1
Switching Power Supply S82H
Switching Power Supply
S82H
Industrial Power Supply with Power
Factor Correction Available
Models range from 15 to 150 W.
120/240 selectable on 15 to 150 W Models.
All meet UL and CSA standards.
100 to 150 W models also have VDE and CE
approvals.
3-year warranty.
Ordering Information
NON-PFC TYPE SWITCHING POWER SUPPLIES
Stock Note: Shaded models are normally stocked.
Rated input voltage Power ratings Output voltage Output current Part number
120/240 VAC selectable 15 W 5 V 3 A S82H-3105
120/240 VAC selectable
15 W
12 V 1.2 A S82H-3112
15 V 1 A S82H-3115
24 V 0.6 A S82H-3124
30 W 5 V 6 A S82H-3305
30 W
12 V 2.5 A S82H-3312
15 V 2 A S82H-3315
24 V 1.3 A S82H-3324
50 W 5 V 10 A S82H-3505
50 W
12 V 4.5 A S82H-3512
15 V 3.4 A S82H-3515
24 V 2.3 A S82H-3524
100 W 5 V 20 A S82H-10005
12 V 9 A S82H-10012
15 V 7.2 A S82H-10015
24 V 4.6 A S82H-10024
150 W 5 V 30 A S82H-15005
12 V 13.5 A S82H-15012
15 V 10 A S82H-15015
24 V 7 A S82H-15024
2Switching Power Supply S82H
ACCESSORIES (ORDER SEPARATELY)
Stock Note: Shaded models are normally stocked.
Item Applicable power supplies Mounting type Part number
Mounting bracket S82H-31 (15 W) Bottom mounting S82Y-H01B
Mounting bracket
S82H-31 (15 W)
Side mounting S82Y-H01S
Front/flush mounting S82Y-H01F
DIN-rail mounting bracket S82Y-01N
DIN rail PFP-100N2
PFP-50N
PFP-100N
Mounting bracket S82H-33 (30 W) Bottom mounting S82Y-H03B
Mounting bracket
S82H-33 (30 W)
Side mounting S82Y-H03S
Front/flush mounting S82Y-H03F
DIN-rail mounting bracket S82Y-03N
DIN rail PFP-100N2
PFP-50N
PFP-100N
Mounting bracket S82H-35 (50 W) Bottom mounting S82Y-H05B
Mounting bracket
S82H-35 (50 W)
Side mounting S82Y-H05S
Front/flush mounting S82Y-H05F
DIN-rail mounting bracket S82Y-05N
DIN rail PFP-100N2
PFP-50N
PFP-100N
Mounting bracket S82H-100 (100 W) Bottom mounting S82Y-H10B
Mounting bracket
S82H-100 (100 W)
Side mounting S82Y-H10S
Front/flush mounting S82Y-H10F
S82H-150 (150 W) Bottom mounting S82Y-F15B
S82H-150 (150 W)
Side mounting S82Y-F15S
Front mounting/back
mounting –––––
Mounting bracket S82H-P300 (300 W) Bottom mounting S82Y-D30B
Mounting bracket
S82H-P300 (300 W)
Side mounting S82Y-D30S
Front mounting/back
mounting –––––
S82H-P600 (600 W) Bottom mounting S82Y-D60B
S82H-P600 (600 W)
Side mounting S82Y-D60S
Front mounting/back
mounting –––––
Fan S82H-P300 S82Y–DFAN
Fan
S82H-P600
S82Y–DFAN
Terminal expansion bracket S82H-P600 S82Y–D60T
3
Switching Power Supply S82H
MODEL NUMBER LEGEND
15 to 50 W Models
S82H - 3 -
1 2
1. Power ratings
1: 15 W
3: 30 W
5: 50W
2. Output voltage
05: 5 V
12: 12 V
15: 15 V
24: 24 V
100 to 600 W Models
S82H - 21
1. Output Capacity
100: 100 W
150: 150 W
300: 300 W
600: 600 W
2. Output Voltage
05: 5 V
12: 12 V
15: 15 V
24: 24 V
Specifications
NON-PFC TYPE SWITCHING POWER SUPPLIES (15 W, 30 W, 50 W)
Power ratings 15 W 30 W 50 W
Efficiency (typ.) 70% to 80% (24 V)
Input
Operating voltage AC 85 to 132 VAC/170 to 264 VAC (selectable)
DC No
Frequency 47 to 450 Hz
Current at rated Input
voltage and rated out-
At 100-V input 0.5 A max. 0.9 A max. 1.3 A max.
voltage and rated out-
put voltage/current At 200-V input 0.3 A max. 0.6 A max. 0.8 A max.
Leakage current at
rated input voltage and
output voltage current
At 100-V input 0.5 mA max.
rated input voltage and
output voltage current
(See Note 2.) At 200-V input 1 mA max.
Inrush current at rated
input voltage and rated
output voltage/current
At 100-V input 25 A max.
input voltage and rated
output voltage/current
(See Note 2.) At 200-V input 50 A max.
Noise filter Provided
Output
Voltage adjustment ±10% (adjustable with variable resistor V–ADJ)
Ripple and noise 2% (p-p) max.
Regulation, line 0.5% max. (at 85 to 132/170 to 264 V input, 100% load)
Regulation, load 2% max. (at rated input, 10 to 100% load)
Temperature coefficient 0.05%/°C max. ( at rated input/output in range of 0° to 40°C)
Rise time 200 ms max. (90% output voltage rise at rated input voltage and rated output
voltage/current)
Hold up time 20 ms min. (90% output voltage rise at rated input voltage and rated output
voltage/current)
Additional functions
Overload protection 120% of rated output current typ., inverted L trailing, automatic reset
Overvoltage protection No
Remote sensing No
Remote control No
(This table continues on the next page.)
4Switching Power Supply S82H
Specifications Table – continued from previous page
Power ratings 15 W 30 W 50 W
Characteristics
Temperature Operating See Derating Curve in Engineering Data.
Storage -20° to 85°C (–40° to 185°F)
Humidity Operating: 30 to 90% RH; Storage: 20 to 95% RH
Dielectric strength 2,000 VAC, 50/60 Hz, for 1 minute (between input terminals and output terminals/housing) 500
VDC for 1 minute (between output terminals and input terminals/housing) Refer to Note 3 (on
the next page).
Insulation resistance 100 M min. (between output terminals and input terminals/housing)
Vibration 10 to 55 Hz, 0.75 mm double amplitude (approx. 4.5 G) in 3 directions, respectively for 2 hours
Shock 294 m/s2 (30 G) in 6 directions, respectively 3 times
Output indicator Red LED
Heat radiation 1.9 cal/sec 3.2 cal/sec 4.7 cal/sec
Electro Magnetic Interference FCC Class B
Mean Time Between Failures 100,000 hours min.
Approved standards UL (E105544), CSA (LR63986)
Weight 400 g max. 520 g max. 660 g max.
NON-PFC TYPE SWITCHING POWER SUPPLIES (100 W, 150 W)
Power ratings 100 W 150 W
Efficiency 70% to 86% (depending on the model)
Life expectancy (See Note 1.) 10 years min. in standard installation conditions at 40°C (104°F) at the rated input with 50% load.
Input
Voltage 100 to 120 VAC/200 to 240 VAC automatically selected (85 to 132 VAC/170 to 264 VAC)
Frequency 47 to 450 Hz
Current at 100-V input 2.5 A
max. 4 A max.
at 200-V input 1.5 A
max. 2.5 A max.
Leakage
current (See
at 100-V input 0.5 mA max.
current (See
Note 2.) at 200-V input 1 mA max.
Inrush current
(See Note 2)
at 100-V input 25 A max.
Inrush current
(See Note 2) at 200-V input 50 A max.
Power factor 0.5 to 0.7 (depending on the model)
Output
Voltage adjustment range ±10% (adjustable with variable resistor (V.ADJ))
Ripple 2% (p-p) max.
Input variation influence 0.4 % max. (at 85- to 132-VAC/170- to 264-VAC input, 100% load)
Load variation influence 0.8% max. (with rated input voltage, 0 to 100% load)
Temperature variation influence 0.05%/°C max. with rated I/O at an ambient temperature range between -10°C to 50°C
Rise Time 0.8 s max. (Rises up to 90% of the rated voltage under rated input.)
Hold time 20 ms min.
(This table continues on the next page.)
5
Switching Power Supply S82H
Specifications Table – continued from previous page
Power ratings 100 W 150 W
Additional functions
Overload protection 105% max. of rated load current, inverted L drop type, automatic reset
Overvoltage protection 120% of rated output voltage (typical), shutoff type, input reset
Parallel operation No Yes, up to five units
Series operation Yes
Remote sensing Yes
Remote control No Yes
Remote voltage adjustment Yes
Cooling method Natural air-cooling used
Fan alarm function No
Characteristics
Ambient
temperature
Operating See the derating curve in the Engineering Data section. (No condensation or icing.)
Ambient
temperature Storage –25°C to 65°C (–13°F to 149°F) with no condensation or icing
Ambient operating humidity 25% to 85%
Dielectric strength 3 kVAC, 50/60 Hz for 1 min between all inputs and all outputs with a current leakage of 25 mA max.
2.5 kVAC, 50/60 Hz for 1 min between all inputs and GR terminals with a current leakage of 25 mA
max.
1.0 kVAC, 50/50 Hz for 1 min between all outputs and GR terminals with a current leakage of 15 mA
max. for each 100-W model, 20 mA max. for each 150-W model.
Insulation resistance 100 M min. between all outputs and all inputs/GR terminals at 500 VDC
Vibration
resistance Malfunction 10 to 55 Hz, 0.375-mm single amplitude for 2 hrs each in X, Y, and Z directions
Shock
resistance Malfunction 300 m/s2 (approx. 30G), 3 times each in ±X, ±Y, and ±Z directions
Output indicator Yes (green)
EMC Emission Enclosure (See Note 4.): EN55022 Group 1 class B
Emission AC Mains: EN55022 Group 1 class B
Immunity ESD: EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge
(level 3)
Immunity RF-interference: ENV50140:10 V/m (10 k to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141:10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line
(level 4)
Limits for harmonic current
emission ---
EMC standards Conforms to EN50081-1, EN50082-2
Electromagnetic interference Conforms to FCC class B, EN50081–1
Approved standards UL1012, CSA E.B. 1402C, VDE 0160, IEC 950, EN 60950, CE
Weight 950 g
max. 1,800 g max.
Note: 1. The fan is one of the replacement parts (300- and 600-W models).
2. As defined with the rated input voltage and rated output voltage/current.
3. A surge absorber is provided for the input circuits. To test the dielectric strength and insulation resistance of these models,
remove the short bar attached across the GR and ACG terminals.
4. To ensure emission enclosure rating, ferrite cores should be used on all cabling.
6Switching Power Supply S82H
Engineering Data
DERATING CURVE
Note: The derating curve differs depending on the mounting position of the power supply.
15, 30, 50 W Models
100 and 150 W Models
Standard Mounting
Load (%)
Ambient temperature (C)
Natural air
cooling
Forced-air
cooling
Standard Mounting
Load (%)
Ambient temperature (°C)
Natural air cooling
Forced-air
cooling
MOUNTING POSITION
Standard Mounting Horizontal Mounting
(100- and 150-W Models Only)
Side Mounting
(150-W Models Only)
Note: 1. Forced-air cooling must be applied at an minimum air capacity rate of 1 m3/min.
2. Units cannot be mounted vertically.
7
Switching Power Supply S82H
OVERLOAD PROTECTION
The Power Supply is provided with an overload protection
function that protects the load and the power supply from
possible damage by overcurrent. When the output current rises
above a set value (105% of the rated output current for S82H),
the protection function is triggered, decreasing the output
voltage. When the output current falls within the rated range, the
overload protection function is automatically cleared.
15-/30-/50-/100- and 150-W Models
Rated
voltage
Output current (%)
Output voltage (V)
Note:If the product is continuously used under short-circuit or overcurrent conditions, deterioration or damage to internal elements may
occur.
OVERVOLTAGE PROTECTION
All Except 15, 30, and 50 W Models
The Power Supply is provided with an overvoltage protection
function that protects the load and the Power Supply from
possible damage by overvoltage. When the output voltage rises
above a set value (120% of the rated output voltage), the
protection function is triggered, shutting off the output voltage. If
this occurs, reset the S82H by turning it off for more than 1
minute and then turning it on again.
Overvoltage
Variable
Rated output
voltage –10%
+10%
Approx. +20%
Output voltage (V)
8Switching Power Supply S82H
INRUSH CURRENT, START UP TIME, HOLD TIME
15 50 W Models
AC input voltage
AC input current
Output voltage
Inrush current on input application
Start up time
200 ms (max.) Hold time
20 ms (min.)
Input ON Input OFF
INRUSH CURRENT, START UP TIME, HOLD TIME
100 – 600 W Models
Start up time
0.8 Sec Max (Non-PFC)
1 Sec Max (PFC) Hold time
20 ms (max.)
Input OFF
Input ON
AC input voltage
Inrush current when input is turned ON
Output voltage
AC input current
9
Switching Power Supply S82H
Nomenclature
TERMINAL ARRANGEMENT
S82H100

(100 W) S82H150

(150 W)
1. DC output terminals: Connect the load lines to these terminals.
2. Input terminals L and N (with fuse inserted into the L side): Connect the input lines to these terminals.
3. Output voltage adjustment trimmer V.ADJ (with adjustment range of ±10% of rated output): Adjusts the output voltage.
4. Output indicator DC ON: Lit while a DC output is ON.
5. Remote sensing terminals: Corrects the voltage drop in the load lines.
6. Remote control terminals: Enables external signals to turn the output ON and OFF while the input voltage is imposed. The
terminals are short-circuited with a short bar before shipping.
7. ACG terminal: The intermediate point of the input filter. The terminal is short-circuited to the GR terminal before shipping.
8. GR/FG terminal: Shorted to the housing. Ground the Power Supply through this terminal.
9. Fan alarm terminals FAN ALM: Turns ON when the revolution of the built-in fan drops.
10. Output voltage monitor terminals: Connected to the DC output terminals internally. No output current can be obtained from
these terminals. Short-circuit the terminals to the remote sensing terminals +S and –S if the remote sensing function is not
used.
11. Input voltage selector and terminals: Switch the input voltage by connecting or removing the short bar (short circuit:
100–120V; Open circuit: 200–240V)
12. Short bar
(1)
(5)
(3)
(5)
(7)
(2)
(4)
(12)
(8)
(5)
(3)
(4)
(1)
(5)
(2)
(6)
(12
)
(7)
(8)
S82H-31

S
82H-33
S
82H-35
V ADJ DC ON
OUTPUT
+V
24
VDC
0.6A
-V
FG
L
N
INPUT
S82H-3124
(3)
(1)
(7)
(4)
(2)
(11)
(8)
10 Switching Power Supply S82H
Operation
REMOTE SENSING FUNCTION
The remote sensing function makes it possible to compensate for
voltage drops caused by load lines. To use this function, remove
the short bar from the remote sensing terminals and wire the
Power Supply and load as shown in the following illustration. The
remote sensing terminals are short-circuited with the short bar
before shipping.
1
00-W and 150-W Models
Load connection lines
Remote sensing connection
(2-conductor shielded wire) Remove
short bars.
Level Output voltage
L (0.8 V max.) ON
H (2 V min.) OFF
Note:No output will be produced if the terminals are left
unconnected. B e sure to firmly tighten the terminal screws.
BLOCK DIAGRAMS
S82H-31
S82H-33
S82H-35
ACG
FG
L
INPUT
N
120/240 V selector
Fuse *
Noise
filter
Inrush current
protection circuit
Smoothing
circuit Rectifier Rectifier
Control circuit
Overload
detector
+V
–V
DC OU
T
Photocoupler
* Fuse Capacity
15 W: 2 A
30 W: 2.5 A
50 W: 3 A
11
Switching Power Supply S82H
S82H-100 (100 W)
S82H-150 (150 W)
Noise filter
Inrush cur-
rent limiting Rectification/
Smoothing
100/200 V auto-
matic selection
Rectification/
Smoothing
Photocoupler
Control circuit
Overcurrent
detection
Auxiliary power supply circuit
150-W models only
Overvoltage
detection
Detection Remote
sensing
Remote
control
Fuse*
* Fuse capacity
100 W: 5 A
150 W: 7 A
Input
DC output
Load
Load
GENERATING OUTPUT VOLTAGE (±)
The output of two Power Supplies can be combined in
series.
An output of ± can be generated by using two power supplies
(as shown below) because the power supply produces a
floating output.
SERIES OPERATION
The output of two power supplies can be combined in series.
Load
PARALLEL OPERATION
Parallel operation is possible by simply connecting the output
terminals in parallel. (Other than 100 W models)
Using the output voltage adjustment trimmer, adjust the
output of each power supply to the same value.
Operate the Power Supplies connected in parallel at 80% of
the rated output current.
Load
12 Switching Power Supply S82H
Dimensions
Unit: mm (inch)
SWITCHING POWER SUPPLIES
S82H-31
MAX
25
35
(1.38)
90
(3.54)
100 (3.94)
Eight M4 terminal screws
Two M3 screws
15 70 (2.76)
17.5 (0.69)
70
(2.76)
Two 4 dia. holes
Bottom mounting
Mounting Holes –
S82H-33
MAX
25
40
(1.57)
90
(3.54)
130 (5.12)
Eight M4 terminal
screws
Two M3 screws
15 100 (3.94)
20 (0.79)
100
(3.94)
Two 4 dia. holes
Mounting Holes
S82H-35
MAX
25
45
(1.77)
90
(3.54)
150 (5.91)
Eight M4 terminal
screws
Two M3 screws
15 120 (4.72)
22.5
Mounting Holes
120
(4.72)
Two 4 dia. holes
13
Switching Power Supply S82H
35
(1.38)
S82H100 (100 W)
M4 terminal screws Four, M4 , depth: 6 max.
Four, M3,
depth: 6
max.
Four, 5 dia.
Four, 4 dia.
25 max. Mounting Holes
(A)
(B)
(A): Compatible with conventional S82H (100 W) models
(B): Compatible with S82P (100 W) discontinued models
200
(7.87)
60
(2.36)
110
(4.33)
160
(6.30)
160
(6.30)
20
(0.79)
12.5
(0.49)
30 (1.18)
30
(1.18)
17.5
(0.69)
20
(0.79)
30 (1.18)
160 (6.30)
160 (6.30)
Four, M4 holes, depth: 6 max. (incl opposite side)
Four, M3 mtg brkt
holes, depth: 4
35 (1.38)
35
(1.38)
S82H150

(150 W)
Four, M4 holes, depth: 6 max.
(facing side only) Mounting Holes
Bottom Mounting
80 (3.15)
M4 terminal screws
Four, 5 dia.
Four, 5 dia.
74
(2.91)
120
(4.72)
230 (9.06)
160 (6.30)
200 (7.87)
20
(0.79)
12.5
(0.49)
12.5
(0.49)
20
(0.79)
45
(1.77)
80
(3.15)
45
(1.77)
7.5
(0.30) 45
(1.77)
12.5
(0.49)
20
(0.79)
Four, M3 mtg brkt holes, depth: 4 (incl opposite side)
Side Mounting
45
(1.77)
160 (6.30)
160 (6.30)
160 (6.30)
25 max.
20
7.5
(0.30)
14 Switching Power Supply S82H
MOUNTING BRACKET
Bottom-Mounting Bracket
S82Y-H01B (15 W)
Two 4.5 dia. holes
35
(1.38)
20 (0.79)
5
110
120 (4.72)
S82Y-H03B (30 W)
Two 4.5 dia. holes
40
(1.57)
20 (0.79)
5
140
150 (5.91)
20 (0.79)
S82Y-H05B (50 W)
Two 4.5 dia. holes
45
(1.77)
22.5 (0.89)
5
160
170 (6.69)
22.5 (0.89)
S82Y-H10B (100 W)
Three, 4.5-dia holes
230 (9.06)
218
20 (0.79)
20 (0.79)
30
30
6
S82Y-F15B (150 W)
Note: Use countersink screws of M4 x 8 max. when attaching to
the unit.
Three, 4.5-dia. holes
280 (11.02)
248 (9.76)
160 (6.30)
74
(2.91) 40
(1.57)
6
37
17.5
17.5
17
29
15
Switching Power Supply S82H
Unit: mm (inch)
Side-Mounting Bracket
S
82Y-H03S (30 W)
S82Y-H01S (15 W)
S
82Y-H05S (50 W)
Two
4.5 dia.
holes
45 (1.77)
70±0.2
100 (3.94) 15
15 5
10
15 (0.59)
Two
4.5 dia. holes
50 (1.97)
100±0.2
130 (5.12) 1515
10
20 (0.78)
10
Two
4.5 dia. holes
55 (2.16)
120±0.2
150 (5.91)
15
15
10
20 (0.7
8)
10
16 Switching Power Supply S82H
S82Y-H10S (100 W)
eft-side mounting Right-side mounting
Three,
4.5-dia holes
200 (7.87)
85
(3.35)
70
(2.76)
85
(3.35)
10
30
10
S82Y-F15S (150 W)
Note: Use countersink screws of M4 x 8 max. when attachin
g
to the unit.
Four, 4.5-dia. holes
180 (7.09)
160 (6.30)
138
(5.43)
80
(3.15)
150
(5.91)
10
29
6
17
Switching Power Supply S82H
Front/Flush Mounting Bracket
40
(1.57)
S82H-H03F (30 W)
S82Y-H01F (15 W)
S82H-H05F (50 W)
Three 4.5 dia. holes
35
(1.38)
105 (4.13)
Three 4.5 dia. holes
30
(1.18)
40
(1.57)
135 (5.31)
Three 4.5 dia. holes
35
(1.38)
45
(1.77)
45
(1.77)
155 (6.10)
25
(0.98)
35
(1.38)
10 10
10
10 10
15
15 15
20
S82Y-H10F (100 W)
Three, 4.5-dia holes
60
(2.36)
60
(2.36)
40
(1.57)
205 (8.07)
20 20
20
18 Switching Power Supply S82H
OTHER ACCESSORIES AND ATTACHMENTS FOR S82H150 (150 W)
Using the mounting brackets supplied with the unit, the unit can be attached in two directions.
Bottom or Side Mounting Bracket (Included as an Attachment)
Side mountingBottom mounting
Two, 3.2 dia (for mounting the unit) Two, 5 dia. mounting holes
60
(2.36) 45
(1.77)
20
(0.79)
40
(1.57)
15
(0.59)
1012.5
Note: Using two screws, attach the mounting bracket to the unit and then attach it to the panel.
DIN-RAIL MOUNTING BRACKET
S82Y-01N (15 W)
S82Y-03N (30 W)
S82Y-05N (50 W)
Power Supply DIN-rail mounting bracket Two, 4.5 dia holes
DIN rail
L1
L2
58 (2.28)
47
(1.85)
47
(1.85)
104
(4.09)
Item S82Y-01N S82Y-03N S82Y-05N
Applicable power supply S82H-31 S82H-33 S82H-35
Dimensions L1 113 mm (4.45) 143 mm (5.63) 163 mm (6.42)
Dimensions L2 114.8 mm (4.52) 144.8 mm (5.70) 164.8 mm (6.49)
Note: The figures in row L1 apply if a mounting bracket is attached to the power supply. The figures in row L2 apply if PFP-50N or
PFP-100N DIN rail is used. Add 10.5 mm to each figure in the L1 row if PFP-100N2 DIN rail is used.
DIN RAIL
4.5
15 25 25 25 25
10 10
1,000 (500)
(See Note.)
7.3
35 27
1
15 (5)
(See Note.)
Note: The values shown in parentheses are for the PFP-50N.
PFP-100N/PFP-50N
4.5
15 25 25 25 25 15
10 10
1,000
35 27 24
16
29.2 (1.15
)
1 1.5
PFP-100N2
19
Switching Power Supply S82H
Precautions
MOUNTING
Note: Be careful not to impose any excessive vibration or impact
when installing.
To improve and maintain the reliability of the Power Supply
over a long period of time, adequate consideration must be
given to heat dissipation.
Mount the Power Supply so that air flow takes place around
the Power Supply. The Power Supply is designed to dissipate
heat through natural air-flow.
It is recommended that the Power Supply be mounted on a
metal plate.
Air
Metal plate
Provide at least the spaces listed in the following table.
Model *1 *2 *3 *4 *5
100W,
150W 30 mm
(1.18) 50 mm
(1.97) 20 mm
(0.78) 20 mm
(0.78) 20 mm
(0.78)
300W 30 mm
(1.18) 50 mm
(1.97) 20 mm
(0.78) 50 mm
(1.97) 40 mm
(1.57)
600W 30 mm
(1.18) 50 mm
(1.97) 20 mm
(0.78) 70 mm
(2.76) 50 mm
(1.97)
Forced-air cooling is recommended.
Don’t expose the product to the direct sunlight.
Be careful not to allow any machining chips or dust into the
product while fabricating mounting plates.
Don’t use the product where fluids, foreign matter, or corro-
sive gases may enter the product.
Provide at least the spaces listed in the following table.
WIRING PRECAUTIONS
The Power Supply is provided with reinforced insulation between
the primary and secondary terminals. When using the secondary
circuit as an SELV circuit, the circuit connected to the output
terminals and auxiliary function terminals must be a SELV circuit.
20 Switching Power Supply S82H
Certain Terms and Conditions
1. Offer; Acceptance. These terms and conditions (these “Terms”) are
deemed part of all catalogs, manuals or other documents, whether elec-
tronic or in w riting, r elating t o t he s ale o f g oods or services (collectively, the
“Goods”) by Omron Electronics LLC and its subsidiary companies (“Sell-
er”). Seller hereby objects to any terms or conditions proposed in Buyer’s
purchase order or other documents w hich a re inconsistent with, o r in addi-
tion to, these Terms. Please contact y our Omron representative to confirm
any additional terms for sales from your Omron company.
2. Prices. All prices stated are current, subject to change without notice by
Seller. Buyer agrees to pay the price in effect at time of shipment.
3. Discounts. Cash discounts, if any, will apply only on the net amount of in-
voices sent to Buyer after deducting transportation charges, taxes and du-
ties, and will be allowed only if (i) the invoice is paid according to Seller ’s
payment terms and (ii) Buyer has no past due amounts owing to Seller.
4. Orders. Seller will accept no order less than $200 net billing.
5. Governmental Approvals. Buyer shall be responsible for, and shall bear
all costs involved in, obtaining any government approvals required for the
importation or sale of the Goods.
6. Taxes. All taxes, duties and other governmental charges (other than gen-
eral real property and income taxes), including any interest or penalties
thereon, imposed directly or indirectly on Seller or required to be collected
directly or indirectly by Seller for the manufacture, production, sale, deliv -
ery, importation, consumption or use of the Goods sold hereunder (includ-
ing customs d uties a nd s ales, e xcise, u s e, t urnover a nd l icense t axes) shall
be charged to and remitted by Buyer to Seller.
7. Financial. If t he f inancial p osition o f B uyer a t a ny t ime b ecomes u nsatisfac-
tory to S eller, Seller reserves t he r ight t o s top s hipments o r r equire s atisfac-
tory security or payment in advance. If Buyer fails to make payment or
otherwise comply with these Terms or any related agreement, Seller may
(without liability and in addition to other remedies) cancel any unshipped
portion of Goods sold hereunder and stop any Goods in transit until Buyer
pays all amounts, including amounts payable hereunder, whether or not
then due, which are owing to it by Buyer. Buyer shall in any event remain
liable for all unpaid accounts.
8. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Seller fully against all costs or expenses arising
in connection therewith.
9. Force Majeure. Seller shall not be liable for any delay or failure in d elivery
resulting from causes beyond its control, including earthquakes, fires,
floods, strikes or other labor disputes, shortage of labor or materials, acci-
dents t o m achinery, acts o f s abotage, r iots, d elay i n o r l ack o f t ransportation
or the requirements of any government authority.
10. Shipping; Delivery. Unless otherwise expressly agreed in writing by Seller:
a. Shipments shall be by a carrier selected by Seller;
b. Such carrier shall act as the agent of Buyer and delivery to such carrier
shall constitute delivery to Buyer;
c. All sales and shipments of Goods shall be FOB shipping point (unless
otherwise stated in writing by Seller), at which point title to and all risk
of loss of the Goods shall pass from Seller to Buyer, provided that Seller
shall retain a security interest in the Goods until the full purchase price
is paid by Buyer;
d. Delivery and shipping dates are estimates only.
e. Seller will package Goods as it deems proper for protection against
normal handling and extra charges apply to special conditions.
11. Claims. Any claim by Buyer against Selle r for shortage or damage to the
Goods occurring before delivery to the c arrier must be presented in writing
to S eller w ithin 3 0 d ays o f r eceipt o f s hipment a nd i nclude t he o riginal trans-
portation bill signed b y t he c arrier n oting t hat t he c arrier r eceived t he G oods
from Seller in the condition claimed.
12. Warranties. ( a) Exclusive Warranty. Seller’s exclusive warranty is that the
Goods will be free from defects in materials and workmanship for a period
of twelve months from the date of sale by Seller (or such other period ex-
pressed in writing by Seller). Seller disclaims all o ther warranties, e xpress
or implied. (b) Limitations. SELLER MAKES NO WARRANTY OR REP-
RESENTATION, EXPRESS OR IMPLIED, ABOUT NON–INFRINGE-
MENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PUR-
POSE OF THE GOODS. BUYER ACKNOWLEDGES THAT IT ALONE
HAS DETERMINED T HAT THE GOODS WILL SUITABL Y M EET T HE R E-
QUIREMENTS OF THEIR INTENDED USE. Seller further disclaims all
warranties and responsibility of any type for claims or expenses based on
infringement by the Goods or otherwise of any intellectual property right.
(c) Buyer Remedy. Seller ’s sole obligation hereunder shall be to replace
(in the form originally shipped with Buyer responsible for labor charges for
removal or replacement thereof) the non–complying Good or, at Seller’s
election, to repay or credit Buyer an amount equal to the purchase price
of the Good; provided that in no event shall Seller be responsible for war-
ranty, repair, indemnity or any other claims or expenses regarding the
Goods unless Seller’s a nalysis c onfirms that the G oods w ere p roperly h an-
dled, stored, installed and maintained and not subject to contamination,
abuse, misuse or inappropriate modification. Return of any goods by Buy-
er must be approved in writing by Seller before shipment. Seller shall not
be liable for the suitability or unsuitability or the results from the use of
Goods in combination with any electrical or electronic components, cir-
cuits, system assemblies or any other materials or substances or environ-
ments. Any advice, recommendations or information given o rally o r i n w rit-
ing, are not to be construed as an amendment or addition to the above
warranty.
13. Damage L imits; E tc. SELLER S HALL N OT B E L IABLE F OR S PECIAL, I N-
DIRECT OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED
WITH THE G OODS, WHETHER S UCH C LAIM I S B ASED I N C ONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event
shall liability of Seller exceed the individual price of the Good on which li-
ability is asserted.
14. Indemnities. Buyer shall indemnify and hold harmless Seller, its affiliates
and its employees from and against all liabilities, losses, claims, costs and
expenses (including a ttorney’ s f ees a nd e xpenses) r elated t o any claim, i n-
vestigation, litigation or proceeding (whether or not Seller is a party) which
arises or is alleged to arise from Buyer’s acts or omissions under these
Terms or i n a ny way with r espect to the G oods. Without l imiting t he f orego-
ing, Buyer (at its own expense) shall indemnify and hold harmless Seller
and defend or settle any action brought against Seller to the extent that it
is based on a claim that any Good made to Buyer specifications infringed
intellectual property rights of another party.
15. Property; Confidentiality. T he intellectual property embodied in the Goods
is the exclusive property of Seller and its affiliates and Buyer shall not at -
tempt to duplicate it in any way without the written permission of Seller.
Notwithstanding any charges to Buyer for engineering or tooling, all engi-
neering and tooling shall remain the exclusive property of Seller. All infor-
mation and materials supplied by Seller to Buyer relating to t he G oods a re
confidential and proprietary, and Buyer shall limit distribution thereof to its
trusted employees and strictly prevent disclosure to any third party.
16. Miscellaneous. (a) Waiver. No failure or delay by Seller in exercising any
right and no course of dealing between Buyer and Seller shall operate as
a waiver of rights b y Seller. (b) Assignment. B uyer may not assign its rights
hereunder without Seller’s written consent. (c) A mendment. T hese Terms
constitute the entire agreement between Buyer and Seller relating to the
Goods, and no provision may be changed or waived unless in writing
signed by the parties. (d) Severability. If any provision hereof is rendered
ineffective o r i nvalid, such provision s hall n ot invalidate any other p rovision.
(e) Setoff. Buyer shall have no right to set off any amounts against the
amount owing in respect of this invoice. (f) As used herein, “including”
means “including without limitation”.
Certain Precautions on Specifications and Use
1. Suitability of Use. Seller shall not be responsible for conformity with any
standards, codes or regulations which apply to the combination of the
Good in the Buyer’s application or use of the Good. At Buyer ’s request,
Seller will provide applicable third party certification documents identifying
ratings and limitations o f u se w hich apply to the Good. T his information by
itself is not sufficient for a complete determ ination of the suitability of the
Good in combination with the end product, machine, system, or other ap-
plication or u se. T he following are some examples of a pplications for w hich
particular attention must b e given. T his i s n ot i ntended t o b e a n exhaustive
list of all p ossible u ses o f this Good, nor is i t i ntended t o i mply t hat t he u ses
listed may be suitable for this Good:
(i) Outdoor use, uses involving potential chemical contamination or
electrical interference, or conditions or uses not described in this
document.
(ii) Energy control systems, combustion systems, railroad systems,
aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or
government regulations.
(iii)Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to
this Good.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SE -
RIOUS RISK T O L IFE OR PROPERTY WITHOUT E NSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE
RISKS, AND THAT THE SELLER’S PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
2. Programmable Products. S eller shall not be responsible for the user s pro-
gramming of a programmable Good, or any consequence thereof.
3. Performance Data. Performance data given in this catalog is provided as
a guide f or the u ser i n d etermining s uitability and d oes n ot c onstitute a w ar-
ranty. It may represent the result of Seller’s test conditions, and the user
must correlate it to actual application requirements. Actual performance
is subject to the Seller ’s Warranty and Limitations of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are
changed, or when significant construction changes are made. However,
some specifications of the Good may be changed without any notice.
When in doubt, special part numbers may be assigned to fix or establish
key specifications for your application. Please consult with your Sellers
representative at any time to confirm actual specifications of purchased
Good.
5. Errors and Omissions. The information in this catalog has been carefully
checked and is believed to be accurate; however, no responsibility is as -
sumed for clerical, typographical or proofreading errors, or omissions.
21
Switching Power Supply S82H
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
S82Y-H03B S82Y-H03F S82Y-H05B S82Y-H05F S82Y-H05S S82Y-H10F FOR S82H-100W