W24258/LL
- 4 -
AC Characteristics, continued
(VDD = 5V ±10%; VSS = 0V; TA = 0° C to 70° C)
Read Cycle
PARAMETER SYM. W24258-55LL W24258-70LL UNIT
MIN. MAX. MIN. MAX.
Read Cycle Time TRC 55 -70 -nS
Address Access Time TAA -55 -70 nS
Chip Select Access Time TACS -55 -70 nS
Output Enable to Output Valid TAOE -27 -35 nS
Chip Selection to Output in Low Z TCLZ*10 -10 -nS
Output Enable to Output in Low Z TOLZ*5-5-nS
Chip Deselection to Output in High Z TCHZ*-25 -30 nS
Output Disable to Output in High Z TOHZ*-25 -30 nS
Output Hold from Address Change TOH 10 -10 -nS
∗ These parameters are sampled but not 100% tested
Write Cycle
PARAMETER SYM. W24258-55LL W24258-70LL UNIT
MIN. MAX. MIN. MAX.
Write Cycle Time TWC 55 -70 -nS
Chip Selection to End of Write TCW 40 -50 -nS
Address Valid to End of Write TAW 40 -50 -nS
Address Setup Time TAS 0-0-nS
Write Pulse Width TWP 40 -50 -nS
Write Recovery Time
,
TWR 0-0-nS
Data Valid to End of Write TDW 25 -30 -nS
Data Hold from End of Write TDH 0-0-nS
Write to Output in High Z TWHZ*-20 -25 nS
Output Disable to Output in High Z TOHZ*-20 -25 nS
Output Active from End of Write TOW 5-5-nS
∗ These parameters are sampled but not 100% tested