55 SRIES General purpose relays 7 - 10 A Automation for blinds, grilles and shutters Control and management of electric power Shipyards Road / tunnel lighting Hoists and cranes Circuit breakers and switches Control panels Panels for electrical distribution FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. 55 SERIES General purpose relays 7 to 10A 55 SERIES 55.12 General purpose relays For printed circuit mounting 55.13 55.14 Type 55.12 -- 2 CO 10A Type 55.13 -- 3 CO 10A Type 55.14 -- 4 CO 7A A * AC & DC coils * Cadmium Free contacts * Contact material options * RTIII (wash tight) option available * 2 CO 10A * PCB mount * 3 CO 10A * PCB mount * 4 CO 7A * PCB mount For UL ratings see: "General technical information" page V For outline drawing see page 6 Copper side view Copper side view Copper side view 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) 10/20 10/20 7/15 Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage A 250/400 250/400 250/250 VA 2500 2500 1750 Rated load AC15 (230VAC)VA 500 500 350 Rated load AC1 VAC Single phase motor rating (230VAC)kW 0.37 0.37 0.125 Breaking capacity DC1: 30/110/220VA 10/0.5/0.25 10/0.5/0.25 7/0.5/0.25 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi Minimum switching load mW (V/mA) Standard contact material Coil specification Nominal voltage (UN) VAC (50/60Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 VDC Rated power AC/DC Operating range VA (50Hz)/W 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 1.5/1 1.5/1 1.5/1 AC (0.8...1.1)UN (0.8...1.1)UN (0.8...1.1)UN DC (0.8...1.1)UN (0.8...1.1)UN (0.8...1.1)UN Holding voltage AC/DC 0.8UN/0.5UN 0.8UN/0.5UN 0.8UN/0.5UN Must drop-out voltage AC/DC 0.2UN/0.1UN 0.2UN/0.1UN 0.2UN/0.1UN Mechanical life AC/DC cycles 20*106/50*106 20*106/50*106 20*106/50*106 Electrical life at rated load AC1 cycles 200*103 200*103 150*103 ms 10/5 9/5 9/5 kV 4 4 4 Technical data I-2019, www.findernet.com Operate/release time Insulation between coil and contacts (1.2/50s) Dielectric strength between open contacts Ambient temperature range Environmental protection VAC C 1000 1000 1000 -40...+85 -40...+85 -40...+85 RT I RT I RT I Approvals (according to type) 3 55 SERIES 55 SERIES General purpose relays 7 to 10A 55.32 General purpose relays For socket mounting 55.34 Type 55.32 -- 2 CO 10A Type 55.33 -- 3 CO 10A Type 55.34 -- 4 CO 7A * AC & DC coils * Lockable test button and mechanical flag indicator as standard on 2 & 4 pole types * 2 CO 10A * Plug-in 94 series sockets * Integral LED and coil suppression options * 94 series sockets for PCB or 35mm rail * 3 CO 10A * Plug-in 94 series sockets * 4 CO 7A * Plug-in 94 series sockets mounting (EN60715) with Screw, Screwless or Push-in terminals * Coil Indication and EMC suppression modules 99 series and Timer module 86.30 options * Optional alternative mounting adaptors * UL Listing (certain relay/socket combinations) * Cadmium Free contacts * Contact material options * European Patent For UL ratings see: "General technical information" page V For outline drawing see page 6 Contact specification Contact configuration Rated current/Maximum peak current Rated voltage/ Maximum switching voltage Rated load AC1 A VAC VA 2 CO (DPDT) 3 CO (3PDT) 4 CO (4PDT) 10/20 10/20 7/15 250/400 250/400 250/250 2500 2500 1750 Rated load AC15 (230VAC)VA 500 500 350 Single phase motor rating (230VAC)kW 0.37 0.37 0.125 Breaking capacity DC1: 30/110/220VA 10/0.5/0.25 10/0.5/0.25 7/0.5/0.25 300 (5/5) 300 (5/5) 300 (5/5) AgNi AgNi AgNi Minimum switching load mW (V/mA) Standard contact material Coil specification Nominal voltage (UN) VAC (50/60Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 VDC Rated power AC/DC Operating range VA (50Hz)/W 6 - 12 - 24 - 48 - 60 - 110 -125 - 220 1.5/1 1.5/1 1.5/1 AC (0.8...1.1)UN (0.8...1.1)UN (0.8...1.1)UN DC (0.8...1.1)UN (0.8...1.1)UN (0.8...1.1)UN Holding voltage AC/DC 0.8UN/0.5UN 0.8UN/0.5UN 0.8UN/0.5UN Must drop-out voltage AC/DC 0.2UN/0.1UN 0.2UN/0.1UN 0.2UN/0.1UN Mechanical life AC/DC cycles 20*106/50*106 20*106/50*106 20*106/50*106 Electrical life at rated load AC1 cycles 200*10 200*10 150*103 ms 10/5 9/5 9/5 kV 4 4 4 Technical data Operate/release time Insulation between coil and contacts (1.2/50s) Dielectric strength between open contacts Ambient temperature range Environmental protection Approvals (according to type) 4 VAC C 3 3 1000 1000 1000 -40...+85 -40...+85 -40...+85 RT I RT I RT I I-2019, www.findernet.com A 55.33 55 SERIES General purpose relays 7 to 10A 55 SERIES Ordering information Example: 55 series plug-in relay, 4 CO, 12VDC coil, lockable test button and mechanical indicator. 5 5 . 3 A B C D 4 . 9 . 0 1 2 . 0 0 4 0 Series A: Contact material 0 = Standard AgNi 5 = AgNi + Au Type 1 = PCB 3 = Plug-in B: Contact circuit 0 = CO (nPDT) No. of poles 2 = 2 pole, 10A 3 = 3 pole, 10A 4 = 4 pole, 7A Coil version 8 = AC (50/60Hz) 9 = DC Coil voltage See coil specifications Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A B C D 55.32/34 AC - DC AC AC DC 0-5 0-5 0-5 0-5 0 0 0 0 0 2-3-4-5 54 2-4-6-7-8-9 0 0 / 0 DC 0-5 0 74 - 94 / AC - DC 0-5 0 0 0 AC 0-5 0 1-3-5 0 DC AC - DC 0-5 0-5 0 0 1-6-7-8-9 0 0 0-1 55.33 55.12/13/14 A D: Special versions 0 =Standard 1 =Wash tight (RTIII) for 55.12, 55.13 and 55.14 only C: Options 0 =None 1 =Lockable test button 2 =Mechanical indicator 3 =LED (AC) 4 =Lockable test button + mechanical indicator 5 =Lockable test button + LED (AC) 54 =Lockable test button + LED (AC) + mechanical indicator 6* =Double LED (DC non-polarized) 7* =Lockable test button + double LED (DC non-polarized) 74* =Lockable test button + double LED (DC non-polarized) + mechanical indicator 8* =LED + diode (DC, polarity positive to pin A1/13) 9* =Lockable test button + LED + diode (DC, polarity positive to pin A1/13) 94* =Lockable test button + LED + diode (DC, polarity positive to pin A1/13)+ mechanical indicator * Options not available for 220VDC versions. Descriptions: options and special versions C: Option 8, 9, 94 LED + diode (DC, polarity positive to pin A1/13) EUR C: Option 6, 7, 74 Double LED (DC non-polarized) I-2019, www.findernet.com N T E P A EAN 2 EAN T EUR 3 1 Lockable test button and mechanical flag indicator (0010, 0040, 0050, 0054, 0070, 0074, 0090, 0094) OP OP C: Option 3, 5, 54 LED (AC) The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state. Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive. 5 55 SERIES General purpose relays 7 to 10A 55 SERIES Technical data 2 pole - 3 pole 4 pole 230/400 400 2 230 250 2 Basic III 4 2000 Basic III 4 2000 Basic III 4 2000 Basic II 2.5 2000 Micro-disconnection 1000/1.5 Micro-disconnection 1000/1.5 4 1/4 (2 pole), 1/6 (3 pole), 2/4 (4 pole) 15/15 16 1 3 (2 pole) 4 (3 pole) 5 3 (4 pole) Contact specification Resistive load - cos = 1 Inductive load - cos = 0.4 H 55 - Maximum DC1 breaking capacity * When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 100*103 can be expected. 4 pole current limit contacts in series DC voltage (V) 6 Resistive load - cos = 1 Inductive load - cos = 0.4 * In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time of the load will be increased. I-2019, www.findernet.com 2 & 3 pole current limit F 55 - Electrical life (AC) v contact current 4 pole relays Cycles Cycles F 55 - Electrical life (AC) v contact current 2 and 3 pole relays DC breaking current (A) A Insulation according to EN61810-1 Nominal voltage of supply system VAC Rated insulation voltage VAC Pollution degree Insulation between coil and contact set Type of Insulation Overvoltage category Rated impulse voltage kV (1.2/50s) Dielectric strength VAC Insulation between adjacent contacts Type of insulation Overvoltage category Rated impulse voltage kV (1.2/50s) Dielectric strength VAC Insulation between open contacts Type of disconnection Dielectric strength VAC/kV (1.2/50s) Insulation between coil terminals Rated impulse voltage (surge) differential mode (according to EN 61000-4-5) kV(1.2/50s) Other data Bounce time: NO/NC ms Vibration resistance (5...55)Hz: NO/NC g Shock resistance g Power lost to the environment without contact current W with rated current W Recommended distance between relays mounted on PCB mm 55 SERIES General purpose relays 7 to 10A 55 SERIES Coil specifications DC coil data Nominal voltage UN V 6 12 24 48 60 110 125 220 AC coil data Coil code 9.006 9.012 9.024 9.048 9.060 9.110 9.125 9.220 Operating range Umin V 4.8 9.6 19.2 38.4 48 88 100 176 Umax V 6.6 13.2 26.4 52.8 66 121 138 242 Resistance R 40 140 600 2400 4000 12500 17300 54000 R 55 - DC coil operating range v ambient temperature Rated coil consumption I at UN mA 150 86 40 20 15 8.8 7.2 4 Nominal voltage UN V 6 12 24 48 60 110 120 230 240 Coil code 8.006 8.012 8.024 8.048 8.060 8.110 8.120 8.230 8.240 Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 Umax V 6.6 13.2 26.4 52.8 66 121 132 253 264 Resistance R 12 50 190 770 1200 3940 4700 17000 19100 A Rated coil consumption I at UN mA 200 97 53 25 21 12.5 12 6 5.3 R 55 - AC coil operating range v ambient temperature 1 1 2 2 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. Outline drawings Types 55.32/33/34 I-2019, www.findernet.com Types 55.12/13/14 7 55 SERIES 55 SERIES General purpose relays 7 to 10A Accessories Top flange mount adaptor for 55.32, 55.33, 55.34 056.25 A 056.25 056.25 with relay 056.25 Rear flange mount adaptor for 55.32, 55.33, 55.34 056.26 056.26 056.26 with relay 056.26 Top 35mm rail (EN60715) adaptor for 55.32, 55.33, 55.34 056.27 056.25 with relay 056.26 with relay 056.27 056.27 with relay 056.27 with relay I-2019, www.findernet.com 056.27 8 94 SERIES Socket overview for 55 series relays Module 99.02 55 SERIES Socket 94.P3 94.P4 Relay 55.33 55.32 55.34 Description Push-in terminal socket - For fast cable connections - Top terminals - Contacts - Bottom terminals - Coil Mounting Panel or 35mm rail (EN60715) mount Accessories - Coil indication and EMC suppression modules - Jumper link - Timer modules - Plastic retaining and release clip Module 99.02 Socket 94.02 94.03 94.04 Relay 55.32 55.33 55.32 55.34 Description Mounting Screw terminal (Box clamp) socket Panel or 35mm rail - Top terminals - Contacts (EN60715) mount - Bottom terminals - Coil Accessories -C oil indication and EMC suppression modules - J umper link - Timer modules -P lastic retaining and release clip Module 99.02 Socket 94.54 Relay 55.32 55.34 Description Screwless terminal socket - Top terminals - Contacts - Bottom terminals - Coil Mounting Panel or 35mm rail (EN60715) mount Accessories -C oil indication and EMC suppression modules - J umper link - Timer modules -P lastic retaining and release clip Module 99.80 Socket 94.84.2 Relay 55.32 55.34 Description Mounting Screw terminal (Box clamp) socket Panel or 35mm rail (EN60715) mount Accessories -C oil indication and EMC suppression modules - J umper link -P lastic retaining and release clip Module 99.80 Socket 94.92.3 94.94.3 Relay 55.32 55.32 55.34 Description Mounting Screw terminal (Box clamp) socket Panel or 35mm rail - Top terminals - Contacts (EN60715) mount - Bottom terminals - Coil Accessories -C oil indication and EMC suppression modules - J umper link -P lastic retaining and release clip Module 99.01 Socket 94.72 Relay 55.32 94.73 55.33 Mounting Panel or 35mm rail (EN60715) mount 94.74 55.32 55.34 55.32 Description Screw terminal (Plate clamp) socket For 94.82: - 23 mm wide for space saving Accessories -C oil indication and EMC suppression modules -P lastic retaining and release clip 94.P4 See page 10 94.04 See page 12 94.54 See page 13 94.84.2 See page 14 94.94.3 See page 15 94.74 See page 16 94.14 See page 17 I-2019, www.findernet.com 94.22 See page 17 94.34 See page 18 94.82 Module -- -- -- Socket 94.12 94.13 94.14 Relay 55.32 55.33 55.32 55.34 Description PCB socket Mounting PCB mounting Accessories - Metal retaining clip Module Socket Relay Description Mounting Accessories -- -- -- 94.22 94.23 94.24 55.32 55.33 55.32 55.34 Panel mount with solder connections Panel mount on 1mm thick panel - Metal retaining clip Module Socket Relay Description Mounting Accessories -- -- 94.32 94.33 94.34 55.32 55.33 55.32 55.34 Panel mount with solder connections M3 screw fixing - Metal retaining clip A 9 94 SERIES Sockets and accessories for 55 series relays 55 SERIES A 94.P4 Approvals (according to type): Certain relay/socket combinations 094.91.3 060.48 Push-in terminal socket panel or 35mm (EN60715) rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 6-way jumper link Identification tag 2-way jumper link 2-way jumper link Marker tag holder Modules (see table below) Timer modules (see table below) Sheet of marker tags for plastic retaining and release clip 094.91.3 and for marker tag holder 097.00 , 48 tags, 6x12mm for CEMBRE thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C Wire strip length mm Min. wire size for 94.P3 and 94.P4 sockets mm2 AWG Max. wire size for 94.P3 and 94.P4 sockets mm2 AWG R 94.P3 OP EAN EU N T T E P A 94.P3 Blue 55.33 94.P4 Blue 55.32, 55.34 094.71 094.91.3 094.56 095.00.4 094.52.1 097.52 097.00 99.02 86.30 060.48 10A - 250V 2kVAC IP 20 -40...+70 8 solid wire 0.5 21 solid wire 2x1.5 / 1x2.5 2x16 / 1x14 stranded wire 0.5 21 stranded wire 2x1.5 / 1x2.5 2x16 / 1x14 94.P4 094.56 (blue) 10A - 250V 2-way jumper link for 94.P3 and 94.P4 sockets Rated values 094.52.1 10A - 250V EUR 6-way jumper link for 94.P3 and 94.P4 sockets Rated values OP EAN 094.56 I-2019, www.findernet.com 094.52.1 10 94 SERIES Sockets and accessories for 55 series relays 2-way jumper link for 94.P3 and 94.P4 sockets Rated values 55 SERIES 097.52 10A - 250V A 097.52 Marker tag holder for 94.P3 and 94.P4 sockets 097.00 86 series timer modules (12...24)VAC/DC; Bi-function: AI, DI; (0.05s...100h) (110...125)VAC; Bi-function: AI, DI; (0.05s...100h) (230...240)VAC; Bi-function: AI, DI; (0.05s...100h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 097.00 86.30 99.02 Approvals (according to type): 99.02 coil indication and EMC suppression modules for 94.P3 and 94.P4 sockets Diode (+A1, standard polarity) (6...220)VDC 99.02.3.000.00 LED(6...24)VDC/AC 99.02.0.024.59 LED(28...60)VDC/AC 99.02.0.060.59 LED(110...240)VDC/AC 99.02.0.230.59 LED + Diode (+A1, standard polarity) (6...24)VDC 99.02.9.024.99 LED + Diode (+A1, standard polarity) (28...60)VDC 99.02.9.060.99 LED + Diode (+A1, standard polarity) (110...220)VDC 99.02.9.220.99 LED + Varistor (6...24)VDC/AC 99.02.0.024.98 LED + Varistor (28...60)VDC/AC 99.02.0.060.98 LED + Varistor (110...240)VDC/AC 99.02.0.230.98 RC circuit (6...24)VDC/AC 99.02.0.024.09 RC circuit (28...60)VDC/AC 99.02.0.060.09 RC circuit (110...240)VDC/AC 99.02.0.230.09 Residual current by-pass (110...240)VAC 99.02.8.230.07 I-2019, www.findernet.com DC Modules with non-standard polarity (+A2) on request. Approvals (according to type): 11 94 SERIES Sockets and accessories for 55 series relays 55 SERIES A 94.04 Approvals (according to type): Certain relay/socket combinations 094.91.3 Screw terminal (Box clamp) socket panel or 35mm (EN60715) rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 6-way jumper link Identification tag Marker tag holder Modules (see table below) Timer modules (see table below) Sheet of marker tags for plastic retaining and release clip 094.91.3 and for marker tag holder 097.00 , 48 tags, 6x12mm for CEMBRE thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C Screw torque Wire strip length Max. wire size for 94.02/03/04 sockets 060.48 94.02 Blue 55.32 94.02.0 94.03 Black Blue 55.33 94.03.0 94.04 94.04.0 Black Blue Black 55.32, 55.34 094.71 094.91.3 094.91.30 094.91.3 094.91.30 094.91.3 094.91.30 094.06 094.06.0 094.06 094.06.0 094.06 094.06.0 094.00.4 097.00 99.02 86.30 060.48 10A - 250V 2kVAC IP 20 -40...+70 Nm 0.5 mm 8 solid wire mm2 1x6 / 2x2.5 AWG 1x10 / 2x14 stranded wire 1x4 / 2x2.5 1x12 / 2x14 Top terminals R 94.04 OP EAN EU N T T E P A Bottom terminals 094.06 (blue) 10A - 250V 86 series timer modules (12...24)VAC/DC; Bi-function: AI, DI; (0.05s...100h) (110...125)VAC; Bi-function: AI, DI; (0.05s...100h) (230...240)VAC; Bi-function: AI, DI; (0.05s...100h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 094.06.0 (black) EUR 6-way jumper link for 94.02, 94.03 and 94.04 sockets Rated values OP EAN 094.06 99.02 Approvals (according to type): DC Modules with non-standard polarity (+A2) on request. 12 Approvals (according to type): 99.02 coil indication and EMC suppression modules for 94.02, 94.03 and 94.04 sockets Diode (+A1, standard polarity) (6...220)VDC 99.02.3.000.00 LED(6...24)VDC/AC 99.02.0.024.59 LED(28...60)VDC/AC 99.02.0.060.59 LED(110...240)VDC/AC 99.02.0.230.59 LED + Diode (+A1, standard polarity) (6...24)VDC 99.02.9.024.99 LED + Diode (+A1, standard polarity) (28...60)VDC 99.02.9.060.99 LED + Diode (+A1, standard polarity) (110...220)VDC 99.02.9.220.99 LED + Varistor (6...24)VDC/AC 99.02.0.024.98 LED + Varistor (28...60)VDC/AC 99.02.0.060.98 LED + Varistor (110...240)VDC/AC 99.02.0.230.98 RC circuit (6...24)VDC/AC 99.02.0.024.09 RC circuit (28...60)VDC/AC 99.02.0.060.09 RC circuit (110...240)VDC/AC 99.02.0.230.09 Residual current by-pass (110...240)VAC 99.02.8.230.07 I-2019, www.findernet.com 86.30 94 SERIES Sockets and accessories for 55 series relays 55 SERIES Screwless terminal socket 35mm rail (EN60715) mount For relay type Accessories Metal retaining clip Plastic retaining and release clip 6-way jumper link Modules (see table below) Sheet of marker tags for retaining and release clip 094.91.3, plastic, 48 tags, 6x12 mm for CEMBRE thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C Wire strip length mm Max. wire size for 94.54 sockets mm2 AWG 94.54 Approvals (according to type): 094.91.3 94.54 (blue) 55.32, 55.34 A 094.71 094.91.3 094.56 99.02, 86.30 060.48 10A - 250V 2kVAC IP 20 -25...+70 10 solid wire 2x(0.5...1.5) 2x(21...14) stranded wire 2x(0.5...1.5) 2x(21...14) Top terminals 060.48 Sockets + jumper link R Bottom terminals OP EAN EU N T T E P A 094.56 (blue) 10A - 250V 86 series timer modules (12...24)VAC/DC; Bi-function: AI, DI; (0.05s...100h) (110...125)VAC; Bi-function: AI, DI; (0.05s...100h) (230...240)VAC; Bi-function: AI, DI; (0.05s...100h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 EUR 6-way jumper link Rated values OP EAN 094.56 86.30 Approvals (according to type): I-2019, www.findernet.com 99.02 coil indication and EMC suppression modules for 94.54 sockets Diode (+A1, standard polarity) (6...220)VDC LED(6...24)VDC/AC LED(28...60)VDC/AC LED(110...240)VDC/AC 99.02 LED + Diode (+A1, standard polarity) Approvals (according to type): LED + Diode (+A1, standard polarity) LED + Diode (+A1, standard polarity) LED + Varistor LED + Varistor LED + Varistor RC circuit RC circuit RC circuit Residual current by-pass DC Modules with non-standard polarity (+A2) on request. 99.02.3.000.00 99.02.0.024.59 99.02.0.060.59 99.02.0.230.59 (6...24)VDC 99.02.9.024.99 (28...60)VDC (110...220)VDC (6...24)VDC/AC (28...60)VDC/AC (110...240)VDC/AC (6...24)VDC/AC (28...60)VDC/AC (110...240)VDC/AC (110...240)VAC 99.02.9.060.99 99.02.9.220.99 99.02.0.024.98 99.02.0.060.98 99.02.0.230.98 99.02.0.024.09 99.02.0.060.09 99.02.0.230.09 99.02.8.230.07 13 55 SERIES 94 SERIES Sockets and accessories for 55 series relays Screw terminal (Box clamp) socket panel or 35mm (EN60715) rail mount For relay type Accessories Metal retaining clip (supplied with socket - packaging code SMA) Plastic retaining and release clip 6-way jumper link Identification tag Modules (see table below) Sheet of marker tags for retaining and release clip 094.91.3, plastic, 48 tags, 6x12 mm for CEMBRE thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C A 94.84.2 Approvals (according to type): 094.91.3 Screw torque 94.84.2 Blue 55.32, 55.34 094.91.3 094.06 94.84.20 Black 094.71 094.91.30 094.06.0 094.80.3 99.80 060.48 10A - 250V 2kVAC IP 20 -40...+70 Nm 0.5 Wire strip length Max. wire size for 94.84.2 socket mm 7 solid wire mm2 1x6 / 2x2.5 AWG 1x10 / 2x14 060.48 stranded wire 1x4 / 2x2.5 1x12 / 2x14 Top terminals R Bottom terminals OP EAN EU N T T E P A 94.84.2 EUR 6-way jumper link for 94.84.2 socket 094.06 (blue) Rated values 10A - 250V 094.06.0 (black) OP EAN 094.06 99.80 coil indication and EMC suppression modules for 94.84.2 socket Blue* Diode (+A1, standard polarity) (6...220)VDC 99.80.3.000.00 LED(6...24)VDC/AC 99.80.0.024.59 LED(28...60)VDC/AC 99.80.0.060.59 Approvals (according to type): * Modules in Black housing are available on request. Green LED is standard. Red LED available on request. 14 LED(110...240)VDC/AC 99.80.0.230.59 LED + Diode (+A1, standard polarity) (6...24)VDC 99.80.9.024.99 LED + Diode (+A1, standard polarity) (28...60)VDC 99.80.9.060.99 LED + Diode (+A1, standard polarity) (110...220)VDC 99.80.9.220.99 LED + Varistor (6...24)VDC/AC 99.80.0.024.98 LED + Varistor (28...60)VDC/AC 99.80.0.060.98 LED + Varistor (110...240)VDC/AC 99.80.0.230.98 RC circuit (6...24)VDC/AC 99.80.0.024.09 RC circuit (28...60)VDC/AC 99.80.0.060.09 RC circuit (110...240)VDC/AC 99.80.0.230.09 Residual current by-pass (110...240)VAC 99.80.8.230.07 I-2019, www.findernet.com 99.80 94 SERIES Sockets and accessories for 55 series relays 55 SERIES Screw terminal (Box clamp) socket panel or 35mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip 6-way jumper link Identification tag Modules (see table below) Sheet of marker tags for retaining and release clip 094.91.3, plastic, 48 tags, 6x12 mm for CEMBRE thermal transfer printers Technical data Rated values Dielectric strength Protection category Ambient temperature C 94.94.3 Approvals (according to type): 094.91.3 Screw torque 94.92.3 (blue) 55.32 94.92.30 (black) 94.94.3 (blue) 55.32, 55.34 094.71 094.91.30 094.91.3 094.06.0 094.06 094.80.3 99.80 094.91.3 094.06 94.94.30 (black) A 094.91.30 094.06.0 060.48 10A - 250V 2kVAC IP 20 -25...+70 Nm 0.5 Wire strip length Max. wire size for 94.92.3 and 94.94.3 sockets mm 8 solid wire mm2 1x6 / 2x2.5 AWG 1x10 / 2x14 060.48 stranded wire 1x4 / 2x2.5 1x12 / 2x14 Top terminals R Bottom terminals OP EAN EU N T T E P A 94.94.3 6-way jumper link for 94.92.3 and 94.94.3 sockets 094.06 (blue) Rated values 10A - 250V 094.06.0 (black) EUR OP EAN 094.06 99.80 coil indication and EMC suppression modules for 94.92.3 and 94.94.3 sockets Blue* Diode (+A1, standard polarity) (6...220)VDC 99.80.3.000.00 LED(6...24)VDC/AC 99.80.0.024.59 LED(28...60)VDC/AC 99.80.0.060.59 99.80 Approvals (according to type): LED(110...240)VDC/AC 99.80.0.230.59 LED + Diode (+A1, standard polarity) (6...24)VDC 99.80.9.024.99 LED + Diode (+A1, standard polarity) (28...60)VDC 99.80.9.060.99 LED + Diode (+A1, standard polarity) (110...220)VDC 99.80.9.220.99 I-2019, www.findernet.com LED + Varistor * Modules in Black LED + Varistor housing are available on LED + Varistor request. RC circuit Green LED is standard. RC circuit Red LED available on RC circuit request. Residual current by-pass (6...24)VDC/AC 99.80.0.024.98 (28...60)VDC/AC 99.80.0.060.98 (110...240)VDC/AC 99.80.0.230.98 (6...24)VDC/AC 99.80.0.024.09 (28...60)VDC/AC 99.80.0.060.09 (110...240)VDC/AC 99.80.0.230.09 (110...240)VAC 99.80.8.230.07 15 55 SERIES 94 SERIES Sockets and accessories for 55 series relays A 94.74 Approvals (according to type): 94.82 Approvals (according to type): Screw terminal (Plate clamp) socket panel or 35mm (EN60715) rail mount For relay type Accessories Metal retaining clip (supplied with socket - packaging code SMA) Modules (see table below) Screw terminal (Plate clamp) socket: panel or 35mm rail mount For relay type Accessories Metal retaining clip (supplied with socket - packaging code SMA) Modules (see table below) Technical data Rated values Dielectric strength Protection category Ambient temperature C Screw torque 94.72 Blue 55.32 94.72.0 94.73 Black Blue 55.33 94.82 (blue) 55.32 94.73.0 94.74 94.74.0 Black Blue Black 55.32, 55.34 094.71 99.01 94.82.0 (black) 55.32 094.71 99.01 10A - 250V 2kVAC IP 20 -40...+70 Nm 0.5 Wire strip length Max. wire size for 94.72/73/74 and 94.82 sockets 94.72 mm 8 (94.72/73/74) solid wire mm2 1x2.5 / 2x1.5 AWG 1x14 / 2x16 9 (94.82) stranded wire 1x2.5 / 2x1.5 1x14 / 2x16 94.73 94.74 Top terminals Bottom terminals 99.01 coil indication and EMC suppression modules for 94.72, 94.73, 94.74 and 94.82 sockets Blue* Diode (+A1, standard polarity) (6...220)VDC 99.01.3.000.00 Diode (+A2, non standard polarity) (6...220)VDC 99.01.3.000.00 LED(6...24)VDC/AC 99.01.0.024.59 LED(28...60)VDC/AC 99.01.0.060.59 99.01 LED(110...240)VDC/AC 99.01.0.230.59 Approvals LED + Diode (+A1, standard polarity) (6...24)VDC 99.01.9.024.99 (according to type): LED + Diode (+A1, standard polarity) (28...60)VDC 99.01.9.060.99 LED + Diode (+A1, standard polarity) (110...220)VDC 99.01.9.220.99 LED + Diode (+A2, non standard polarity) (6...24)VDC 99.01.9.024.99 LED + Diode (+A2, non standard polarity) (28...60)VDC 99.01.9.060.99 * Modules in Black LED + Diode (+A2, non standard polarity) (110...220)VDC 99.01.9.220.99 housing are available on LED + Varistor (6...24)VDC/AC 99.01.0.024.98 request. LED + Varistor (28...60)VDC/AC 99.01.0.060.98 Green LED is standard. LED + Varistor (110...240)VDC/AC 99.01.0.230.98 Red LED available on RC circuit (6...24)VDC/AC 99.01.0.024.09 request. RC circuit (28...60)VDC/AC 99.01.0.060.09 RC circuit (110...240)VDC/AC 99.01.0.230.09 Residual current by-pass (110...240)VAC 99.01.8.230.07 16 I-2019, www.findernet.com 94.82 94 SERIES Sockets and accessories for 55 series relays 94.14 Approvals (according to type): 55 SERIES PCB socket 94.12 Blue 94.12.0 94.13 Black Blue For relay type 55.32 55.33 94.13.0 94.14 Black Blue 94.14.0 Black 55.32, 55.34 A Accessories Metal retaining clip (supplied with socket - packaging code SMA) 094.51 Technical data Rated values 10A - 250V Dielectric strength 2kVAC Ambient temperature C -40...+70 Copper side view 94.12 94.22 Approvals (according to type): 94.13 94.14 Panel mount solder socket 1mm thick panel 94.22 Blue 94.22.0 94.23 Black Blue For relay type 55.32 55.33 94.23.0 94.24 Black Blue 94.24.0 Black 55.32, 55.34 Accessories Metal retaining clip (supplied with socket - packaging code SMA) 094.51 Technical data Rated values Dielectric strength 2kVAC C -40...+70 I-2019, www.findernet.com Ambient temperature 10A - 250V 17 55 SERIES 94.34 Approvals (according to type): Panel mount socket M3 screw fixing - solder connections 94.32 Blue 94.32.0 94.33 Black Blue For relay type 55.32 55.33 94.33.0 94.34 Black Blue 94.34.0 Black 55.32, 55.34 Accessories Metal retaining clip (supplied with socket - packaging code SMA) 094.51 Technical data Rated values 10A - 250V Dielectric strength 2kVAC Ambient temperature C -40...+70 Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: 9 4 . P 4 S P A A Standard packaging SM Metal retaining clip SP Plastic retaining clip I-2019, www.findernet.com A 94 SERIES Sockets and accessories for 55 series relays 18 Please see general technical information