Datasheet SDP3x-Digital Digital Differential Pressure Sensor Smallest size enables portable applications Reflow solderable - Pick & Place Excellent repeatability, no drift, no offset Extended feature set - smart averaging Calibrated and temperature compensated Product Summary The SDP3x sensor family is Sensirion's series of small differential pressure sensors designed for high-volume applications where size is a key requirement. It builds on the next generation CMOSens(R) sensor chip that is at the heart of Sensirion's new differential pressure and flow sensing platform. The digital SDP3x sensor features fast measurement speed, excellent accuracy and long-term stability and has no zero-point drift. Furthermore, it is reflow solderable and provides extended functionality, such as smart averaging, multiple temperature compensation modes, configurable I2C address and interrupts. Benefits of Sensirion's CMOSens(R) Technology High reliability and long-term stability Best signal-to-noise ratio Industry-proven technology with a track record of more than 15 years Designed for mass production High process capability Content 1. Sensor Performance .............................................................. 2 2. Specifications ......................................................................... 3 3. Pin Assignment ...................................................................... 4 4. Measurement Modes ............................................................. 5 5. Digital Interface Description ................................................... 6 6. Package Outline................................................................... 11 7. Soldering.............................................................................. 12 8. Shipping Package ................................................................ 13 9. Ordering Information ............................................................ 13 Revision History............................................................................ 13 Important Notices ......................................................................... 14 Headquarters and Subsidiaries .................................................... 14 www.sensirion.com Version 1 - December 2017 1/14 1. Sensor Performance 1.1 Differential Pressure Specification1 Parameter Measurement range 2 accuracy 3,4 Zero point Span accuracy 3,4 Zero point repeatability 4 Span repeatability 4 Span shift due to temperature variation Offset stability Flow step response time (63) Resolution Calibrated for Media compatibility Calibrated temperature range 1.2 SDP31 - 500 to 500 Pa SDP32 - 125 to 125 Pa (- 2 to 2 inH2O) (-0.5 to 0.5 inH2O) 0.1 Pa 3% of reading 0.03 Pa 0.5% of reading 0.08 Pa 3% of reading 0.025 Pa 0.5% of reading < 0.5% of reading per 10C < 0.5% of reading per 10C < 0.01 Pa/year < 0.01 Pa/year < 3ms 16 bit Air, N2 Air, N2, O2, non-condensing -40 C to +85 C Temperature Specification5 Parameter Measurement range Resolution Accuracy Repeatability Value -40 C to +85 C 16 bit 2 C (-10 C to +60 C) 3 C (-40 C to +85 C) 0.1C 1 Unless otherwise noted, all sensor specifications are valid at 25C with VDD = 3.3 V and absolute pressure = 966 mbar. For other pressure ranges contact Sensirion 3 Includes repeatability 4 Total accuracy/repeatability is a sum of zero-point and span accuracy/repeatability. 5 The measured temperature is the temperature of the bulk silicon in the sensor. This temperature value is not only depending on the gas temperature, but also on the sensor's surroundings. Using the signal to measure solely the gas temperature will need special precautions, such as isolating the sensor from external temperature influences. 2 www.sensirion.com Version 1 - December 2017 2/14 2. Specifications 2.1 Electrical Specifications Parameter Supply Voltage Power-up/down level Supply current Symbol VDD VPOR Condition Min. 2.7 2.3 Typ. 3.3 2.5 3.8 Max. 5.5 2.7 5.5 1.1 1 4 Units V V mA mA uA mA Min. Typ. Max. 25 Units ms 20 ms 400 1000 kHz 2000 2200 Hz Measuring Idle state Sleep mode IDD IRQn driving strength 2.2 Timing Specifications Parameter Power-up time Symbol tPU Soft reset time tSR I2C SCL frequency Update rate differential pressure value Update rate temperature value Measurement time fI2C 2.3 Continuous mode 1800 Continuous mode 112.5 Triggered mode 40 45 50 ms Condition Min. Typ. 1 Max. Units bar bar g Hz Comments Time to sensor ready Time between soft reset command and sensor ready Temperature value is updated at least every 16 pressure values Symbol Pmax Pburst W 3 0.2 Comments Materials Parameter Wetted materials REACH, RoHS 2.5 Condition Mechanical Specifications Parameter Allowable overpressure1 Rated burst pressure Weight 2.4 Comments Glass (silicon nitride, silicon oxide), LCP, green epoxy-based mold compound, epoxy-based resins REACH and RoHS compliant Absolute Maximum Ratings Parameter Supply Voltage VDD Max Voltage on pins SDA, SCL, IRQn Input current on any pin Operating temperature range2 Storage temperature range3 Max. humidity for long term exposure ESD HBM (human body model) Rating -0.3 to 5.5 -0.3 to VDD+0.3 70 -40 to +85 -40 to +85 40C dew point 2 Units V V mA C C kV Allowable overpressure during operation. Refer to the SDP selection guide for pressure dependency of the measured signal. Fast absolute pressure changes on both ports can result in dynamic effects on the sensor signal. For higher overpressures or continuous high overpressures contact Sensirion. 2 For Air and N2. Long term exposure to high temperatures and (high concentrations of) O2 can reduce the product lifetime 3 For long term storage in Tape and Reel refer to the SDP3x handling instructions 1 www.sensirion.com Version 1 - December 2017 3/14 3. Pin Assignment The SDP3x consists of a QFN package with a plastic cap covering the top and providing the pneumatic connections to the sensor. Table 1 shows the pin assignments of the SDP3x-Digital sensor. Pin no. 1 2 3 Description Connect to ground Connect to ground Connect to ground Interrupt output. Active low. Keep 4 IRQn floating when not used. 5 SCL Serial Clock (I2C Interface) 6 GND Connect to ground 7 VDD VDD Supply 8 SDA Bidirectional Serial Data (I2C Interface) 9 ADDR I2C Address selection input. 10 GND Connect to ground 11 GND Connect to ground 12-16 Reserved. Do not connect Table 1: SDP3x-Digital pin assignment (bottom view). 3.1 Name GND GND GND Power Pins (VDD, GND) The power supply pins must be decoupled with a 100 nF capacitor that shall be placed as close to the sensor as possible. 3.2 Serial Clock and Serial Data (SCL, SDA) The SCL and SDA are bidirectional pins of the I2C slave interface. The SCL is the Serial Clock pin and the SDA is the Serial Data pin. For more details about the I2C interface refer to section 5. 3.3 ADDR Pin The SDP3x-Digital supports different I2C addresses. With the ADDR pin an address can be selected. Connecting the ADDR pin to GND selects the default address. Other I2C addresses can be selected with a resistor connected to GND. The maximum tolerance for the resistor is 5%. Do not connect the ADDR pin to VDD. I2C Address (Hex) 0x21 0x22 0x23 3.4 Condition ADDR connected to GND ADDR connected with 1.2kOhm to GND ADDR connected with 2.7kOhm to GND IRQn Pin The IRQn pin indicates whether new measurement results are available. The signal is active low, meaning that when the signal is high there is no new measurement data available. The IRQn will automatically clear to high when a differential pressure value is read out. The IRQn pin will also be set to low after every soft reset or Power on Reset, until a measurement command is sent. When the IRQn signal is not used, the pin should stay unconnected and must not be connected to GND or VDD. 3.5 Die Pad (Center Pad) The die pad or center pad is visible from below and located in the center of the package. It is internally connected to GND and therefore there are no electrical constraints on connecting or not connecting the die pad to GND. For mechanical stability it is recommended to solder the center pad to the PCB. The hole in the middle of the die pad must stay open during and after soldering. www.sensirion.com Version 1 - December 2017 4/14 4. Measurement Modes The SDP3x-Digital is a highly versatile differential pressure sensor and is very flexible regarding the measurement speed. This flexibility not only allows for optimizing the sensor's performance to a specific application, but also for adapting the sensor to different use cases. For example, in one use case the sensor is detecting the smallest and quickest changes, whereas in another mode the sensor can measure in larger intervals while consuming only little energy. 4.1 Continuous Mode vs Triggered Mode In continuous mode the sensor is measuring at the highest speed and writes the measurement values to the I2C results buffer, where the I2C master can read out the value when it requires. For a triggered measurement the sensor is default in an idle state and wakes up when the command is sent. It then powers up the heater and does a measurement. During this time the sensor either stretches the clock or it doesn't acknowledge any I2C read header. When the measurement is finished, the sensor returns to the idle state and makes the measurement result available to be read out. For more details see chapter 5.3.3. Continuous mode Measures continuously Description Measurement speed and Measurement result can be read out rate continuously and at any time, but not faster than 0.5ms. Measurement method Sensor configuration is optimized for speed and accuracy. Recommended use Best used where speed and accuracy are most important. 4.2 Triggered mode Measures once after command is sent Measurement result is available in +/- 45ms after command. Clock stretching is available. Sensor configuration is optimized for low power consumption. Best used where energy consumption is more important than speed. Continuous Mode and `Average till Read' In continuous measurement modes a new measurement result is available every 0.5ms. A new value can be read out every 0.5 ms and the IRQn will go low when a new measurement result is available. If the `average till read' option is chosen, the sensor averages all values (xi) prior to the read out. This has the benefit that the user can read out the sensor at its own desired speed, without losing information, which thus prevents aliasing. During the first 25 ms of averaging the averaged value is obtained as the arithmetic mean. = =1 for < 25 ms When the reading speed is even slower than 25 ms, the sensor will continue to average, but with another algorithm. In this algorithm exponential smoothing is used, with a smoothing factor = 0.05. = + (1 - ) -1 , 0 = , for > 25 ms Where S0 is the arithmetic value after the first 25 ms. Please refer to relevant literature for more information about exponential smoothing. 4.3 Temperature Compensation Modes and Absolute Pressure Dependency The SDP3x is temperature compensated both for differential pressure and for mass flow compensated differential pressure. In use cases where the SDP3x is used to measure mass flow it is advised to use mass flow temperature compensation. In this case no absolute pressure compensation is required. For more information about temperature and absolute pressure compensation for differential pressure sensors, for example volume flow measurements in bypass, refer to the selection guide in the differential pressure download center on our website. www.sensirion.com Version 1 - December 2017 5/14 5. Digital Interface Description The SDP3x-digital interface is compatible with the I2C protocol. This chapter describes the command set for SDP3x-digital. For detailed information about the I2C protocol, please check the document "NXP I2C-bus specification and user manual". 5.1 I2C Address The I2C address for SDP3x-digital can be selected with the ADDR pin. For more information refer to section 3.3. 5.2 I2C Sequences The commands are 16-bit. Data is read from the sensor in multiples of 16-bit words, each followed by an 8-bit checksum to ensure communication reliability. W Cmd[15:8] Cmd[7:0] ACK I2CAdr[6:0] ACK S ACK I2C master writes 16 bit command Data1[15:8] Data1[7:0] CRC1[7:0] ACK R ACK I2CAdr[6:0] ACK S ACK I2C master sends read header and receives multiple 16bit words with CRC byte. P ACK CRC2[7:0] P DataX[7:0] CRCX[7:0] ACK DataX[15:8] ACK or ACK Data2[7:0] ACK Data2[15:8] ACK or P Dark areas with white text indicate that the sensor controls the SDA (Data) line. I2C sequences can be aborted with a NACK and STOP condition. 5.3 I2C Commands The command set of the SDP3x-digital consists of a set of different commands: - Continuous measurement o Start Continuous measurement commands o Stop Continuous measurement command - Triggered measurement commands - Soft reset - Entering and exiting sleep mode - Read product identifier and serial number www.sensirion.com Version 1 - December 2017 6/14 5.3.1 Start Continuous Measurement The sensor measures both the differential pressure and temperature. Both measurement results can be read out through one single I2C read header. Continuous measurements can be started up in different configurations by a set of commands. Command code (Hex) 0x3603 0x3608 0x3615 0x361E Temperature compensation Mass flow Mass flow Differential pressure Differential pressure Averaging Average till read None - Update rate 0.5ms Average till read None - Update rate 0.5ms After one of the commands has been sent, the chip continuously measures and updates the measurement results. New results can be read continuously with only an I2C read header. (Measurement) commands must not be sent until the stop measurement command has been sent. After the start measurement command is sent: - the first measurement result is available after 8ms. - small accuracy deviations (few % of reading) can occur during the next 12ms. When no measurement data is yet available the sensor will respond with a NACK to the I2C read header (I2C address + read bit). Preceding command continuous measurement Consecutive read Description Byte1: Differential Pressure 8msb Byte2: Differential Pressure 8lsb Byte3: CRC Byte4: Temperature 8msb Byte5: Temperature 8lsb Byte6: CRC Byte7: Scale Factor differential pressure 8msb Byte8: Scale Factor differential pressure 8lsb Byte9: CRC After a start continuous measurement command, the measurement results can be read out. The temperature and scale factor don't need to be read out (every time). The read sequence can be aborted by a NACK and a STOP condition. The scale factor is for differential pressure in Pascal. 5.3.2 Stop Continuous Measurement Command Command code (Hex) Stop continuous 0x3FF9 measurement Description This command stops the continuous measurement and puts the sensor in idle mode. It powers off the heater and makes the sensor receptive for another command after 500us. The Stop command is also required when switching between different continuous measurement commands. When the sensor is in continuous measurement mode, the sensor must be stopped before it can accept another command. The only exception is the soft reset command as described in section 5.3.4. In idle mode the sensor will consume less power, but consider the sleep mode for most effective energy saving. www.sensirion.com Version 1 - December 2017 7/14 5.3.3 Triggered Measurement During a triggered measurement the sensor measures both differential pressure and temperature. The measurement starts directly after the command has been sent. The command needs to be repeated with every measurement. Command code (Hex) 0x3624 0x3726 0x362F 0x372D Temperature compensation Mass flow Mass flow Differential pressure Differential pressure Clock stretching Yes Yes During the 45ms that the sensor is measuring, no command can be sent to the sensor. After the 45ms the result can be read out and any command can be sent to the sensor. Monitoring whether or not the sensor is ready with its measurement can be done with the following methods. Method Clock stretching Available Only for clock stretching commands Polling Only for non-clock stretching commands Always IRQn Description The sensor starts the measurement after the triggered measurement command with clock stretching. When an I2C read header is sent within 45ms the sensor performs clock stretching after acknowledging the read header. When the sensor has finished the measurement, it makes the result available by releasing the SCL. In this mode the sensor does not acknowledge (NACK) an I2C read header as long as no measurement result is available. The IRQn is always available to monitor whether the sensor is ready with the measurement. When the IRQn is low, the sensor indicates that a new measurement result can be read out. The IRQn is self-clearing when the result is read-out. When new measurement data is available it can be read out by sending an I 2C read header and reading out the data from the sensor. In the table below the data layout of the results can be found. Preceding command Triggered measurement Consecutive read Description Byte1: Differential Pressure 8msb Byte2: Differential Pressure 8lsb Byte3: CRC Byte4: Temperature 8msb Byte5: Temperature 8lsb Byte6: CRC Byte7: Scale Factor differential pressure 8msb Byte8: Scale Factor differential pressure 8lsb Byte9: CRC After a triggered measurement command, the results can be read out when the sensor is finished with the measurement. The temperature and scale factor don't need to be read out (every time). The read sequence can be aborted by a NACK and a STOP condition. The scale factor is for differential pressure in Pascal. 5.3.4 Soft Reset Command General call reset I2C address + W bit + command code (Hex) 0x0006 Consecutive read NA Description This sequence resets the sensor with a separate reset block, which is as much as possible detached from the rest of the system on chip. Note that the I2C address is 0x00, which is the general call address, and that the command is 8 bit. The reset is implemented according to the I2C specification. After the reset command the sensor will take maximum 20ms to reset. During this time the sensor will not acknowledge its address nor accept commands. www.sensirion.com Version 1 - December 2017 8/14 5.3.5 Entering and Exiting Sleep Mode In sleep mode the sensor uses the minimum amount of current. The mode can only be entered from idle mode, i.e. when the sensor is not measuring. This mode is particularly useful for battery operated devices. To minimize the current in this mode, the complexity of the sleep mode circuit has been reduced as much as possible, which is mainly reflected by the way the sensor exits the sleep mode. In sleep mode the sensor cannot be soft reset. Command Enter Sleep mode Command code (Hex) 0x3677 Consecutive read NA Exit Sleep mode NA NA Description Triggered mode: the sleep command can be sent after the result have been read out and the sensor is in idle mode. Continuous mode: the sleep command can be sent after a stop continuous measurement command has been issued and the sensor is in idle mode. The sensor exits the sleep mode and enters the idle mode when it receives the valid I2C address and a write bit (`0'). Note that the I2C address is not acknowledged. It is necessary to poll the sensor to see whether the sensor has received the address and has woken up. This should take maximum 2ms. 5.3.6 Read Product Identifier During assembly and start-up of the machine it might be required to check some basic parameters in the sensor - for example to check if the correct sensor is integrated. The product identifier and serial number can be read out after sending a sequence of two commands. Command Command code Read product 0x367C identifier 0xE102 Product SDP31 SDP32 www.sensirion.com Consecutive read Byte1: Product number [31:24] Byte2: Product number [23:16] Byte3: CRC Byte4: Product number [15:8] Byte5: Product number [7:0] Byte6: CRC Byte7: Serial number [63:56] Byte8: Serial number [55:48] Byte9: CRC Byte10: Serial number [47:40] Byte11: Serial number [39:32] Byte12: CRC Byte13: Serial number [31:24] Byte14: Serial number [23:16] Byte15: CRC Byte16: Serial number [15:8] Byte17: Serial number [7:0] Byte18: CRC Description Note that both commands need to be preceded with an I2C write header (I2C address + W). The second command returns: - 32 bit unique product and revision number. The number is listed in the table below. Note that the last 8 bits are the revision number and can be subject to change. - 64 bit unique serial number Product number 0x03010101 0x03010201 Version 1 - December 2017 9/14 5.4 Checksum Calculation The checksum byte is generated by a CRC algorithm with the following properties: Property Name Protected data Width Polynomial Initialization Reflect input Reflect output Final XOR Example 5.5 Value CRC-8 read data 8 bit 0x31 (x8 + x5 + x4 +1) 0xFF False False 0x00 CRC(0xBEEF) = 0x92 Conversion to Physical Values Conversion of the differential pressure and temperature sensor signals to a physical value is done with the scale factor. 5.5.1 Scale Factors Parameter Differential Pressure (Pascal) Differential Pressure (inches H2O) Temperature SDP31 60 Pa-1 14'945 (inH2O)-1 200 C-1 SDP32 240 Pa-1 59'780 (inH2O)-1 200 C-1 5.5.2 Differential Pressure The digital calibrated differential pressure signal read from the sensor is a signed integer number (two's complement number). The integer value can be converted to the physical value by dividing it by the scale factor. differential pressure = sensor output scale factor 5.5.3 Temperature The digital calibrated temperature signal read from the sensor is a signed integer number (two's complement number). The integer value can be converted to the physical value by dividing it by the scale factor. temperature in C = sensor output scale factor www.sensirion.com Version 1 - December 2017 10/14 6. Package Outline Figure 1: SDP3x. All dimensions in mm. www.sensirion.com Version 1 - December 2017 11/14 7. Soldering Recommended land pattern The solder mask is understood to be the insulating layer on top of the PCB covering the copper traces. It is recommended to design the land pattern as a Non- Solder Mask Defined (NSMD) type. Recommended stencil aperture The sensor must enter the reflow process only once, with a minimal temperature and exposure time. When both sides of the PCB are reflow soldered or multiple reflow runs are required, the sensor must be soldered in the last soldering run. In any case the temperature should not exceed 260C; temperatures above 200C should be limited in time to a maximum of 150 seconds. Ensure that the ports of the sensor are well protected during assembly and soldering so that no dust, solder flux or other liquids can enter the flow channel. In no case, a board wash shall be applied. It is strongly recommended to use "no-clean" solder paste. It is important to note that the diced edge or side faces of the I/O pads may oxidize over time, therefore a solder fillet may or may not form. Hence there is no guarantee for solder joint fillet heights of any kind. Refer to the SDP3x handling instructions on our website for more details. www.sensirion.com Version 1 - December 2017 12/14 8. Shipping Package SDP3x are provided in tape & reel shipment packaging. Standard packaging size is 1500 or 250 units per reel. The drawing of the packaging tapes with sensor orientation is shown in Figure 2. Figure 2: Packaging tape and sensor orientation. Header tape is to the right and trailer tape to the left on this drawing 9. Ordering Information Use the part names and product numbers shown in the following table when ordering SDP3x differential pressure sensor. For the latest product information and local distributors, visit www.sensirion.com. Part name Description / Output SDP31 I2C, 500Pa SDP32 I2C, 125Pa Product number Packaging Tape & Reel size 1-101445-02 Tape & Reel (QFN Quad 2 configuration) 1500 1-101567-02 Tape & Reel (QFN Quad 2 configuration) 250 1-101498-02 Tape & Reel (QFN Quad 2 configuration) 1500 1-101570-02 Tape & Reel (QFN Quad 2 configuration) 250 Revision History Date Author Version Changes 01.12.2017 ANB www.sensirion.com V1 Released. New chip revision. Voltage range extended to 2.7 to 5.5V. Update frequency increased to 0.5ms. Sleep mode added. Product number and identifier updated. Version 1 - December 2017 13/14 Important Notices Warning, personal injury Do not use this product as safety or emergency stop devices or in any other application where failure of the product could result in personal injury (including death). Do not use this product for applications other than its intended and authorized use. Before installing, handling, using or servicing this product, please consult the datasheet and application notes. Failure to comply with these instructions could result in death or serious injury. If the Buyer shall purchase or use SENSIRION products for any unintended or unauthorized application, Buyer shall defend, indemnify and hold harmless SENSIRION and its officers, employees, subsidiaries, affiliates and distributors against all claims, costs, damages and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if SENSIRION shall be allegedly negligent with respect to the design or the manufacture of the product. ESD Precautions The inherent design of this component causes it to be sensitive to electrostatic discharge (ESD). To prevent ESD-induced damage and/or degradation, take customary and statutory ESD precautions when handling this product. See application note "Handling Instructions" for more information. Warranty SENSIRION warrants solely to the original purchaser of this product for a period of 12 months (one year) from the date of delivery that this product shall be of the quality, material and workmanship defined in SENSIRION's published specifications of the product. Within such period, if proven to be defective, SENSIRION shall repair and/or replace this product, in SENSIRION's discretion, free of charge to the Buyer, provided that: notice in writing describing the defects shall be given to SENSIRION within fourteen (14) days after their appearance; such defects shall be found, to SENSIRION's reasonable satisfaction, to have arisen from SENSIRION's faulty design, material, or workmanship; the defective product shall be returned to SENSIRION's factory at the Buyer's expense; and the warranty period for any repaired or replaced product shall be limited to the unexpired portion of the original period. This warranty does not apply to any equipment which has not been installed and used within the specifications recommended by SENSIRION for the intended and proper use of the equipment. EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH HEREIN, SENSIRION MAKES NO WARRANTIES, EITHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT. ANY AND ALL WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY EXCLUDED AND DECLINED. SENSIRION is only liable for defects of this product arising under the conditions of operation provided for in the datasheet and proper use of the goods. SENSIRION explicitly disclaims all warranties, express or implied, for any period during which the goods are operated or stored not in accordance with the technical specifications. SENSIRION does not assume any liability arising out of any application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. All operating parameters, including without limitation recommended parameters, must be validated for each customer's applications by customer's technical experts. Recommended parameters can and do vary in different applications. SENSIRION reserves the right, without further notice, (i) to change the product specifications and/or the information in this document and (ii) to improve reliability, functions and design of this product. Copyright (c) 2016-2017, SENSIRION. CMOSens(R) is a trademark of Sensirion All rights reserved Headquarters and Subsidiaries Sensirion AG Laubisruetistr. 50 CH-8712 Staefa ZH Switzerland Sensirion Inc., USA phone: +1 312 690 5858 info-us@sensirion.com www.sensirion.com Sensirion Korea Co. Ltd. phone: +82 31 337 7700~3 info-kr@sensirion.com www.sensirion.co.kr phone: +41 44 306 40 00 fax: +41 44 306 40 30 info@sensirion.com www.sensirion.com Sensirion Japan Co. Ltd. phone: +81 3 3444 4940 info-jp@sensirion.com www.sensirion.co.jp Sensirion China Co. Ltd. phone: +86 755 8252 1501 info-cn@sensirion.com www.sensirion.com.cn Sensirion Taiwan Co. Ltd phone: +886 3 5506701 info@sensirion.com www.sensirion.com To find your local representative, please visit www.sensirion.com/distributors www.sensirion.com Version 1 - December 2017 14/14