https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Pluggable device protection, according to type 3/class III, for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with integrated surge-proof fuse and remote indication contact. Also suitable for DC applications. Your advantages Varistor-based device protection Can be used without separate backup fuse thanks to integrated overcurrent protection For 1-phase power supply units (AC/DC) Pluggable Optical status indicator via LED With floating remote indication contact Plugs can be checked with CHECKMASTER 2 Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356939676 Weight per Piece (excluding packing) 100.000 g Custom tariff number 85363030 Country of origin Germany Technical data Dimensions Height 90 mm Width 17.7 mm 11/28/2019Page1/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Technical data Dimensions Depth 74.5 mm (incl. DIN rail 7.5mm) Horizontal pitch 1 Div. Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 C ... 80 C Ambient temperature (storage/transport) -40 C ... 80 C Altitude 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 30g (Half-sine / 11 ms / 3x X, Y, Z) Vibration (operation) 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z) General EN type T3 Number of ports One Mode of protection L-N L-PE N-PE (L+) - (L-) (L+/L-) - PE Mounting type DIN rail: 35 mm Color light grey RAL7035 traffic grey A RAL 7042 Housing material PA 6.6-FR 20% GF PA 6.6-FR Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 2 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 24V AC(TN-S) Nominal frequency fN 50 Hz (60Hz) Maximum continuous voltage UC 34 V AC 34 VDC Rated load current IL 26 A (30C) Residual current IPE 5 A Nominal discharge current In (8/20) s 1 kA 11/28/2019Page2/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Technical data Protective circuit Standby power consumption PC 30 mVA (at UREF) 50 mVA (at UC) Reference test voltage UREF 27 V AC Combination wave UOC 2 kV Voltage protection level Up (L-N) 0.25 kV Voltage protection level Up (L-PE) 0.65 kV Voltage protection level Up (N-PE) 0.65 kV TOV behavior at UT (L-N) 50 V AC (5s / withstand mode) 50 V AC (120min / withstand mode) TOV behavior at UT (L-PE) 50 V AC (5s / withstand mode) 50 V AC (120min / withstand mode) Response time tA (L-N) 25 ns Response time tA (L-PE) 100 ns Response time tA (N-PE) 100 ns Short-circuit current rating ISCCR 1.5 kA AC 1 kA DC Max. backup fuse with branch wiring not required Maximum backup fuse for through wiring 25 A (gG / B / C) Indicator/remote signaling Switching function N/C contact Operating voltage 250 V AC 125 VDC (200 mA DC) Operating current 3 A AC 1 A DC (30 V DC) Connection method Screw connection Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section solid 0.2 mm ... 4 mm Conductor cross section AWG 24 ... 12 Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm Connection data Connection method Screw connection Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section solid 0.2 mm ... 4 mm Conductor cross section AWG 24 ... 12 11/28/2019Page3/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Technical data Connection data Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm UL specifications SPD Type 4CA Maximum continuous operating voltage MCOV 34 V AC 34 VDC Nominal voltage 24 VDC Rated load current IL 25 A Mode of protection L-N L-G N-G (L+) - (L-) (L+) - G (L-) - G Power distribution system Single phase Nominal frequency 50/60Hz Measured limiting voltage MLV (L-N) 290 V Measured limiting voltage MLV (L-G) 560 V Measured limiting voltage MLV (N-G) 560 V Measured limiting voltage MLV (L+) - (L-) 290 V Measured limiting voltage MLV (L+) - G 560 V Measured limiting voltage MLV (L-) - G 560 V Nominal discharge current In 1 kA UL indicator/remote signaling Tightening torque 5 lbf-in. ... 7 lbf-in. Conductor cross section AWG 14 ... 12 UL connection data Conductor cross section AWG 14 ... 12 Tightening torque 5 lbf-in. ... 7 lbf-in. Standards and Regulations Standards/specifications IEC61643-11 2011 EN61643-11 2012 Environmental Product Compliance Lead 7439-92-1 11/28/2019Page4/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Technical data Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Product drawing 11/28/2019Page5/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Diagram Nominal current depending on ambient temperature Dimensional drawing 11/28/2019Page6/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Circuit diagram Classifications eCl@ss eCl@ss 4.0 27130800 eCl@ss 4.1 27130800 eCl@ss 5.0 27130800 eCl@ss 5.1 27130800 eCl@ss 6.0 27130800 eCl@ss 7.0 27130806 eCl@ss 8.0 27130806 eCl@ss 9.0 27130806 ETIM ETIM 5.0 EC000942 ETIM 6.0 EC000942 ETIM 7.0 EC000942 UNSPSC UNSPSC 13.2 39121620 Approvals Approvals 11/28/2019Page7/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Approvals Approvals GL / CCA / KEMA-KEUR / IECEE CB Scheme / EAC / UL Recognized Ex Approvals cULus Recognized Approval details GL CCA https://approvalfinder.dnvgl.com/ 14588-15 HH NTR-NL 7399 KEMA-KEUR http://www.dekra-certification.com 2173868.01 IECEE CB Scheme http://www.iecee.org/ NL-35777 EAC RU CDE.A*30.B01561 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 Accessories Accessories Device marking 11/28/2019Page8/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Accessories Label-EML (20XE)R-0803452 Label, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK ROLL X1, THERMOMARK ROLL 2.0, THERMOMARK ROLL, mounting type: adhesive, lettering field size: continuous x 20 mm Label-EML (20XE)R YE-0803453 Label, Roll, yellow, unlabeled, can be labeled with: THERMOMARK ROLLMASTER 300/600, THERMOMARK X1.2, THERMOMARK ROLL X1, THERMOMARK ROLL 2.0, THERMOMARK ROLL, mounting type: adhesive, lettering field size: continuous x 20 mm End block End clamp-CLIPFIX 35-3022218 Quick mounting end clamp for NS 35/7,5 DIN rail or NS 35/15 DIN rail, with marking option, width: 9.5 mm, color: gray Marker pen Marker pen-X-PEN 0,35-0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm Spare parts 11/28/2019Page9/10 https://www.phoenixcontact.com/us/products/2905223 Type 3 surge protection device-PLT-SEC-T3-24-FM-2905223 Accessories Type 3 surge protection plug-PLT-SEC-T3-24-P-2905232 Replacement plug for type 3 device protection from the PLUGTRAB SEC T3 product range. 24 V nominal voltage. Phoenix Contact 2019 (c) - all rights reserved http://www.phoenixcontact.com 11/28/2019Page10/10