90.03
90.26
90.23
90.83.3
90.21
7
90 Series - Socket overview for 60 series relays
See page 8
See page 9
Module Socket Relay Description Mounting Accessories
90.22 60.12 Screw terminal (Box clamp) socket Panel or 35 mm rail -
Metal retaining clip
90.23 60.13 (EN 60715) mount
See page 10
Module Socket Relay Description Mounting Accessories
90.82.3 60.12 Screw terminal (Box clamp) socket Panel or 35 mm rail -
Metal retaining clip
90.83.3 60.13 (EN 60715) mount
See page 10
Module Socket Relay Description Mounting Accessories
90.26 60.12
Screw terminal (Plate clamp) socket
Panel or 35 mm rail - Metal retaining clip
90.27 60.13 (EN 60715) mount
See page 11
Module Socket Relay Description Mounting Accessories
90.12 60.12 Flange mount solder socket M3 screw fixing
90.13 60.13
See page 11
Module Socket Relay Description Mounting Accessories
90.14 60.12 PCB socket PCB —
90.14.1 60.12
90.15 60.13
90.15.1 60.13
See page 12
Module Socket Relay Description Mounting Accessories
99.02 90.02 60.12 Screw terminal (Box clamp) socket Panel or 35 mm rail - Coil indication and EMC
90.03 60.13 Double A1 terminal (EN 60715) mount suppression modules
- Jumper link
- Timer modules
- Metal retaining clip
Module Socket Relay Description Mounting Accessories
99.01 90.20 60.12 Screw terminal (Box clamp) socket Panel or 35 mm rail - Coil indication and EMC
90.21 60.13 (EN 60715) mount suppression modules
- Metal retaining clip
90.12
90.15
90.03
90 Series - Sockets and accessories for 60 series relays
Approvals
(according to type):
Screw terminal (Box clamp) socket 90.02 90.02.0 90.03 90.03.0
panel or 35 mm rail (EN 60715) mount Blue Black Blue Black
For relay type 60.12 60.13
Accessories
Metal retaining clip 090.33
6-way jumper link 090.06
Identification tag 090.00.2
Modules (see table below) 99.02
Timer modules (see table below) 86.00, 86.30
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40...+70
Screw torque Nm 0.6
Wire strip length mm 10
Max. wire size for 90.02 and 90.03 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
6-way jumper link for 90.02 and 90.03 sockets 090.06 (blue)
Rated values 10 A - 250 V
DC Modules with
non-standard polarity
(+A2) on request.
99.02 coil indication and EMC suppression modules for 90.02 and 90.03 sockets
Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00
LED (6...24)V DC/AC 99.02.0.024.59
LED (28...60)V DC/AC 99.02.0.060.59
LED (110...240)V DC/AC 99.02.0.230.59
LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99
LED + Varistor (6...24)V DC/AC 99.02.0.024.98
LED + Varistor (28...60)V DC/AC 99.02.0.060.98
LED + Varistor (110...240)V DC/AC 99.02.0.230.98
RC circuit (6...24)V DC/AC 99.02.0.024.09
RC circuit (28...60)V DC/AC 99.02.0.060.09
RC circuit (110...240)V DC/AC 99.02.0.230.09
Residual current by-pass (110...240)V AC 99.02.8.230.07
86 series timer modules
Multi-voltage: (12…240)V AC/DC;
Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05 s…100 h) 86.00.0.240.0000
(12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.0.024.0000
(110...125)V AC; Bi-function: AI, DI; (0.05s…100h) 86.30.8.120.0000
(230...240)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.8.240.0000
Approvals
(according to type):
Approvals
(according to type):
Approvals (according to type):
8
Certain relay/socket
combinations
090.06
86.00
99.02
86.30
90.21
Approvals
(according to type):
Screw terminal (Box clamp) socket 90.20 90.20.0 90.21 90.21.0
panel or 35 mm rail (EN 60715) mount Blue Black Blue Black
For relay type 60.12 60.13
Accessories
Metal retaining clip (supplied with socket - packaging code SMA)
090.33
Modules (see table below) 99.01
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.5
Wire strip length mm 10
Max. wire size for 90.20 and 90.21 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x6 / 2x2.5
AWG 1x10 / 2x14 1x10 / 2x14
90 Series - Sockets and accessories for 60 series relays
99.01 coil indication and EMC suppression modules for 90.20 and 90.21 sockets
Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.01.3.000.00
Diode (+A2, non-standard polarity) (6...220)V DC 99.01.2.000.00
LED (6...24)V DC/AC 99.01.0.024.59
LED (28...60)V DC/AC 99.01.0.060.59
LED (110...240)V DC/AC 99.01.0.230.59
LED + Diode (+A1, standard polarity) (6...24)V DC 99.01.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.01.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.01.9.220.99
LED + Diode (+A2, non-standard polarity) (6...24)V DC 99.01.9.024.79
LED + Diode (+A2, non-standard polarity) (28...60)V DC 99.01.9.060.79
LED + Diode (+A2, non-standard polarity) (110...220)V DC 99.01.9.220.79
LED + Varistor (6...24)V DC/AC 99.01.0.024.98
LED + Varistor (28...60)V DC/AC 99.01.0.060.98
LED + Varistor (110...240)V DC/AC 99.01.0.230.98
RC circuit (6...24)V DC/AC 99.01.0.024.09
RC circuit (28...60)V DC/AC 99.01.0.060.09
RC circuit (110...240)V DC/AC 99.01.0.230.09
Residual current by-pass (110...240)V AC 99.01.8.230.07
*Modules in Black
housing are
available on request.
Green LED is standard.
Red LED available on
request.
9
99.01
90.20 90.21
Approvals
(according to type):
90.2390.22
90.82.3 90.83.3
90.23
90.83.3
10
Approvals
(according to type):
Screw (Box clamp) terminal socket 90.22 90.23
panel or 35 mm rail (EN
60715
) mount Blue Blue
For relay type 60.12 60.13
Accessories
Metal retaining clip (supplied with socket - packaging code SMA)
090.33
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.5
Wire strip length mm 7
Max wire size for 90.22 and 90.23 sockets solid wire stranded wire
mm21x6 / 2x2.5 1x6 / 2x2.5
AWG 1x10 / 2x14 1x10 / 2x14
Approvals
(according to type):
90 Series - Sockets and accessories for 60 series relays
Screw terminal (Box clamp) socket 90.82.3 90.82.30 90.83.3 90.83.30
panel or 35 mm rail (EN 60715) mount Blue Black Blue Black
For relay type 60.12 60.13
Accessories
Metal retaining clip 090.33
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.8
Max. wire size for 90.82.3 and 90.83.3 sockets solid wire stranded wire
mm21x6 / 2x4 1x6 / 2x4
AWG 1x10 / 2x14 1x10 / 2x14
90.26
11
90 Series - Sockets and accessories for 60 series relays
Approvals
(according to type):
Screw terminal (Plate clamp) socket 90.26 90.26.0 90.27 90.27.0
panel or 35 mm rail (EN 60715) mount Blue Black Blue Black
For relay type 60.12 60.13
Accessories
Metal retaining clip (supplied with socket - packaging code SMA)
090.33
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.8
Wire strip length mm 10
Max. wire size for 90.26 and 90.27 sockets solid wire stranded wire
mm21x4 / 2x2.5 1x4 / 2x2.5
AWG 1x12 / 2x14 1x12 / 2x14
Approvals
(according to type):
Flange mount solder socket mount with M3 screw 90.12 (black) 90.13 (black)
For relay type 60.12 60.13
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Ambient temperature °C –40…+70
90.12
90.27
90.26
90.14 90.15
12
90 Series - Sockets and accessories for 60 series relays
How to code and identify retaining clip and packaging options for sockets.
Example:
2 1
.
90
Packaging code
AStandard packaging
Without retaining clip
SM Metal retaining clip
SM A
2 1
.
90
PCB socket Blue 90.14 (Ø 20.5 mm) 90.15 (Ø 22 mm)
Blue 90.14.1 (Ø 17.5 mm) 90.15.1 (Ø 19 mm)
For relay type 60.12 60.13
Technical data
Rated values 10 A - 250 V
Dielectric strength 2 kV AC
Ambient temperature °C –40…+70
Approvals
(according to type):
90.15