO PHOTOELECTRIC SENSORS AREA SENSORS Recognition Certified (Excluding PNP output type) LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic-electric-works.net/sunx STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS High-speed detection even a little liquid leak EX-F70 SERIES Reliable detection The unique effect of capillarity enables reliable detection of small leaks and viscous liquids. No need for sensitivity adjustment Capillarity effect Sensor body Liquid Easy operation check Leakage pan New type of detection method When a leak occurs, the beam from the beam-emitting part scatters through the leaked liquid and is not transmitted to the beam-receiving part. Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 Beam-emitting part Beam-receiving part Beam-emitting part Beam-receiving part Sensing surface Sensing surface The beam from the beam-emitting part scatters through the leaked liquid and is not transmitted to the beam-receiving part. The beam from the beam-emitting part reflects off of the surface of the sensor and is transmitted to the beam-receiving part. Leaked liquid Leakage pan Leakage pan Compact, space-saving This slim (10 mm 0.394 in) side-mounting sensor is especially good for use in confined spaces. No need for sensitivity adjustment with adjuster, so initial mounting is easy. 10 mm 0.394 in approx. This sensor is equipped with a NORMAL indicator (green) which lights up when mounting correctly, and a FAULT indicator (red) which lights up when sensing the leaked liquid or when mounted incorrectly (forgetting to mount exclusive mounting bracket). So, the operation can be checked easily. Safe design If the sensor is not mounted correctly, if the cable is broken or disconnected, or if the sensor is not operating correctly, the output is the same as when the beam is not received (LEAK). Design deals with human errors such as, forgetting to mount, etc. Easy installation & reset Facilitates easy installation: the SUS mounting bracket type can be installed using only a single screw and the PVC mounting bracket type can be installed using only two screws or an adhesive. No component replacement required for resetting after leak detection. The simple shape makes it easy to wipe off the leaked liquid. PVC mounting bracket available SUS mounting bracket type EX-F71 PVC mounting bracket type EX-F72 EX-F72 A mounting bracket made of PVC (polyvinyl chloride) is available. This mounting bracket can be used normally in environments that would corrode normal metal brackets. Leak Detection Sensor EX-F70 SERIES EX-F60 SERIES EX-F60 SERIES FIBER SENSORS PFA enclosure gives excellent chemical resistance Compact, space-saving The sensor enclosure and the cable sheath are made from PFA which is highly resistant to chemicals. Accurate sensing is achieved even if there are leaks of chemicals such as sulfuric acid, hydrochloric acid or ammonia. Even with its built-in amplifier, the size is compact at W26 x H19 x D9 mm W1.024 x H0.748 x D0.354 in, so that it can be used even in narrow spaces. PFA coating PFA case Easy installation & reset LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS 26 mm 1.024 in The simplified shape makes it easy to clean up after liquid leaks, simply by wiping off the liquid, and no parts need to be replaced. 9 mm 0.354 in 19 mm 0.748 in EX-FC1 is a simple wire-saving unit for exclusive use with EX-F71/F72, EX-F61/F62 leak detection sensors. (It can be used with general sensors as well.) EX-FC1 integrates the outputs from up to 8 leak detection sensors into a single OR output, so significant wiring and space savings are achieved. * Even with only one leak detection sensor connected, an OFF signal is output if the sensor detects liquid leakage, or if the unit has been installed incorrectly. SENSOR OPTIONS Slim & compact Space savings are significant, as the ultra-thin & compact EX-FC1 has main unit body dimensions of only W20 x H80 x D52 mm W0.787 x H3.150 x D2.047 in. Connects easily with one-touch connector Connections are made by simply inserting the leak detection sensor cable leads into the snap male connector SL-CP1, then push until the connector snap-locks! This saves the time and the trouble of stripping the insulation from each lead before attaching to terminals. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Leak detection sensors General purpose SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES ORDER GUIDE Chemical-resistant PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS Wire-saving unit made especially for connecting leak detection sensors! Saves wiring! Now connects up to 8 leak detection sensors LIGHT CURTAINS INDUCTIVE PROXIMITY SENSORS EX-FC1 Type 854 FA COMPONENTS Appearance Sensing object Cable length SUS mounting bracket type Water, FluorinertTM (Note 1, 2) PVC mounting bracket type Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note 1, 3) Notes: 1) Highly viscous liquid may not be detected stably. 2) FluorinertTM is the world wide trademark of 3M. 3) The agents mentioned above are examples. For details, please contact our office. Output EX-F71-PN PNP open-collector transistor EX-F72 NPN open-collector transistor Selection Guide EX-F72-PN PNP open-collector transistor Liquid Leak Detection EX-F61 NPN open-collector transistor EX-F61-PN PNP open-collector transistor EX-F62 NPN open-collector transistor EX-F62-PN PNP open-collector transistor Simple wire-saving unit for leak detection sensor Model No. Output EX-FC1 Relay contact 1 a 5 m 16.404 ft cable length type 5 m 16.404 ft cable length type (standard: 2 m 6.562 ft or 3 m 9.843 ft) is also available. When ordering this type, suffix "-C5" to the model No. (e.g.) 5 m 16.404 ft cable length type of EX-F71-PN is "EX-F71-PN-C5". UV CURING SYSTEMS NPN open-collector transistor 3 m 9.843 ft Appearance MACHINE VISION SYSTEMS EX-F71 2 m 6.562 ft PVC mounting bracket type PFA mounting bracket type Model No. Wafer Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 855 FIBER SENSORS Leak Detection Sensor EX-F70 SERIES EX-F60 SERIES OPTIONS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS Unit mounting bracket Designation Model No. Description Unit mounting bracket MS-DIN-3 Mounting bracket for EX-FC1 * MS-DIN-3 Accessories * MS-EX-F7-1 * MS-EX-F7-2 * MS-EX-F6-1 SUS mounting PVC mounting bracket PFA mounting bracket for adhesive fixing bracket * MS-EX-F6-2 PVC mounting bracket * SL-CP1 * SC-PK (Snap male connector) (Connector end caps) 10 pcs. per set * MS-SL-2 Unit mounting base 8 pcs. per set PRESSURE / FLOW SENSORS Connector end caps SC-PK INDUCTIVE PROXIMITY SENSORS * MS-EX-F7-3 PVC mounting bracket for two-point fixing PARTICULAR USE SENSORS 1 2 3 4 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS SPECIFICATIONS Sensors STATIC CONTROL DEVICES Model No. Type ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 Item General purpose Chemical-resistant SUS mounting bracket type PVC mounting bracket type PFA mounting bracket type PVC mounting bracket type NPN output EX-F71 EX-F72 PNP output EX-F71-PN EX-F72-PN Sensing object Current consumption EX-F62-PN 12 to 24 V DC 10 % Ripple P-P 10 % or less 15 mA or less * Maximum sink current: 50 mA * Applied voltage: 30 V DC or less (between output and 0 V) * Residual voltage: 1.0 V or less (at 50 mA sink current) 0.4 V or less (at 16 mA sink current) Utilization category Output operation EX-F61-PN 10 mA or less (PNP output type: 15 mA or less) NPN open-collector transistor Output EX-F62 Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note 2, 4, 6) Water, FluorinertTM (Note 2, 3) Supply voltage EX-F61 PNP open-collector transistor * Maximum source current: 50 mA * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 1.0 V or less (at 50 mA source current) 0.4 V or less (at 16 mA source current) DC-12 or DC-13 In normal state: ON, When leak detected or the sensor is mounted improperly: OFF Short-circuit protection Incorporated Response time 50 ms or less FAULT indicator Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) NORMAL indicator Green LED (lights up when the sensor is mounted properly) Pollution degree 3 (Industrial environment) Protection Ambient temperature IP67 (IEC) -10 to +60 C +14 to +140 F (No dew condensation or icing allowed), Storage: -20 to +70 C - 4 to +158 F (Note 5) Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 1,000 x at the light-receiving face Emitting element Material Cable Cable extension Weight Accessories Infrared LED (non-modulated) Enclosure: Polypropylene Enclosure: PFA 0.1 mm2 3-core PVC cabtyre cable, 2 m 6.562 ft long 0.1 mm2 3-core PFA cabtyre cable, 3 m 9.843 ft long Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable. Net weight: 25 g approx. MS-EX-F7-1 (SUS mounting bracket) (Note 7): 1 pc. Net weight: 60 g approx. MS-EX-F7-2, MS-EX-F7-3 MS-EX-F6-1 MS-EX-F6-2 (PVC mounting bracket) (Note 7):1 pc. (PFA mounting bracket): 1 pc. (PVC mounting bracket): 1 pc. each for two-point-fixing and adhesive-fixing Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Highly viscous liquid may not be detected stably. 3) FluorinertTM is the world wide trademark of 3M. 4) The agents mentioned above are examples. For details, please contact our office. 5) Liquid being detected should also be kept within the rated ambient temperature range. 6) PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. 7) The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor. Leak Detection Sensor EX-F70 SERIES EX-F60 SERIES SPECIFICATIONS FIBER SENSORS LASER SENSORS Simple wire-saving unit Designation Item Model No. Applicable connector Supply voltage Current consumption Output Utilization category Output operation Response time Indicators Input No. Normal Error Output Pollution degree Ambient temperature Ambient humidity Material Cable Cable extension Weight Accessories 856 Simple wire-saving unit for leak detection sensor EX-FC1 SL-CP1 12 to 24 V DC 10 % Ripple P-P 10 % or less 50 mA or less (for the unit itself), 135 mA or less (including the sensor input current when all outputs of sensors are ON) Relay contact 1a * Switching capacity: 30 V 1 A DC (resistive load) * Min. applied load: 10 mV 10 A DC * Electrical lifetime: 100,000 switching operations or more (rated load, switching frequency 20 operations/min.) * Mechanical lifetime: 50 million switching operations or more (switching frequency 180 operations/min.) DC-12 or DC-13 The output relay is ON when the input signal from the sensor is ON (Note 2) 5 ms or less (excluding the response time of the sensor) 8 Nos. Green LED x 8 (light up when the sensor is connected to each channel and the connection setting switch is set to ON) Red LED x 8 (light up when the leak liquid is detected by a sensor connected to each channel or a sensor is mounted improperly) Orange LED [lights up when the output relay is ON (normal)] 3 (Industrial environment) PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS -10 to +60 C +14 to +140 F (No dew condensation or icing allowed), Storage: -20 to +70 C -4 to +158 F STATIC CONTROL DEVICES 35 to 85 % RH, Storage: 35 to 85 % RH ENDOSCOPE Enclosure: ABS, Unit mounting base: POM, Terminal part: PBT 0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long Extension up to total less than 10 m 32.808 ft is possible, with 0.3 mm2, or more, cable. Net weight: 85 g approx. SL-CP1 (Snap male connector): 8 pcs., MS-SL-2 (Unit mounting base): 1 pc., SC-PK (Connector end cap) : 8 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Even with only one leak detection sensor connected, an OFF signal is output if the sensor detects liquid leakage, or if the unit has been installed incorrectly. LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 857 Leak Detection Sensor I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS PHOTOELECTRIC SENSORS EX-F7EX-F6 I/O circuit diagram MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Tr ZD Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 - 50 mA max. 12 to 24 V DC 10 % (Blue) 0 V Load + - 12 to 24 V DC 10 % Load + - 12 to 24 V DC 10 % Blue EX-F6 Brown Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor Blue EX-F7-PNEX-F6-PN PNP output type I/O circuit diagram Wiring diagram EX-F7-PN Color code Brown (Brown) +V ZD Tr Black 50 mA max. + (Black) Output (Blue) 0 V Internal circuit Blue 12 to 24 V DC 10 % - Load D Load + - 12 to 24 V DC 10 % + - 12 to 24 V DC 10 % EX-F6-PN Brown Users' circuit Black Symbols ... D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : PNP output transistor Blue EX-FC1 Load Simple wire-saving unit for leak detection sensor I/O circuit diagram (for one channel) Terminal No. Color code 12 to 24 V DC 10 % 1 IN 3 (Brown) 12 to 24 V DC 10 % 0V 2 Selection Guide Liquid Level Detection + Users' circuit Not connected 4 Liquid Leak Detection Black Load Black *1 Wafer Detection Brown (Black) Output Internal circuit Sensor circuit ENDOSCOPE EX-F7 (Brown) +V MEASUREMENT SENSORS STATIC CONTROL DEVICES Wiring diagram Color code D Sensor circuit AREA SENSORS NPN output type Main circuit LASER SENSORS EX-F70 SERIES EX-F60 SERIES Sensor side (White) OUT (Black) OUT Relay contact (1a) (Blue) 0 V Internal circuit Users' circuit Note: The output does not incorporate a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. *1 Non-voltage contact or NPN open-collector transistor (Amplifier built-in leak detection sensor) or Leak Detection Sensor EX-F70 SERIES EX-F60 SERIES PRECAUTIONS FOR PROPER USE * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. EX-F71(-PN)EX-F72(-PN) Mounting EX-F71(-PN) * Insert the M4 stud-bolt (length 10 mm 0.394 in or more) welded on the user's facilities into the mounting hole of the SUS mounting bracket and screw with an M4 nut (please arrange separately). The tightening torque should be 0.98 N*m or less. SUS plate M4 stud-bolt (Straight type) PHOTOELECTRIC SENSORS Mounting EX-F61(-PN) * Insert the M4 stud-bolt (length 10 mm 0.394 in or more) welded on the user's facilities into the mounting hole of the PFA mounting bracket and screw with an M4 nut (please arrange separately). The tightening torque should be 0.98 N*m or less. M4 nut LIGHT CURTAINS M4 stud-bolt (Straight type) * Please note that if the excess adhesive from the bottom surface of the exclusive mounting bracket is remained, the sensing capability may be affected. Use adhesive for vinyl chloride (PVC). How to fit the sensor body to the exclusive mounting bracket Notches * Use adhesive to stick fast the mounting bracket on the mounting surface. Please note that if the adhesive sticks out from the bottom surface of the mounting bracket or is 0.5 mm 0.020 in, or more thick, the sensor body cannot be fitted to the mounting bracket. PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE Projection MICRO PHOTOELECTRIC SENSORS AREA SENSORS M4 nuts M4 stud-bolts (Straight type) FIBER SENSORS LASER SENSORS EX-F61(-PN)EX-F62(-PN) * Align the projections in the sensor body with the notches of the exclusive mounting bracket and slide till a click is felt. EX-F72(-PN) * Insert M4 stud-bolts (length 10 mm 0.394 in or more) welded on the user's facilities into the mounting holes of the two-point-fixing mounting bracket and screw with M4 nuts (please arrange separately). The tightening torque should be 0.49 N*m or less. Refer to General precautions. EX-F62(-PN) M4 nut 858 How to remove the sensor body from the exclusive mounting bracket * Pinch the projections of the sensor body and pull the body upwards. Never pull the cable, since it may cause a cable break. Projection LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS How to fit the sensor body to the exclusive mounting bracket * Match the notch in the sensor body with the projection of the exclusive Notch mounting bracket and slide till a click is felt. Projection * When mounting, make sure to use the brackets included with the unit in order to eliminate human error (such as forgetting to install). If the included brackets are not used, stable sensing is rendered impossible. Also, because sensitivity settings differ between the EX-F71(-PN) and the EX-F72(-PN), their brackets cannot be interchanged. Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 859 Leak Detection Sensor PRECAUTIONS FOR PROPER USE FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS EX-F70 SERIES EX-F60 SERIES Refer to General precautions. EX-FC1 Mounting Part description LIGHT CURTAINS * When mounting the unit, be sure to use the unit mounting base (MS-SL-2) (accessory). * When installing the unit mounting base to the unit, insert the base aligned with the grooves of the unit and move until the unit stopper is locked. PRESSURE / FLOW SENSORS Grooves MICRO PHOTOELECTRIC SENSORS AREA SENSORS 7 6 5 4 3 2 1 INDUCTIVE PROXIMITY SENSORS 0 PARTICULAR USE SENSORS Unit stopper SENSOR OPTIONS MEASUREMENT SENSORS STATIC CONTROL DEVICES Mounting position 1 Mounting position 2 2 3 4 5 Unit HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 Error indicator (Red LED x 8) Lights up when leak is detected by any sensor connected or any sensor is mounted improperly. (For details, refer to "Connection setting switch".) Output indicator (Orange LED) Lights up when the output relay is ON (Normal). 7 PLC / TERMINALS Function Lights up when sensors are connected to each channel and the connection setting switch is set to ON. 6 ENDOSCOPE LASER MARKERS Designation Normal indicator (Green LED x 8) Unit 1 WIRE-SAVING SYSTEMS * Two installation positions are available for the unit mounting base so that the unit direction can be changed. Install the base at one of them. 0 SIMPLE WIRE-SAVING UNITS Unit mounting base Unit mounting base Connector Din rail stopper Din rail stopper * For removal, insert a flathead screwdriver into the DIN rail stopper and pull towards yourself. In case of using screws * Mount using M4 pan head screws with a tightening torque of 0.8 N*m or less. However, in case of side mounting, make sure to mount the unit such that the unit stopper faces front. Connect the leak detection sensors. Connection In case of using a DIN rail or the mounting bracket (MS-DIN-3) (optional) F it the rear part of the unit mounting base on a 35 mm 1.378 in width DIN rail or the mounting bracket (MS-DIN-3) (optional). P ress down the front part of the unit mounting base on the 35 mm 1.378 in width DIN rail and fit the front part of the base on the DIN rail. Connection setting Set the switch to ON when the leak detection sensor is connected, set to OFF when the leak switch detection sensor is not connected. DIN rail stopper 35 mm 1.378 in width DIN rail or the mounting bracket (MS-DIN-3) (Optional) * Make sure to connect or disconnect the snap male connector (SL-CP1) in the power supply off condition. * Take care that wrong wiring will damage the product. * The terminal No. 4 of the snap male connector (SL-CP1) is not used. Take care not to connect to the terminal No. 4 by mistake. Further, if there are unused wires, please insulate them. 1 2 3 4 Flathead screwdriver * For details of the hook-up method of the snap male connector (SL-CP1), refer to the Instruction Manual enclosed with SL-CP1. DIN rail stopper Unit Unit mounting base Content +V 0V IN No connected M4 pan head screw ( Purchase separately. Unit stopper ) Connection method * By holding the SL-CP1 with the cable connected, insert it into the connector of the EX-FC1 reliably till it stops. EX-FC1 SL-CP1 (Accessory) 7 6 5 4 3 2 Disconnection method * By holding SL-CP1, pull it from the EX-FC1 horizontally. Note: Do not pull out by holding the cable, as this can result in cable disconnection. 1 0 Cable of the leak detection sensor Leak Detection Sensor EX-F70 SERIES EX-F60 SERIES PRECAUTIONS FOR PROPER USE EX-FC1 Connection setting switch * The connection setting should be carried out in the power supply off condition after removing any electrostatic charge which may be present on your body. Operation matrix for each indicator Connection State of the Leak Normal Error state of Output connection detected indicator indicator indicator Operation the leak setting condition (Green) (Red) (Orange) detection switch sensor Connected Normal Error ON Not leaked Leaked Unconnected OFF Connected OFF Not leaked Unconnected ON Lights up Turns off Turns off Lights up Turns off Turns off Lights up Turns off Lights up Lights up Lights up Turns off Lights up Turns off Turns off * For the channel that the unit sensor is connected to and the connection setting switch is set to "ON" side, the error indicator (red) lights up for a moment when the power is turned on. This is not a malfunction for the unit because it is caused by characteristic of the sensor. * Make sure to set the connection setting switch with the connector No. to which the leak detection sensor is connected, to "ON" side. * In case both the normal indicator (green) and the error indicator (red) light up, the connection setting switch with the connector No. to which the leak detection sensor is connected, is not set to "ON" side. Set the connection setting switch with the connector No. to which the leak detection sensor is connected, to "ON" side. * In case the error indicator (red) lights up, the leak detection sensor detects leak or the connection setting switch is set to "ON" side without connecting the leak detection sensor. If the connection setting switch is set to "ON" side without connecting the leak detection sensor, set the connection setting switch to "OFF" side. * If the leak detection sensor detects leak or the connection setting switch is set to "OFF" side in the state that the leak detection sensor is improperly mounted to the mounting bracket, the sensor judges as the output is ON. Be careful when setting. NOT USED These are not used. 7 6 5 6 5 "ON" side 4 4 "ON" side 3 3 "ON" side 2 2 1 1 0 0 "ON" side ON Connection setting switch setting example In case the input of 0, 3, 4 and 5 are set to effective. ( 7 Connector No. ) 860 Refer to General precautions. FIBER SENSORS All models LASER SENSORS Wiring PHOTOELECTRIC SENSORS * Make sure that the power supply is off while wiring. * Verify that the supply voltage variation is within the rating. Take care that if a voltage exceeding the rated range or an AC power supply is directly applied, the sensor may get damaged or burnt. * If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. * In case noise generating equipment (switching regulator, inverter motor,etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. * Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. * Make sure to use an isolation transformer for the DC power supply. If an auto-transformer (single winding transformer) is used, this product or the power supply may get damaged. * In case a surge is generated in the used power supply, connect a surge absorber to the supply and absorb the surge. * Cable extension is possible up to total 50 m 164.05 ft with 0.3 mm2, or more, cable (less than 10 m 32.81 ft for EX-FC1). However, in order to reduce noise, make the wiring as short as possible. * Make sure that stress by forcible bend or pulling is not applied directly to the sensor cable joint. * EX-FC1 output dose not incorporate a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Others * Avoid using the product in an explosive atmosphere because this product does not have an explosive-proof protective construction. * When liquid remains on the sensing surface after leak detection, wipe all liquid from the sensing surface. To avoid scratching the sensing surface and the enclosed mounting bracket, use a soft cloth. * In case air bubbles are drawn into the sensing part, take care that it may take some time for sensing to stabilize, or sensing may even become unstable. Check the usage conditions thoroughly before use. * Do not use during the initial transient time (leak detection sensor: 50 ms approx., EX-FC1: 0.5 sec. approx.) after the power supply is switched on. * Since this sensor employs non-modulated infrared LED, take sufficient care against extraneous light. Do not expose the sensing part directly to the extraneous light. * Avoid dust, dirt, and steam. Further, do not use this product in an environment containing organic solvents. * Take care that EX-7(-PN) and EX-FC1 does not come in contact with oil, grease or organic solvents, such as, thinner, etc. * In case this sensor is used where electrostatic charge is present, use a metal leak pan, which should be connected to an actual ground. * These sensors are only for indoor use. MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 861 FIBER SENSORS LASER SENSORS Leak Detection Sensor EX-F70 SERIES EX-F60 SERIES DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. EX-F71(-PN)EX-F72(-PN) Sensor PHOTOELECTRIC SENSORS Assembly dimensions with mounting bracket for EX-F71(-PN) MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS 16 0.630 26.5 1.043 o2.5 o0.098 cable, 2 m 6.562 ft long PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 35.9 1.413 28.5 1.122 35.9 1.413 28.5 1.122 26.5 1.043 MS-EX-F7-1 SUS mounting bracket ( 13 0.512 NORMAL indicator (Green) ) M4 (length 10 mm 0.394 in) stud-bolt (Note) (Straight type) 10.7 0.421 11 0.433 M4 nut (Note) Note: A M4 stud-bolt has been welded to this unit. M4 nut is not supplied with the sensor. Purchase it separately. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES 5.5 0.217 FAULT indicator (Red) SENSOR OPTIONS MEASUREMENT SENSORS 16 0.630 Assembly dimensions with mounting bracket for EX-F72(-PN) MS-EX-F7-3 / For two-point-fixing MS-EX-F7-2 / For adhesive fixing 35.9 1.413 ENDOSCOPE 35.9 1.413 28.5 1.122 28.5 1.122 LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES 20.7 26.5 0.815 34.7 1.043 1.366 9 0.354 ENERGY CONSUMPTION VISUALIZATION COMPONENTS UV CURING SYSTEMS Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60 ( 13 0.512 FA COMPONENTS MACHINE VISION SYSTEMS MS-EX-F7-3 PVC mounting bracket for two-point-fixing 26.5 34.7 1.043 1.366 MS-EX-F7-2 PVC mounting bracket for adhesive fixing ) ( 2-M4 (length 10mm 0.394 in) stud-bolts (Note) (Straight type) 13 0.512 2-M4 nuts (Note) 11.2 0.441 11.2 0.441 0.5 0.020 Note: M4 stud-bolts have been welded to this unit. M4 nuts are not supplied with the sensor. Purchase it separately. 0.5 0.020 ) Leak Detection Sensor DIMENSIONS (Unit: mm in) EX-F70 SERIES EX-F60 SERIES The CAD data in the dimensions can be downloaded from our website. EX-F61(-PN)EX-F62(-PN) Sensor Assembly dimensions with mounting bracket for EX-F61(-PN) 9 0.354 27 1.063 18 0.709 2-o4.2 o0.165 23 0.906 26 1.024 o2.5 o0.098 cable, 3 m 9.843 ft long PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS NORMAL indicator (Green) PARTICULAR USE SENSORS 19 3 0.188 14 0.748 0.551 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Assembly dimensions with mounting bracket for EX-F62(-PN) 27 1.063 PHOTOELECTRIC SENSORS LIGHT CURTAINS 26 1.024 19 0.748 LASER SENSORS AREA SENSORS Stainless steel bush 17 0.669 FAULT indicator (Red) FIBER SENSORS MICRO PHOTOELECTRIC SENSORS MS-EX-F6-1 PFA mounting bracket 4.5 0.177 NORMAL indicator (Green) 1.5 0.059 FAULT indicator (Red) 862 WIRE-SAVING SYSTEMS MS-EX-F6-2 (PVC mounting bracket) MEASUREMENT SENSORS 21.5 0.846 STATIC CONTROL DEVICES ENDOSCOPE 26 1.024 FAULT indicator (Red) LASER MARKERS NORMAL indicator (Green) PLC / TERMINALS HUMAN MACHINE INTERFACES 19 3 0.188 14 0.748 0.551 ENERGY CONSUMPTION VISUALIZATION COMPONENTS Adhering surface EX-FC1 FA COMPONENTS Simple wire-saving unit for leak detection sensor Normal indicator (Green) Error indicator (Red) MS-DIN-3 Unit mounting bracket (Optional) Output indicator (Orange) 2 0.079 o3.7 o0.146 cable, 2 m 6.562 ft long 20 0.787 14.6 0.575 Connection setting switch 52 2.047 4.4 0.173 8 connectors 15 0.591 UV CURING SYSTEMS 4.4 0.173 18.5 20 0.728 0.787 10 0.394 2 0.079 Selection Guide Wafer Detection Liquid Leak Detection 7 6 5 60.5 2.382 93 3.661 52.5 2.067 4 3 2 9 0.354 13 0.512 4 Unit mounting base (MS-SL-2) 0.157 40 1.575 (11.5) (0.453) 1 0 25.5 1.004 7.5 0.295 18.3 0.720 2-o4.5 o0.177 mounting holes Suitable for 35 mm 1.378 in width DIN rail 29.5 1.161 0.7 0.028 10 0.394 2 0.079 o1.8 o0.071 MACHINE VISION SYSTEMS 35 1.378 22 0.866 15 0.591 2-o4.4 o0.173 holes t1 t 0.039 5.5 0.217 27 1.063 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Liquid Level Detection 2 0.079 Water Detection 0.3 0.012 Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products SQ4 EX-F70/ EX-F60