DG189/190/191
Vishay Siliconix
Document Number: 70034
S-52880—Rev. C, 28-Apr-97 www.vishay.com
3
SPECIFICATIONSa FOR DG189
Test Conditions
Unless Specified A Suffix
–55 to 125_CB Suffix
–25 to 85_C
Parameter Symbol V+ = 15 V, V– = –15 V, VL = 5 V
VR = 0 V, VIN = 0.8 V or 2 VfTempbTypcMindMaxdMindMaxdUnit
Analog Switch
Analog Signal RangeeVANALOG Full –7.5 15 –7.5 15 V
Drain-Source
On-Resistance rDS(on) IS = –10 mA, VD = –7.5 V Room
Full 7.5 10
20 15
25
Source Off VS = "10 V, VD = #10 V
V+ = 10 V, V– = –20 V Room
Hot 0.05 10
1000 15
300
Source Off
Leakage Current IS(off) VS = "7.5 V, VD = #7.5 V Room
Hot 0.05 10
1000 15
300
Drain Off VS = "10 V, VD = #10 V
V+ = 10 V, V– = –20 V Room
Hot 0.04 10
1000 15
300 nA
Drain Off
Leakage Current ID(off) VS = "7.5 V, VD = #7.5 V Room
Hot 0.03 10
1000 15
300
Channel On
Leakage Current ID(on) VD = VS = "7.5 V Room
Hot –0.1 –2
–200 –10
–200
Saturation Drain Current IDSS 2 ms Pulse Duration Room 300 mA
Digital Input
Input Current with
Input Voltage High IINH VIN = 5 V Room
Hot <0.01 10
20 10
20
Input Current with
Input Voltage Low IINL VIN = 0 V Full –30 –250 –250
A
Dynamic Characteristics
Turn-On Time ton Room 240 400 425
Turn-Off Time toff See Switching Time Test Circuit Room 140 200 225 ns
Source-Off Capacitance CS(off) VS = –5 V, ID = 0 Room 21
Drain-Off Capacitance CD(off) f = 1 MHz VD = –5 V, IS = 0 Room 17 pF
Channel-On Capacitance CD(on) VD = VS = 0 V Room 17
Off Isolation OIRR f = 1 MHz, RL = 75 Room >55 dB
Power Supplies
Positive Supply Current I+ Room 0.6 1.5 1.5
Negative Supply Current I–Room –2.7 –5–5
Logic Supply Current ILVIN = 0 V, or 5 V Room 3.1 4.5 4.5 mA
Reference Supply Current IRRoom –1–2–2
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.