https://www.phoenixcontact.com/us/products/2814731 Current transducers-MCR-S-1-5-UI-SW-DCI-NC-2814731 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR current transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0 ... 0.2 A to 0 ... 11 A, unconfigured Your advantages Device can be set via DIP switches or MCR/PI-CONF-WIN configuration software 3-way isolation True r.m.s. value measurement Key Commercial Data Packing unit 1 pc GTIN GTIN 4017918169282 Weight per Piece (excluding packing) 207.100 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm 01/17/2021Page1/7 https://www.phoenixcontact.com/us/products/2814731 Current transducers-MCR-S-1-5-UI-SW-DCI-NC-2814731 Technical data Ambient conditions Ambient temperature (operation) -20 C ... 60 C Ambient temperature (storage/transport) -40 C ... 85 C Maximum altitude < 2000 m Degree of protection IP20 Noise immunity EN 61000-6-2 Input data Input Current measuring input Number of inputs 3 Configurable/programmable Yes, unconfigured Input current range 0 A ... 11 A (AC/DC) Operate threshold 2 % (of measuring range nominal value 1/5/10 A) Setting range for min. input current 0 A ... 200 mA Setting range for max. input current 0 A ... 11 A Impulse form AC, DC or distorted currents Overload capacity 2 x IN (continuous) Surge strength 20 x IN (1 s) Frequency measuring range 15 Hz ... 400 Hz Connection method Screw connection Output data Output name Voltage output / current output Configurable/programmable Yes, unconfigured Voltage output signal 0 V ... 10 V 2 V ... 10 V -10 V ... 10 V 0 V ... 5 V 1 V ... 5 V -5 V ... 5 V 10 V ... 0 V 10 V ... 2 V 10 V ... -10 V 5 V ... 0 V 5 V ... 1 V 5 V ... -5 V Current output signal 0 mA ... 20 mA 4 mA ... 20 mA 20 mA ... 0 mA 01/17/2021Page2/7 https://www.phoenixcontact.com/us/products/2814731 Current transducers-MCR-S-1-5-UI-SW-DCI-NC-2814731 Technical data Output data 20 mA ... 4 mA Load/output load voltage output > 10 k Load/output load current output < 500 Switching output Output name Relay output Contact type 1 PDT Contact material AgSnO, hard gold-plated Maximum switching voltage 30 VAC 36 VDC 250 VAC (when the gold layer is destroyed) Limiting continuous current 50 mA 2 A (when the gold layer is destroyed) Output name Transistor output, pnp Output voltage range 19 V ... 29 V (supply voltage - 1 V) Continuous load current 80 mA (Not short-circuit proof) Setting range of the threshold value 1 % ... 110 % Setting range of the response delay 0.1 s ... 20 s Status display Yellow LED Power supply Supply voltage range 20 VDC ... 30 VDC Max. current consumption < 50 mA (without load) Connection data Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm ... 2.5 mm Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section AWG 24 ... 14 General Maximum transmission error < 0.5 % (of nominal range value under nominal conditions) Temperature coefficient, typical < 0.025 %/K Step response (10-90%) 330 ms (with AC) 40 ms (with DC) Status display Green LED Overvoltage category III 01/17/2021Page3/7 https://www.phoenixcontact.com/us/products/2814731 Current transducers-MCR-S-1-5-UI-SW-DCI-NC-2814731 Technical data General Degree of pollution 2 Rated insulation voltage 300 VAC (to earth) Test voltage input/output 4 kV (50 Hz, 1 min.) Test voltage input/power supply 4 kV (50 Hz, 1 min.) Test voltage output/power supply 500 V (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Color green Housing material Polyamide PA non-reinforced Mounting position any Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Connection in acc. with standard CUL Low Voltage Directive Conformance with Low Voltage Directive Conformance CE-compliant UL, USA/Canada Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only Conformance/approvals Designation CE Identification CE-compliant Designation UL, USA/Canada Identification Class I, Zone 2, AEx nA nC IIC T4, Ex nA nC IIC T4 Gc X Class I, Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings 01/17/2021Page4/7 https://www.phoenixcontact.com/us/products/2814731 Current transducers-MCR-S-1-5-UI-SW-DCI-NC-2814731 Dimensional drawing Dimensional drawing 22,5 99 22,5 114,5 114,5 99 Circuit diagram 5 6 7 12 1 11 2 14 3 NC 4 OUT DAC C SPAN 8 IN ADC SET TIME POINT ZERO 10A 5A 1A OUT I DAC U Po wer = 9 O UT I 10 O UT U 11 GND 2 12 GND 2 13 24VDC 14 GND 1 15 SW 16 GND 1 Classifications eCl@ss eCl@ss 10.0.1 27210123 eCl@ss 11.0 27210123 eCl@ss 4.0 27271100 eCl@ss 4.1 27200300 eCl@ss 5.0 27200300 eCl@ss 5.1 27200300 eCl@ss 6.0 27210100 eCl@ss 7.0 27210123 eCl@ss 8.0 27210123 eCl@ss 9.0 27210123 ETIM ETIM 3.0 EC002475 ETIM 4.0 EC002475 ETIM 5.0 EC002475 ETIM 6.0 EC002475 ETIM 7.0 EC002475 01/17/2021Page5/7 https://www.phoenixcontact.com/us/products/2814731 Current transducers-MCR-S-1-5-UI-SW-DCI-NC-2814731 Classifications UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121032 UNSPSC 18.0 39121032 UNSPSC 19.0 39121032 UNSPSC 20.0 39121032 UNSPSC 21.0 39121032 Approvals Approvals Approvals UL Recognized / cUL Recognized / EAC / cULus Recognized Ex Approvals UL Listed / cUL Listed / cULus Listed Approval details UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 238705 EAC RU*DE.*08.B.01852-19 cULus Recognized 01/17/2021Page6/7 https://www.phoenixcontact.com/us/products/2814731 Current transducers-MCR-S-1-5-UI-SW-DCI-NC-2814731 Accessories Accessories Arrester test system Cable-CM-KBL-RS232/USB-2881078 Connecting cable D-9-SUB to USB, with adapter D-9-SUB to D-25-SUB. Programming adapter Adapter cable-MCR-TTL-RS232-E-2814388 Software adapter cable (Stereo jack connector/D-SUB 25-pos.), 1.2 m length, for programming MCR-T-..., MCR-S-... and MCR-f-... modules Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 01/17/2021Page7/7