http://www.tracopower.com Page 2 of 6
AC/DC Power Modules
TMS Series 6 to 25 Watt
Input Specifications
Input voltage range 85 – 264 VAC (110–375 VDC)
Input frequency 47 – 63 Hz
External fuse (required) 1 A slow blow type (recommendation)
Output Specifications
Voltage set accuracy ±2 %
Regulation – Input variation 0.4 % max.
– Load variation (10–90%)
single output models: 1 % max.
dual output models: 2 % typ./5 % max. (symmetric load)
Ripple and noise (20Mhz bandwidth) 100 mV pp typ.
Overload protection by current limit at >130 % Inom. foldback, automatic recovery
(long therm short circuit operation may cause
damage to the unit)
General Specifications
Temperature ranges – Operating –25°C to +60°C ambient temp. max.
– Case temperature +90°C max.
– Storage (non operating) –25°C to +105°C
Derating 5 Vout models: 2.5 %/°K above +40°C
all other models: 5 %/°K above +50°C
Temperature coefficient 0.02 %/°C
Efficiency 78 % typ.
Humidity (non condensing) 85 % rel max.
Switching frequency 100 kHz typ.
Hold-up time – Vin = 115 VAC 20 ms typ.
– Vin = 230 VAC 100 ms typ.
I/O isolation voltage 3‘000 VAC
Leakage current 0.3 mA RMS typ./230 VAC/50 Hz
EMI/RFI conducted EN 55022, level B, FCC Part 15 level B
EMC compliance – Electrostatic discharge ESD IEC/EN 61000-4-2 level 3 6 kV/8 kV
– RF field susceptibility IEC/EN 61000-4-3 10 V/m
– Electrical fast transients/bursts on mainsline IEC/EN 61000-4-4 level 3 2 kV
– Surge IEC/EN 61000-4-5 level 3 1 kV/2 kV
Safety standards UL 60950-1, IEC/EN 60950-1
Safety approvals – UL/cUL 60950-1 www.ul.com -> certifications -> File e141988
– CB report (IEC 60950-1, 2nd edition)
www.tracopower.com/products/tms06-cb.pdf
www.tracopower.com/products/tms10-cb.pdf
www.tracopower.com/products/tms15-cb.pdf
www.tracopower.com/products/tms25-cb.pdf
Environmental compliance – Reach www.tracopower.com/products/tms-reach.pdf
– RoHS RoHS directive 2011/65/EU
Casing material CELANEX (UL 94V-0 rated)
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >250‘000 h
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.