P2 P3
GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25⬚C.
Efficiency: 70% minimum on all models
Hold-up time: 12 msec minimum at 110 VAC input
Line regulation: ±0.5% maximum at full load
Inrush current: 20 amps at 115 VAC or 40 amps at
230 VAC at 25⬚C cold start
Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground
500 VAC from output to ground
Operating temperature: 0⬚C to 70⬚C*
Storage temperature: -40C⬚to +85⬚C
MTBF: 300,000 hours at full load at 25⬚C
ambient; MIL-HDBK-217F
EMI requirements: Meets conduction limits of
a) CISPR 22 (EN 55022) Level B
b) FCC 20780 Level B
Safety requirements: Meets or exceeds:
a) UL 1950
b) CSA C22.2 No. 234
c) IEC 950 (EN60950)
Power Fail Detect: TTL logic high for normal operation
(PFD SIGNAL) and TTL logic low upon loss of input
power. This signal appears at least
1mS prior to the main output dropping
5% below its nominal value. This signal
also provides a minimum delay of 100
mS after the main output is within regulation.
INPUT SPECIFICATIONS
Input voltage: 90 to 264 VAC
Input frequency: 47 to 63 Hz
Input current: 3.6A (rms) for 115 VAC
1.8A (rms) for 230 VAC
OUTPUT SPECIFICATIONS
Output voltage: See Rating Chart
Output current: See Rating Chart
Output power range: See Note #4 on rating chart
Ripple and noise: 2% peak to peak maximum
Overvoltage protection: Provided on output #l only; set at
112-132% of its nominal
output voltage
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature coefficient: All outputs ±0.04%/⬚C maximum
Transient response: Maximum excursion of 4% or
better on all models recovering to
1% of final value within 500us after
a 25% step load change
Cooling: 25 CFM forced air provided on
"C" version; to be provided by user
on "B" version.
* Derate linearly from 100% load at 50°C to 50% load at 70°C
PIN CHART
MECHANICAL SPECIFICATIONS
NOTES:
1. Dimensions shown in inches [mm]
2. Tolerance 0.02 [0.5] maximum
3. Input connector P1 is Beau Inc. P/N
72-5-03C, output connector P2 is
Beau Inc. P/N 72-5-09C. Screws are
#6-32 on 0.375 inch centers.
4. Connector P3 mates with Molex
housing 22-01-1043 and Molex
40445 series crimp terminal.
5. Connector P4 mates with Molex
housing 22-01-1023 and Molex
40445 series crimp terminal.
6. Connector P4 is for DC fan rated
24V/ 0.12A (models IFC200-14,-16,-25)
or 12V/ 0.2A (other models).
7. Weight:
2.8 Lbs. (1.25 Kgs) approx.
for "B" version.
3.3 Lbs. (1.5 Kgs) approx.
for "C" version.
Model PIN 1, 2 3, 4, 5 6 7 8 9 1 2 3 4
IFC200-10, IFC200-12 -SENSE COM OUTPUT OUTPUT OUTPUT +SENSE P.F.D. COM. COM. FAN
IFC200-13, IFC200-14 RET. #1 #1 #1 RET. RET.
IFC200-16, IFC200-18
IFC200-23, IFC200-24 OUTPUT COM. OUTPUT N.C. N.C. N. C. P.F.D. COM. COM. FAN
IFC200-25 #1 RET. #2 RET. RET.
IFC200-30, IFC200-31 OUTPUT COM. OUTPUT OUTPUT N.C. N.C. P.F.D. COM. COM.
IFC200-32, IFC200-33 #1 RET. #2 #3 RET. RET. FAN
IFC200-40, IFC200-41 OUTPUT COM. OUTPUT OUTPUT OUTPUT OUTPUT P.F.D. COM. COM. FAN
IFC200-42, IFC200-44 #1 RET. #2 #3 #4 #4 RET. RET.
IFC200-45 RETURN
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com
P1
1-Line
2-Neutral
3-Ground