55A1812 SPECIFICATION CONTROL DRAWING Date Risviston ONE CONDUCTOR CABLE, SHIELDED, JACKETED, NORMAL WEIGHT 03-12-69 Cc The complats requirements for procuring the cable described harain shel coneiet of this it and the wave tn effect of Raychem Speciication S5A. COMPONENT WIRE - SGA0812 SHIELD - SILVER-COATED COPPER JACKET - RADIATION-CROSSLINKED, 7 ae CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C LIFE CYLE: 230 + 3C for 500 hours Meximum continuous conductor temperature LOW TEMPERATURE-COLD BEND: -65 + 3C for 4 hours VOLTAGE RATING: 600 volts (rms) SHIELD COVERAGE: 85% (minimum) ACCELERATED AGING: 300 + 3C for 7 hours THERMAL SHOCK: 300 + 3C for 6 hours BLOCKING: 200 + 3C for 6 hours VOLTAGE WITHSTAND TEST: (After Accelerated Aging, DIELECTRIC WITHSTAND: 1500 voits, 60 Hz Immersion, Life Cycle, Low Temperature-Cold Bend FLAMMABILITY: and Thermal Shock) 1000 volts, 60 Hz, | minute Procedure 1, 3 seconds (maximum); 3 in. (maxdmum); no flaming of facial tiesue PART NUMBER: JACKET COLOR: White preferred The *** in the part numbere above shall be replaced by JACKET ELONGATION AND TENSILE STRENGTH: color code designafore with a dash separating the component Elongation, 50% (minimum) wise color from the jacket color. Tensile Strength, 5000 Ib/in (minimum) Example: AWG 20, white component wire; white jacket JACKET FLAWS: 55A1812-20-6-8 Spark Test, 1000 volta, 60 Hz (rme}, 100% test . Impulse Dielectric Test, 6.0 kV (peek), 100% test Nominal values are not requirements. COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MiL-TD-45t. Raychem Corporation THIS SPECIFICATION SHEET TAKES PRBCEDENCE OVER Pegs 1 of 4 DOCUMENTS REFERENCED HEREIN. RERGRENCED DOC- UMENTS SHALL BE OF THE IGSUE IN EFFECT ON DATE OF INVITATION FOR Bi. 300 Constikution Drive, Meanie Park, Caliosnia 84025 415 381 3003 TW 810 373 1728