Setpoint Accuracy ±1%
Line Regulation Vin Min. - Vin Max., Iout Rated 0.2% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom. 0.5% Vout
Minimum Output Current 10 %
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500 ms
Voltage Trim Range ±10%
Short Circuit / Overcurrent Protection Shutdown / Hiccup
Current Limit Threshold Range, % of Iout Rated 110 - 140%
OVP Trip Range 115 - 140% Vout Nom.
OVP Type Second Control Loop, Self-Recovering
20W standard package
100°C case operation
• 3.3V output available
• Open-frame or encapsulated
87% efficiency at 5V
Wide range input
1500V isolation
Short circuit protection
Description
Features
Voltage Range
24 VDC Nominal 16 - 36 VDC
48 VDC Nominal 36 - 72 VDC
Input Undervoltage Lockout <34V or <17V
UVLO Hysteresis 1V Nom.
Reflected Ripple 25 mA
Input Reverse Voltage Protection Shunt Diode
Input
Output
General
Turn-On Time 10 ms
Remote Shutdown Positive Logic
Switching Frequency 300 kHz Open Frame / 450 kHz Cased
Isolation
Input - Output 1500 VDC
Input - Case (24 Vin Units) 500 VDC
Output - Case (48 Vin Units) 500 VDC
Temperature Coefficient 0.03%/°C
Case Temperature
Operating Range -40 To +100°C
Storage Range -40 To +125°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
MTBF(Bellcore TR-NWT-000332) 1.9 x 106hrs
Safety UL, CSA, EN60950
Weight (approx.) 1.2 oz
Notes
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
IES DC/DC converters provide up to 20 watts of output
power in an industry-standard package. With 87%
efficiency and a maximum case temperature of 100°C, the
IES is well suited for the most demanding telecom,
networking, and industrial applications. The IES features
1500 VDC isolation, short circuit, and overtemperature
protection.
Technical Specifications
IES020YG-A
40
45
50
55
60
65
70
75
80
85
10 20 30 40 50 60 70 80 90 100
LOAD %
EFF. (18v)
EFF. (24v)
EFF. (36v)
Efficiency vs. Load (48V Input)
Efficiency vs. Load (24V Input)
IES020ZG-A
40
45
50
55
60
65
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
IES DC/DC Series Data Sheet
Page 1 of 3
REV. SEP 12, 2003
MODEL INPUT VOLTAGE INPUT VOLTAGE MAXIMUM INPUT OUTPUT RATED OUTPUT RIPPLE & NOISE TYPICAL
(VOLTS) RANGE (VOLTS) CURRENT (AMPS)* VOLTAGE (VOLTS) CURRENT (AMPS) pk-pk (mV) EFFICIENCY**
IES020YG-A 24 16-36 1.23 5.0 4.0 75 87%
IES013ZE-A 48 36-72 0.45 3.3 4.0 150 83%
IES020ZG-A 48 36-72 0.65 5.0 4.0 75 87%
NOTES: * Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
9
8
7
6
5
4
3
2
1
2.00"
(50.8mm)
(25.4mm)
1.00"
.200(5.08)
.400(10.16)
.600(15.24)
0
-0.10"
(-2.5mm)
0
1.800"
(45.7mm)
-0.20"(-5.1mm)
0.100"(2.5mm)
0.300"(7.6mm)
0.500"(12.7mm)
0.700"(17.8mm)
-0.100"(-2.5mm)
(10.2mm)
0.40"
(4.6mm)
0.18"
(1.0mm)
DIA 0.040"
OPEN FRAME
(13.2mm)
0.52"
(4.6mm)
0.18" MIN.
(1.0mm)
DIA 0.040"
ENCAPSULATED
Mechanical Drawing
Thermal Impedance
Note:
Thermal impedance data is dependent on many environmental
factors. The exact thermal performance should be validated for
specific application.
Encapsulated Open Frame
Modules Modules
Natural Convection 15.4 °C/W 14.9 °C/W
100 LFM 12.2 °C/W 11.3 °C/W
200 LFM 9.3 °C/W 8.3 °C/W
300 LFM 7.4 °C/W 6.8 °C/W
400 LFM 6.4 °C/W 5.4 °C/W
Pin Function
1+V
in
2-V
in
3 No Pin
4 Shutdown
5+V
out
6-V
out
7 Trim
8 No Pin
9 No Pin
Tolerances
Inches: (Millimeters)
.XX ± 0.020 .X ± 0.5
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
Case:
+ 0.04, - 0.00 + 1.0, - 0.00
(Dimensions as listed unless otherwise
specified.)
(Contact Factory)
IES DC/DC Series Data Sheet
Page 2 of 3
REV. SEP 12, 2003
Model Selection
OPTIONS
Page 3 of 3
REV. SEP 12, 2003
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Pin Length and Heatsink Options Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length 8 All Leaded Models
0.150" (3.8mm) Pin Length 9 All Leaded Models
0.24" (6.1mm) Horizontal Heatsink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heatsink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heatsink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heatsink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heatsink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heatsink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.