Product datasheet 9012GCW22 Characteristics pressure switch 9012G - adjustable scale - 2 thresholds - 90 to 2900 psig Range of product 9012G Pressure sensor type Electromechanical pressure switch Pressure sensor name 9012G Pressure sensor size 2900 psi Maximum pressure 15000 psi Contacts type and composition 2(NC-NO), DPDT-DB, Form ZZ, snap action, silver nickel contacts Controlled fluid Air Non-corrosive liquids Non-corrosive gas Hydraulic oil (-15...250 F) Fluid connection type 0.25 inch 18 NPTF conforming to UL 508 Pressure switch type of operation Regulation between 2 thresholds Scale type Adjustable Local display Without Complementary Range on decreasing pressure 90...2900 psi Approx differential at mid range 170...560 psi +/- 2.5 % full scale Cable entry 0.5 inch NPT conduit entrance Terminal block type 8 screw terminals Electrical connection Screw-clamp terminals, AWG 22...12 Electrical circuit type Control circuit Local signalling Without [In] rated current 3 A (Ue = 240 V AC) contact code: A600 conforming to NEMA rating designation 6 A (Ue = 120 V AC) contact code: A600 conforming to NEMA rating designation 0.22 A (Ue = 125 V DC) contact code: R300 conforming to NEMA rating designation 0.11 A (Ue = 250 V DC) contact code: R300 conforming to NEMA rating designation Setting Internal Enclosure material Die cast aluminum alloy 380 Pressure actuator Piston Height 6.37 in Depth 2.63 in Width 3.5 in Operating position Any position Materials in contact with fluid Teflon Viton fluorocarbon 440 stainless steel 303 stainless steel Short circuit protection 10 A by gL (cartridge) overload and short-circuit protection Operating rate <= 120 cyc/mn (-10...185 F) Mechanical durability 3000000 cycles Repeat accuracy > 0...< 4 % Product weight 3.25 lb(US) Environment Vibration resistance 2 gn conforming to IEC 68-2-6 (f = 40...150 Hz) Shock resistance 50 gn conforming to IEC 58-2-27 1/2 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Main Standards CE CSA C22-2 No 14 UL 508 Product certifications CE CSA LR25490 class 3211 03 UL listed file E12158 CCN NKPZ and CCN NTHT NEMA degree of protection NEMA 4/4X/13 conforming to UL 50 Ambient air temperature for operation -10...185 F Offer Sustainability Sustainable offer status Green Premium product RoHS Compliant - since 1150 - Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available 2/2