AC/DC Converter
www.recom-power.com REV.: 6/2020 PA-1
Features
Regulated
Converter
Ultra-wide input range 85-528VAC
OVC
III
input rating without additional fuses
Operating temperature range: -40°C to +80°C
Overvoltage and overcurrent protected
Class
II
installations (without FG)
EMC compliant without external components
No load power consumption <0.5W RAC05-K/480
5 Watt
2‘‘ x 1‘
Single Output
ERP
compliant
R
E
C
O
M
C
O
N
V
E
R
T
E
R
S
C
O
M
P
L
I
A
N
T
P
R
O
D
U
C
T
S
REACH
REACH
compliant
compliant
Description
The RAC05-K/480 series of 5 watt AC/DC units are specially designed for harsh industrial and outdoor
mains conditions. These PCB-mount power supplies are rated to OVC
III
conditions from 100-480VAC
nominal input lines with phase-to-phase or single phase operation without any external components
needed. The modules support an operating temperature range from -40°C to +80°C and come with
fully protected outputs as well as EMC Class B compliance. All these features make them an ideal fit for
integration into smart grid, renewable energy, smart metering and IoT applications.
R
E
C
O
M
C
O
N
V
E
R
T
E
R
S
C
O
M
P
L
I
A
N
T
P
R
O
D
U
C
T
S
RoHS
RoHS
2
2
+
+
compliant
compliant
10 from 10
10 from 10
IEC/EN62368-1 compliant
UL61010-1 certified
CSA C22.2 No. 61010-1 certified
IEC/EN61010-1 certified
IEC/EN61204-3 compliant
EN55032 compliant
EN55014-1 compliant
EN55014-2 compliant
EN55024 compliant
EN61000 compliant
CB Report
Selection Guide
Part Input Output Output Efficiency Max. Capacitive
Number Voltage Range Voltage Current typ (1) Load
(2)
[VAC] [VDC] [mA] [%] [µF]
RAC05-05SK/480 85-528 5 1000 63 10000
RAC05-12SK/480 85-528 12 420 65 1200
RAC05-15SK/480 85-528 15 330 60 1000
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
Model Numbering
Ordering Examples:
RAC05-05SK/480 5Vout Single Output
RAC05-12SK/480 12Vout Single Output
Single
nom. Output Power
Output Voltage
RAC05-__ _K/480
5003727
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Internal Input Filter Pi type
Input Voltage Range (3,4) nom. Vin= 480VAC 85VAC
120VDC
480VAC 528VAC
745VDC
Input Current 400VAC
480VAC
40mA
35mA
Inrush Current cold start at +25°C 400VAC
480VAC
18A
20A
No load Power Consumption 500mW
Input Frequency Range AC Input 47Hz 63Hz
Minimum Load 0%
continued on next page
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Y
E
A
R
w
a
r
r
a
n
t
y
3
www.recom-power.com REV.: 6/2020 PA-2
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/480
Series
Parameter Condition Min. Typ. Max.
Power Factor 400VAC/480VAC 0.45
Start-up Time 25ms
Rise Time 20ms
Hold-up Time 400VAC
480VAC
150ms
200ms
Internal Operating Frequency 130kHz
Output Ripple and Noise (5) 20MHz BW 400VAC
480VAC 50mVp-p
Notes:
Note3: The products were submitted for safety files at AC-Input operation
Note4: Refer to „Line Derating“
Note5: Measurements are made with a 0.1μF MLCC & 10μF E-cap in parallel across output. (low ESR)
Efficiency vs. Load
RAC05-05SK/480
RAC05-15SK/480
RAC05-12SK/480
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
230VAC
400VAC
480VAC
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
230VAC
400VAC
480VAC
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
230VAC
400VAC
480VAC
www.recom-power.com REV.: 6/2020 PA-3
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/480
Series
REGULATIONS
Parameter Condition Value
Output Accuracy ±1.0% typ.
Line Regulation ±0.5% typ.
Load Regulation 10% to 100% load 1.0% typ.
Transient Response 25% load step change
recovery time
4.0% max.
500μs typ.
PROTECTIONS
Parameter
Type
Value
Input Fuse (6) internal fusible resistor 5W
Short Circuit Protection (SCP) below 100mWhiccup, automatic restart
Over Voltage Protection (OVP) 150% - 195%, hiccup mode
Over Voltage Category OVC
III
Over Current Protection (OCP) 150% - 195%, hiccup mode
Class of Equipment Class
II
continued on next page
Deviation at 400/480VAC
1
0.5
0
-1.0
-0.5
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
1
0.5
0
-0.5
-1
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
1
0.5
0
-0.5
-1
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
RAC05-05SK/480 RAC05-12SK/480
RAC05-15SK/480
www.recom-power.com REV.: 6/2020 PA-4
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/480
Series
Parameter Type Value
Isolation Voltage (7) I/P to O/P
I/P to case and O/P to case tested for 1 minute 4kVAC
Isolation Resistance 1GW min.
Isolation Capacitance 100pF max.
Insulation Grade reinforced
Leakage Current 25μA max.
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range @ natural convection 0.1m/s full load -40°C to +60°C
refer to „Derating Graph“ -40°C to +80°C
Maximum Case Temperature +100°C
Temperature Coefficient 0.05%/K
Thermal Impedance 0.1m/s, horizontal (vertical) 16K/W
Operating Altitude 3000m
Operating Humidity non-condensing 5% - 95% RH max.
Vibration according to MIL-STD-202G
10-500Hz, 2G 10min./1cycle, period 60min.
each along x,y,z axes
Design Lifetime +25°C
+60°C
105 x 103 hours
40 x 103 hours
MTBF according to MIL-HDBK-
217F, G.B.
+25°C
+40°C
>1726 x 103 hours
>1585 x 103 hours
-40 -20 0 20 40 60 80 100 120
100
80
60
40
90
70
50
30
20
10
0
Ambient Temperature [°C]
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
80
60
40
90
70
50
30
20
10
0
Input Voltage [VAC]
85 90 528
Line Derating
Notes:
Note6: Refer to local safety regulations if input over-current protection is also required. Recommended fuse type: slow blow
This product can also be used with a DC supply if an appropriately rated external fuse is used. Recom recommends a 600mA, 1kVDC fuse
with a 10kA interrupting rating.
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Protection Circuit (3,6)
-Vout
+Vout
+V
out
-V
out
(L)
DC
source
(N)
F
F
+
-
www.recom-power.com REV.: 6/2020 PA-5
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/480
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Audio/video, information and communication technology equipment.
Safety requirements (LVD)
IEC62368-1:2014 2nd Edition
EN62368-1:2014 + A11:2017
Safety requirements for electrical equipment for measurement, control and labora-
tory use - Part 1: General requirements 190415122GZU-001 UL61010-1, 3rd Edition 2012
CSA C22.2 No. 61010-1, 3rd Edition:2012
Safety requirements for electrical equipment for measurement, control and labora-
tory use - Part 1: General requirements 190415125GZU-001
EN61010-1:2010
Safety requirements for electrical equipment for measurement, control and labora-
tory use - Part 1: General requirements
(CB Scheme)
IEC61010-1:2010 + A1:2016 3rd Edition
EAC RU-AT.03.67361 TP TC 004/020, 2011
RoHS2 RoHS-2011/65/EU + AM-2015/863
EMC Compliance Condition Standard / Criterion
Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility
LCS180508025BE
IEC/EN61204-3:2018, Class B
Electromagnetic compatibility of multimedia equipment – Emission Requirements (8) EN55032:2015, Class B
Electromagnetic compatibility of household appliances, electric tools and similar
apparatus - Emission Requirements EN55014-1:2006+A2:2011
Information technology equipment - Immunity characteristics -
Limits and methods of measurement EN55024:2010+A1:2015
Electromagnetic compatibility of household appliances, electric tools and similar
apparatus - Immunity Requirements EN55014-2:2015
ESD Electrostatic discharge immunity test ±8, 4, 2kV Air; ±4, 2kV Contact EN61000-4-2: 2009, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test
10V/m, 80MHz-1GHz
3V/m, 1.5GHz-2GHz
1V/m, 2GHz-2.7GHz
EN61000-4-3: 2006 + A1:2009, Criteria A
Fast Transient and Burst Immunity AC In Port: ±2.0kV
DC Out Port: ±2.0kV EN61000-4-4:2012, Criteria B
Surge Immunity AC IN Port: L-N ±1.0kV
DC Out Port: ±0.5kV EN61000-4-5:2014+A1:2017, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields 10Vrms EN61000-4-6:2014, Criteria A
Power Magnetic Field Immunity 50Hz, 30A/m EN61000-4-8:2010, Criteria A
Voltage Dips and Interruptions
Voltage Dips 100%
Voltage Dips 60%
Voltage Dips 30%
Voltage Dips 20%
Voltage Interruptions > 95%
EN61000-4-11:2004+A1:2017, Criteria B
EN61000-4-11:2004+A1:2017, Criteria C
EN61000-4-11:2004+A1:2017, Criteria C
EN61000-4-11:2004+A1:2017, Criteria C
EN61000-4-11:2004+A1:2017, Criteria C
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case
potting
PCB
baseplate
black plastic, (UL94V-0)
silicone, (UL94V-0)
FR4, (UL94V-0)
plastic, (UL94V-0)
Dimension (LxWxH) 52.5 x 27.4 x 23.0mm
Weight 58g typ.
continued on next page
Notes:
Note8: If output is connected to GND, please contact RECOM tech support for advice
www.recom-power.com REV.: 6/2020 PA-6
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/480
Series
INSTALLATION AND APPLICATION
Phase to Phase Application Standard L to N Application
L1 L2 L3
IC1
-VOUT
+VOUT
VACIN (N)
VACIN (L)
L N
IC1
-VOUT
+VOUT
VACIN (L)
VACIN (N)
Phase Redundancy B6U Application
L1 L2 L3
IC1
D
3
D
4
D
5
D
2
D
1
D
0
-VOUT
+VOUT
VACIN (L)
VACIN (N)
Bottom View
20.32
52.5
51.5 26.3
27.423.0
6.0 ±1.0
Ø1.0 +0.15/-0.05
10.16
3.50
3.39 2.54
2. 54
18x2.54= 45.72
embossed logo
Top View
2
1
1
2
4
4
33
Dimension Drawing (mm)
Recommended Footprint Details
Pin Connections
Pin # Single
1 VAC in (N) (L2)
2 VAC in (L) (L1)
3 -Vout
4 +Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
www.recom-power.com REV.: 6/2020 PA-7
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/480
Series
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) tube 490.0 x 56.0 x 40.0mm
Packaging Quantity 15pcs
Storage Temperature Range -40°C to +85°C
Storage Humidity non-condensing 20% to 90% RH max.