Digital Attenuator, 30 dB, 4-Bit
DC - 2.0 GHz
Rev. V1
MAADSS0009
1
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
1
Features
Attenuation 2-dB Steps to 30 dB
High Accuracy
Low Intermodulation Product: +50 dBm IP3
Low DC Power Consumption: 50 µW
Temperature Stability +/-0.15 dB: -40°C to +85°C
Lead-Free SOIC-16 Plastic Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Version of AT-220
Description
M/A-COM’s MAADSS0009 is a 4-bit, 2-dB step
GaAs MMIC digital attenuator in a lead-free SOIC
16-lead surface mount plastic package. The
MAADSS0009 is ideally suited for use where high
accuracy, fast switching, very low power
consumption and low intermodulation products are
required. Typical applications include radio and
cellular equipment, wireless LANs, GPS equipment
and other Gain/Level Control circuits.
The MAADSS0009 is fabricated with a monolithic
GaAs MMIC using a mature 1-micron process. The
process features full chip passivation for increased
performance and reliability.
Ordering Information1
Part Number Package
MAADSS0009 Lead-Free SOIC 16-Lead
MAADSS0009TR-3000 3000 piece reel
1. Reference Application Note M513 for reel size information.
Absolute Maximum Ratings 2,3
Parameter Absolute Maximum
Input Power
50 MHz
500-2000 MHz
+27 dBm
+34 dBm
Control Voltage -8.5 V VC 5V
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
Pin Configuration
Pin No. Function Pin No. Function
1 VC1 9 RF2
2 VC1 10 GND
3 VC2 11 GND
4 VC2 12 GND
5 VC3 13 GND
6 VC3 14 GND
7 VC4 15 GND
8 VC4 16 RF1
Functional Schematic
16 15 14 13 12 11 10 9
1 2 3 4 5 6 7 8
RF1 GND GND GND GND GND GND RF2
16 dB 8 dB 4 dB 2 dB
VC1 VC1 VC2 VC2 VC3 VC3 VC4 VC4
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.