Specifications (Core Operating Area)
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2% typ. / 1.4% max.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
9V, 12V, 15V, 24V output types 10% max.
Output Ripple and Noise (20MHz limited) 75mVp-p max.
Operating Frequency 50kHz min. / 100kHz typ. / 105kHz max.
Efficiency at Full Load 70% min. / 75% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 1000VDC
(rated for 1 minute**) 500VAC / 60Hz
Isolation Voltage H-Suffix (tested for 1 second) 2000VDC
H-Suffix (rated for 1 minute**) 1000VAC / 60Hz
Isolation Capacitance 30pF min. / 95pF max.
Isolation Resistance 10 GΩmin.
Short Circuit Protection 1 Second
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 1.9g
Packing Quantity 39 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 955 x 103 hours
(+85°C) using MIL-HDBK 217F 132 x 103 hours
Certifications
EN General Safety Report: SPCLVD1109103 EN60950-1:2006 + A12:2011
1.25 Watt
DIP8
Single Output
Derating-Graph
(Ambient Temperature)
●Custom Solutions Available
●1kVDC & 2kVDC Isolation
●No Extern. Components Required
●UL94V-0 Package Material
●No Heatsink Required
●Efficiency to 85%
Features
Unregulated
Converters
Detailed information
page 266
}
Refer to Application Notes
Description The RN series of compact 1.25W single output converters are especially useful when more
than 1W of power is required, but there are space restrictions than make a 2W converter
unsuitable. The converter series feature an industrial ambient temperature operating range of
-40°C to +85°C without derating and up to 100°C ambient temperature with derating.
Options include 1kVDC or 2kVDC isolation and continuous short circuit protection (/P).
Part Input Output Output Efficiency Max.
Number Voltage Voltage Current Capacitive
DIP6 (2kV) (VDC) (VDC) (mA) (%) Load(1)
RN-xx3.3S (H) 3.3, 5, 9, 12, 15, 24 3.3 378 70 2200μF
RN-xx05S (H) 3.3, 5, 9, 12, 15, 24 5 250 70-72 1000μF
RN-xx07S (H) 3.3, 5, 9, 12, 15, 24 7 180 72-75 1000μF
RN-xx09S (H) 3.3, 5, 9, 12, 15, 24 9 140 75-80 1000μF
RN-xx12S (H) 3.3, 5, 9, 12, 15, 24 12 104 79-82 470μF
RN-xx15S (H) 3.3, 5, 9, 12, 15, 24 15 84 80-84 470μF
RN-xx24S (H) 3.3, 5, 9, 12, 15, 24 24 52 80-85 220μF
x = Input Voltage (other input and output voltage combinations available on request)
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RN-0505S/P, RN-0505S/HP
RoHS
2011/65/EU
6/6
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
REV: 0/2015 E-81www.recom-power.com