CSM_S3D2_DS_E_7_1
1
Sensor Controller
S3D2
Offers High-speed Input Response of
0.1 ms and Equipped with Built-in
Timer
High-speed response of 0.1 ms.
Ideal as a two-input Controller.
Lineup includes the S3D2-BK with flip-flop functions convenient for
level control, the S3D2-AKD/CKD/CCD with 24-V power supply, and
the S3D2-DK/EK with one input/output OFF-delay (two circuits)
useful for load control and lamp display
Power source for the Sensor can be supplied up to
200 mA.
Ultra-slim body with 30-mm width.
Multi-function model equipped with timer functions also available.
Ordering Information
* Models compatible with Sensors for PNP connections are also available. These model numbers have the suffix B (e.g., S3D2-AKB)
Differences from NPN Models
Note: S3D2-AK(B)/-CK(B)/-CC(B) models with UL certification are available.
These model numbers have the suffix US (e.g., S3D2-AK-US).
Power supply voltage Output Timer function Features Model
100 to 240 VAC Relay
No Single-function with one input/output (two circuits) S3D2-DK
Yes S3D2-EK
No Single-function with two inputs/one output (AND/OR operation) S3D2-AK *
No Flip-flop function with two inputs/one output S3D2-BK
Yes Multi-function with two inputs/one output S3D2-CK *
Transistor Yes S3D2-CC *
24 VDC Relay No Single-function with two inputs/one output S3D2-AKD
Yes Multi-function with two inputs/one output S3D2-CKD
Transistor Yes S3D2-CCD
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 7.
Input signals
ON 8 to 12 V (5 mA min.)
OFF 0 to 4 V (2 mA max.)
Maximum applied voltage 12 V
S3D2
2
Ratings and Specifications
* The timer will not operate in response to input signals received within 50 ms after the Controller power is turned ON.
Type Two inputs/
two outputs Two inputs/one output
Single-
function
Single-func-
tion (with
OFF-delay)
Single-func-
tion (AND/OR
operation)
Flip-flop
function Multi-function
Single-func-
tion (AND/OR
operation)
Multi-function (24 VDC)
Item Model S3D2-DK S3D2-EK S3D2-AK S3D2-BK S3D2-CK S3D2-CC S3D2-AKD S3D2-CKD S3D2-CCD
Rated supply
voltages 100 to 240 VAC ± 10% 50/60Hz 24 VDC ± 10%
Power consumption 15 VA max. 2.5 VA max. (excluding Sensor power supply)
Power supply for
Sensor 12 VDC ± 10% (includes all variations), 200 mA max. (with short-circuit protection) 24 VDC (supplied from power supply)
Connected Sensor NPN transistor output (with sinking current of 18 mA min.) or contact output
Input
signals
ON 0 to 4 V (5 mA min.)
OFF 8 to 12 V (2 mA max.) 8 to 30 V (2 mA max.)
Short-
circuit
current
11 mA TYP (18 mA max.)
Maximum
applied
voltage
30 V
Input response time 0.1 ms IN1 2 ms
IN2 2 ms 0.1 ms
Output minimum
pulse width 10 ms max. 0.5 ms max. 10 ms max. 0.5 ms max.
Control output
Relay output SPST-NO
× 2
250 VAC, 2A (cosφ = 1)
Relay output SPDT (shared common)
250 VAC, 3 A (cosφ = 1)
NPN open
collector output,
30 VDC, 100 mA
(NO, NC)
Residual voltage
(ON)1.5 V max.
Leakage current
(OFF): 0.1 mA max.
Relay output SPDT
250 VAC, 3 A (cosφ = 1)
NPN open
collector output,
30 VDC, 100 mA
(NO, NC)
Residual voltage
(ON): 1.5 V max.
Leakage current
(OFF): 0.1 mA max.
Life ex-
pectan-
cy (relay
output)
Mechanical
50,000,000 operations min. (switching frequency: 18,000 operations/h)
---
50,000,000 operations min.
(switching frequency: 18,000
operations/h)
---
Electrical 100,000 operations min. (switching frequency: 1,800 operations/h)
100,000 operations min.
(switching frequency:
1,800 operations/h)
Output response time 10 ms max. 0.5 ms max. 10 ms max. 0.5 ms max.
Timer functions *---
OFF-delay
0.1 to 1 s
1 to 10 s
selectable
---
One-shot, ON-delay,
and OFF-delay
---
One-shot, ON-delay,
and OFF-delay
0.1 to 1 s
1 to 10 s
selectable
0.01 to 0.1 s
0.1 to 1 s
selectable
0.1 to 1 s
1 to 10 s
selectable
0.01 to 0.1 s
0.1 to 1 s
selectable
Other functions Signal input reverse
Signal input
reverse
AND/OR
operating
mode selec-
tion by wiring
Signal input
reverse
Flip-flop
function
Signal input reverse
Sync mode selection
AND/OR operating mode
selection
Signal input
reverse
AND/OR
operating
mode selec-
tion by wiring
Signal input reverse
Sync mode selection
AND/OR operating mode
selection
Maximum allowable
time of momentary
power failure
20 ms max.
Ambient
temperature range Operating: 10 to +55°C, Storage: 25 to +65°C (with no icing)
Ambient humidity
range Operating/storage: 35% to 85%
Noise immunity Operating power supply: 1,500 V (p-p) min.; pulse width: 100 ns, 1 μs; rise time: 1 ns
Input/output: 1,200 V (p-p) min.; pulse width: 100 ns, 1 μs; rise time: 1 ns
Operating power supply: 480 V (p-p) min.; pulse
width: 100 ns, 1 μs; rise time: 1 ns
Input/output:
1,000 V (p-p) min.; pulse width: 100 ns, 1 μs;
rise time: 1 ns
Dielectric strength 1,500 VAC min.(between power supply terminals and I/O terminals, and between non-cur-
rent-carrying parts)
1,500 VAC min.
(between power supply terminals and non-cur-
rent-carrying parts)
Vibration
(destruction) 10 to 55 Hz, double-amplitude of 0.75 mm for 2 hours each of the X, Y, and Z directions
Weight Approx. 140 g
3
S3D2
Output Circuit Diagrams
Note: Numbers in parentheses indicate terminal pin numbers.
Relay Output Model Open Collector Model
Input Circuit Diagrams
Note: Numbers in parentheses indicate terminal pin numbers.
Connections
Connection Methods
(1), (2): Power supply terminals
(3): FG terminal Ground with a ground resistance of
100 Ω max. in locations subject to
excessive noise.
(4) to (6): Output terminals
(7), (10): Power supply terminals for S3D2-AKD/-CKD/-CCD
Sensors (+24 V), and other models (+12 V)
(9), (12): Power supply terminals for the Sensor (0 V)
(8), (11): Output terminals for the Sensor
Connect the Sensor output lines.
S3D2-AK/-AKD/
-CK/-CKD/-BK
S3D2-DK/-EK
NO
NC
NO
NO
Relay contact
NC (6)
NO (5)
250 VAC 3 A
COM (4)
OUT2 (6)
OUT1 (5)
COM (4)
S3D2-CC/-CCD
NC (6)
NO (5)
30 VDC 100 mA
COM (4)
R
OUT
10 to
18 mA
10 to
18 mA
0 V
+12 V *
IN
(8), (11)
(9), (12)
(7), (10)
0 V
+12 V *
OUT
0 V
+12 V *
IN
0 V
+12 V *
Voltage output sensor S3D2
Sensor
main
circuit
S3D2
main
circuit
820 Ω820 Ω
Sensor
main
circuit
S3D2
main
circuit
Open collector output sensor S3D2
Note: Terminals (7) and (10), and (9) and (12) are
connected internally.
* S3D2-AKD/-CKD/-CCD: +24 V
* S3D2-AKD/-CKD/-CCD: +24 V
INPUT
87 9
1110 12
+12VIN 10V
54 6
COM NONC
21 3
100to240VAC FG
+12VIN 20V
S3D2-CK
SENSOR CONTROLLER
SOURCE:100 to 240VAC 50/60Hz
OUTPUT:3A 250VAC
RESISTIVE LOAD
DC POWER SUPPLY
12VDC 200mA
OUTPUT
OMRON Corpration MADE IN JAPAN
POWER IN 1IN 2 OUT
INPUT
87 9
1110 12
+24VIN 10V
54 6
COM NONC
3
FG
+24VIN 20V
S3D2-CKD
SENSOR CONTROLLER
SOURCE:24VDC±10% 8.0VA
OUTPUT:3A 250VAC
RESISTIVE LOAD
OUTPUT
OMRON Corpration MADE IN JAPAN
POWER IN 1IN 2 OUT
INPUT
87 9
1110 12
+12VIN 10V
54 6
COM NONC
21 3
100to240VAC FG
+12VIN 20V
S3D2-BK
SENSOR CONTROLLER
SOURCE:100 to 240VAC 50/60Hz
OUTPUT:3A 250VAC
RESISTIVE LOAD
DC POWER SUPPLY
12VDC 200mA
OUTPUT
OMRON Corpration MADE IN JAPAN
POWER IN 1IN 2 OUT
INPUT
87 9
1110 12
+12VIN 10V
54 6
COM NONC
21 3
100to240VAC FG
+12VIN 20V
S3D2-AK
SENSOR CONTROLLER
SOURCE:100 to 240VAC 50/60Hz
OUTPUT:3A 250VAC
RESISTIVE LOAD
DC POWER SUPPLY
12VDC 200mA
OUTPUT
OMRON Corpration MADE IN JAPAN
POWER IN 1IN 2 OUT
INPUT
87 9
1110 12
+24VIN 10V
54 6
COM NONC
3
FG
+24VIN 20V
S3D2-AKD
SENSOR CONTROLLER
SOURCE:24VDC±10% 8.0VA
OUTPUT:3A 250VAC
RESISTIVE LOAD
OUTPUT
OMRON Corpration MADE IN JAPAN
POWER IN 1IN 2 OUT
INPUT
87 9
1110 12
+12VIN 10V
54 6
COM NONC
21 3
100to240VAC FG
+12VIN 20V
S3D2-CC
SENSOR CONTROLLER
SOURCE:100 to 240VAC 50/60Hz
OUTPUT:100mA 30VDC
RESISTIVE LOAD
DC POWER SUPPLY
12VDC 200mA
OUTPUT
OMRON Corpration MADE IN JAPAN
POWER IN 1IN 2 OUT
INPUT
87 9
1110 12
+24VIN 10V
54 6
COM NONC
3
FG
+24VIN 20V
S3D2-CCD
SENSOR CONTROLLER
SOURCE:24VDC±10% 8.0VA
OUTPUT:100mA 30VDC
OUTPUT
OMRON Corpration MADE IN JAPAN
POWER IN 1IN 2 OUT
INPUT
87 9
1110 12
+12VIN 10V
54 6
COM OUT1 OUT2
21 3
100to240VAC FG
+12VIN 20V
S3D2-EK
SENSOR CONTROLLER
SOURCE:100 to 240VAC 50/60Hz
OUTPUT:2A 250VAC
RESISTIVE LOAD
DC POWER SUPPLY
12VDC 200mA
OUTPUT
OMRON Corpration MADE IN JAPAN
POWER OUT1 OUT2
21
24VDC
21
24VDC
21
24VDC
S3D2-AK S3D2-CK S3D2-CC S3D2-BK
S3D2-DK/-EK
S3D2-AKD S3D2-CKD S3D2-CCD
S3D2
4
Sensor Connections
Two-wire Sensors (NPN Models)
Note: Numbers in parentheses indicate terminal pin numbers.
Contact Output Sensors
The S3D2 has a high-speed input response of 0.1 ms, which may
cause contact output models (relay output, micro-switches, etc.) to
receive unnecessary input from contact bounce and chattering.
Example of Unconnectable Sensor Model
Wired OR Transistor Output
Note: Numbers in parentheses indicate terminal pin numbers.
Wired OR for “Object Detected” Signals
(e.g., Proximity Sensors with NO Outputs)
The input would be an OR of “object detected” signals using a wired
OR of Sensors that turn ON the output transistor when an object is
detected. The S3D2’s input signal selector switch can be set to
reverse this operation and produce an input that would be an AND
of “object not detected” signals.
Wired OR for “Object Not Detected” Signals
(e.g., Proximity Sensors with NC Outputs)
The input would be an OR of “object not detected” signals using a
wired OR of Sensors that turn ON the output transistor when an
object is not detected. The S3D2’s input signal selector switch can
be set to reverse this operation and produce an input that would be
an AND of “object detected” signals.
Load Connection
Type Proximity Sensor
Model TL-G3D, TL-L100, etc.
Details
Sink current of NPN output:
2 mA max.
(Sensors that cannot switch
18 mA or higher are uncon-
nectable)
Blue
Brown +12 V
(7), (10)
(8), (11)
(9), (12)
IN
0 V
Sensor
main
circuit
S3D2
main
circuit
2 mA max.
12 V
Output
0 V
Connecting Loads to Emitter Side
Note: 1. Numbers in parentheses indicate terminal
numbers.
2. Connect either the NC or NO terminals for the
Emitter common. The solid line indicates the
NC terminal and the broken line indicates the
NO terminal.
Connecting Loads to Collector Side
NC (6)
NO (5)
COM (4)
Load
Load DC
NC (6)
NO (5)
COM (4) Load
DC
5
S3D2
Nomenclature
* Be sure to set the one-shot timer.
No. Name Functions
(1) POWER indicator (green)
Lights when the operating power is turned ON and the Sensor power supply is output.
Not lit when the operating power is turned OFF, or the Sensor power supply is short circuited
(between the +12-V or +24-V terminal and 0-V terminal).
(2) IN1 indicator (red) Lights when the output from the Sensor connected to IN1 is received by IN1 as an input.
(3) IN2 indicator (red) Lights when the output from the Sensor connected to IN2 is received by IN2 as an input.
(4) OUT indicator (red) Lights when the output turns ON.
(5) IN1 input signal selector switch NORM: Input as a signal when the Sensor’s output transistor (or contact output) is ON.
INV: Input as a signal when the Sensor’s output transistor (or contact output) is OFF.
(6) IN2 input signal selector switch
(7) MODE
(AND/OR operation selector switch)
AND: The output is turned ON when IN1 and IN2 input signals are both ON.
OR: The output is turned ON when either IN1 or IN2 input signal is ON.
(8)
SYNC
(synchronous mode selector
switch)
(This switch is enabled only when
the AND/OR operation selector is
set to AND.)
: The output is turned ON while both IN1 and IN2 input signals are ON.
: If the input signal of IN2 is turned ON (at the rising edge) while the IN1 input signal is ON, the
output is turned ON.*
(9) TIMER switch
Turns timer operation ON/OFF.
ON: Timer enabled
OFF: Timer disabled
(10) RANGE
(Timer timing selector switch)
Changes the range for the timer setting time.
S3D2-CK/-EK
1 s: Setting time is in range from 0.1 to 1s.
10 s: Setting time is in range from 1 to 10s.
S3D2-CC
0.1 s: Setting time is in range from 0.01 to 0.1s.
1 s: Setting time is in range from 0.1 to 1s.
(11) TIMER MODE
(Timer operation mode switch)
O. S: One-shot timer
ON. D: ON-delay timer
OFF. D: OFF-delay timer
(12) TIME ADJ.
(Timer setting adjuster)
Setting time can be adjusted with the provided screwdriver.
The adjuster rotates 190°.
(1)
(2)
(5)
(4)
(3)
(6)
(1)
(5)
(2)
(7)
(4)
(6)
(9) (10)
(11) (12)
(3)
(8)
(1)
(2)
(5)
(4)
(3)
(6)
(1)
(5)
(4)
(6)
(1)
(5)
(12)
(4)
(6)
(9)
(10)
S3D2-AK/-AKD S3D2-CK/-CKD/-CC/-CCD S3D2-BK S3D2-DK S3D2-EK
S3D2
6
Operation
Basic Operation
S3D2-CK@/-CC@: Timer Operation (AND)
Note: 1. IN1 and IN2 send OR outputs.
2. IN1 and IN2 send AND outputs.
3. IN1 and IN2 send AND outputs for T seconds from the rising edge.
4. IN1 and IN2 send AND outputs after a delay of T seconds from the
rising edge.
5. IN1 and IN2 send AND outputs for T seconds from the falling edge.
S3D2-DK/-EK: Basic Operation
Two Input Signals Output Independently
The S3D2-EK is equipped with an OFF-delay Timer.
S3D2-DK/-EK: One Sensor with Two Outputs
Terminals (8) and (11) are short-circuited.
Note: 1. The time chart above shows the operation for an S3D2-EK when the
timer 1 switch is OFF and the timer 2 switch is ON.
2. Terminals (8) and (11) are short-circuited, and the current from the
S3D2 to the Sensor is 18 × 2 = 36 mA max. (TYP 22 mA).
S3D2-AK@: Basic Operation
One Sensor
Note: When connecting only one Sensor, be
sure to set the input selector switch for
the unconnected Sensor to INV.
Two Sensors (AND Operation)
Two Sensors (OR Operation)
Note: When two Sensors are wired OR and
then receive input (IN1 or IN2), OR
operation is possible.
S3D2-BK: Flip-flop Operation
Note: ts 2ms, tr 2ms
Input 1 (IN1) takes priority when both
inputs 1 and 2 are received at the
same time.
ON
OFF
ON
OFF
IN1 (NORM)
[IN2 (INV)]
Output
No connection
Brown Black Blu
e
Sensor
NORM INV
IN1 IN2
S3D2-AK/-AKD
789
10 11 12
456
123
ON
OFF
ON
OFF
ON
OFF
IN1 (NORM)
IN2 (NORM)
Output (AND)
Brown
Brown
Black Blu
e
Black
Blue
Sensor 1
Sensor 2
NORM NORM
IN1 IN2
S3D2-AK/-AKD
789
10 11 12
456
123
ON
OFF
ON
OFF
(IN1: Wired OR)
ON
OFF
Sensor 1
Sensor 2
Output (OR)
Brown Black Blu
e
Sensor 2
Sensor 1
NORM INV
IN1 IN2
S3D2-AK/-AKD
789
10 11 12
456
123
S3D2-AK@ default settings: IN1······NORM, IN2······INV.
If AND operation is used, set IN2 to NORM.
ON
OFF
ON
OFF
ON
OFF
IN1 (NORM)
IN2 (NORM)
Output
ts
tr
Brown
Brown
Black Blu
e
Black
Blue
Sensor 1
Sensor 2
NORM NORM
IN1 IN2
S3D2-BK
456
123
789
10 11 12
ON
OFF
ON
OFF
IN1
IN2
TT
T
T
T
(See note 1.)
Output (OR)
(See note 2.)
Output (AND)
(See note 3.)
One-shot output
(AND)
(See note 4.)
ON-delay output
(AND)
(See note 5.)
OFF-delay output
(AND)
When only one Sensor is connected to the S3D2-CK@ and
S3D2-CC@, always set the AND/OR selector switch to
OR .
MODE
AND OR
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Sensor 1
(IN1)
OUT1
OUT2
Sensor 2
(IN2)
Brown
Brown
Black Blue
Black
Blue
Sensor 1
Sensor 2
S3D2-DK
789
10 11 12
456
123
ON
OFF
ON
OFF
ON
OFF
OUT2
OUT1
Sensor 1
T
Brown Black Blue
Sensor
OFF ON
TIMER1 TIMER2
S3D2-EK
789
10 11 12
456
123
7
S3D2
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Be sure to connect the power supply to the power supply terminals
correctly. Use a power supply with a voltage range of 100 to
240 VAC ± 10%.
Do not use the product in atmospheres or environments that exceed
product ratings.
Wiring
Ground
FG is a ground terminal. Ground this terminal at a ground
resistance of 100 Ω max. when installing in locations subject to
excessive noise, or if the S3D2 malfunctions.
Do not share a ground line with other devices, or connect it to a
structural beam of a building. Doing so will have the opposite effect,
and may adversely affect the Sensor.
Storing in a Protective Case
Take measures to provide adequate heat dissipation. Otherwise,
heat radiation from the body of the S3D2 may cause the insides of
protective casing to heat up.
S3D2-AKD/-CKD/-CCD
Do not connect a load of 1 A min. to models for which the S3D2
power supply inputs are to be used as is for the Sensor power
supply outputs. Connecting a load of 1 A min. to the Sensor’s power
supply outputs will cause the fuse in the case to break.
Output
Connect a surge suppressor or diode in parallel to the load if an
inductive load or other electrical part that generates noise is
connected to the output.
Connect the cathode side of the diode to the side of the power
supply.
Output Relay Contact
(Not Including S3D2-CC/-CCD/-DK/-EK)
When using a load (e.g., contactor or valve) that generates an arc
when the circuit is broken, the NC (NO) contact may turn ON before
the NO (NC) contact has opened (turned OFF).
When using both NO and NC outputs at the same time, incorporate
an arc suppressor (use the CR method, varistor, or other
countermeasure).
Mounting
Tightening Torque
Using the provided M3.5 screws, tighten the terminal block to a torque
of 0.59 N·m max.
For direct mounting, use M4 screws, and tighten them to a torque of
0.78 N·m max.
Side-by-side Mounting
When two or more S3D2 are
mounted side by side, be sure
to provide a minimum distance
of 10 mm between them.
Note: Use the PFP-M End Plate for a
space of 10 mm.
If side-by-side mounting is
unavoidable, refer to the following load derating curve.
WARNING
Precautions for Safe Use
Precautions for Correct Use
FG
S3D2
Ground
resistance of
100 Ω
Other device
FG
S3D2 Other device
Terminals (7), (10) 24 V
Terminals (9), (12) 0 V
LoadI < 1 A
L
Relay contact output AC power supply
Surge suppressor
L
Surge suppressor
Resistance: 50 Ω
Capacitor: 0.4 μF
Voltage: 200 V
Relay contact output
Open collector output
DC power supply
Diode
Diode Peak reverse
breakdown voltage is
at least three times
the load voltage.
Average rectified
current: 1 A
S3D2
10 mm
DIN Track
End Plate
(PFP-M)
200
100
010 20 25 30 40 50 55 60
Range in which
side-by-side
mounting is
possible
Ambient temperature (°C)
Load current (mA)
S3D2
8
Always lay the S3D2
input lines, output lines,
and the power line
separately. Otherwise,
malfunction due to
noise may occur.
The power line, through which
a large current flows (e.g., to
drive a motor) should be wired
at least 200 mm away from the
S3D2.
Removing the Terminal Block Cover
Dimensions (Unit: mm)
Output lines
(OUT, 100 to 240 VAC)
Input lines
(IN, IN2, +12 V, 0 V)
S3D2
Provide a distance of 200 mm min.
Power lines
S3D2 Provide a
distance of
200 mm min.
Cover
1. Confirm that the power supply
is turned OFF.
2. Insert your fingers here and lift
up in the direction of the arrow.
S3D2
Two M4 (or 4.3-dia.) hole
s
72±0.3
80
7
75 (no cover)
51.5
78
23.53
30
35.3
(DIN Track mounting is also possible.)
Mounting Holes
(direct mounting)
* Terminal block screws: M3.5
Cat. No. E846-E1-03 In the interest of product improvement, specifications are subject to change without notice.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016
.
9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.