USA: 1-888-41-ASTEC Europe (UK): +44(0)1384-842211 Asia (HK): 852-2437-
58
LPS 350
350 Watts
SPECIAL FEATURES
•Active power factor correction
•IEC EN6100-3-2 compliance
•Remote sense
•Power fail and remote inhibit
•Single wire current sharing
•Built-in EMI filter
•Low output ripple
•Supervisory output 5 V and 12 V
•Overvoltage protection
•Overload protection
•Thermal overload protection
•DC power good
•Cover -C
•Optional with fan cover -CF
•Optional end-mounted fan - CEF
ENVIRONMENTAL
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from
50° to 70°C
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full
load and 25°C ambient conditions
ELECTRICAL SPECIFICATIONS
Input
Input range ........................... 85-264 VAC; 120-370 VDC
Frequency ............................ 47-440 Hz
Inrush current....................... 38 A max., cold start @ 25°C
Efficiency..............................75% typical at full load
EMI filter ...............................FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and radiated
VDE 0878 PT3 Class B conducted and
radiated.
Power factor ......................... 0.99 typical
Safety ground
leakage current .................... <0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power...................With cover: 350 W with 30 CFM forced air,
(-C) (-CF) (-CEF)
Adjustment range ................. 2:1 wide ratio
Supervisory outputs ............. 5 V @ 500 mA regulated, 12 V @ 150 mA x2
Hold-up time.........................20 ms @ 350 W load, 115 VAC nominal line
at factory voltage setting
Overload protection..............Short circuit protection on all outputs. Case
overload protected @ 110-145% above
peak rating
Overvoltage protection ......... 5 V output: 5.7-6.7 VDC. Other outputs
10% to 25% above nominal output
Logic Control
Power failure ........................TTL logic signal goes high 50-150 msec
after 5 V output. It goes low at least 4 msec
before loss of regulation
Remote on/off....................... Requires an external contact (N.O or N.C)
to inhibit outputs
DC OK..................................TTL logic goes high 50-150 msec after the
output. It goes low when there is loss of
regulation.
Remote sense ...................... Compensates for 0.5 V lead drop min. Will
operate without remote sense connected.
Reverse connection protected.
SAFETY
VDE 0805/EN60950 (IEC950) 21310-3336-0001
UL UL1950 E186249
CSA CSA 22.2-234 Level 5 LR109492C
NEMKO EN 60950/EMKO-TUE P98102115
(74-sec) 203
BABT EN60950/BS7002 608857, 608858, 609097
CB Certificate and report 5734, 6280, 6281
CE Mark (LVD)
T otal Power
350 Watts
Input V oltages
85 - 264 VAC
120 - 370 VDC
LPS 350 Series
# of Outputs
Single
•LP pg 40-65 05/26/2000, 1:28 PM58